BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

197 related articles for article (PubMed ID: 22051137)

  • 1. Influence of in vitro hemolysis on hematological testing on Advia 2120.
    Lippi G; Musa R; Avanzini P; Aloe R; Pipitone S; Sandei F
    Int J Lab Hematol; 2012 Apr; 34(2):179-84. PubMed ID: 22051137
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Influence of mechanical hemolysis of blood on two D-dimer immunoassays.
    Lippi G; Avanzini P; Zobbi V; Ippolito L
    Blood Coagul Fibrinolysis; 2012 Jul; 23(5):461-3. PubMed ID: 22576291
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Influence of mechanical trauma of blood and hemolysis on PFA-100 testing.
    Lippi G; Fontana R; Avanzini P; Aloe R; Ippolito L; Sandei F; Favaloro EJ
    Blood Coagul Fibrinolysis; 2012 Jan; 23(1):82-6. PubMed ID: 22123286
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Studies on in vitro hemolysis and utility of corrective formulas for reporting results on hemolyzed specimens.
    Lippi G; Avanzini P; Pavesi F; Bardi M; Ippolito L; Aloe R; Favaloro EJ
    Biochem Med (Zagreb); 2011; 21(3):297-305. PubMed ID: 22420244
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Identification of spurious hemolysis in anticoagulated blood with Sysmex XE-2100 and Siemens Advia 2120.
    Lippi G; Pipitone S; Gennari D; Franchini M
    Clin Lab; 2012; 58(7-8):801-4. PubMed ID: 22997981
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Interference of in vitro hemolysis complete blood count.
    de Jonge G; Dos Santos TL; Cruz BR; Simionatto M; Bittencourt JIM; Krum EA; Moss MF; Borato DCK
    J Clin Lab Anal; 2018 Jun; 32(5):e22396. PubMed ID: 29396875
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Venous stasis and routine hematologic testing.
    Lippi G; Salvagno GL; Montagnana M; Franchini M; Guidi GC
    Clin Lab Haematol; 2006 Oct; 28(5):332-7. PubMed ID: 16999725
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Scoring system for detecting spurious hemolysis in anticoagulated blood specimens.
    Yoo G; Kim J; Uh Y; Yoon KR; Park SD; Yoon KJ
    Ann Lab Med; 2015 May; 35(3):341-7. PubMed ID: 25932443
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Influence of in vitro hemolysis on nucleated red blood cells and reticulocyte counts.
    Lippi G; Pavesi F; Cattabiani C; Avanzini P; Pipitone S
    Int J Lab Hematol; 2013 Apr; 35(2):225-8. PubMed ID: 23033911
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Influence of hemolysis on troponin testing: studies on Beckman Coulter UniCel Dxl 800 Accu-TnI and overview of the literature.
    Lippi G; Avanzini P; Dipalo M; Aloe R; Cervellin G
    Clin Chem Lab Med; 2011 Sep; 49(12):2097-100. PubMed ID: 21892912
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Correction of factitious hyperkalemia in hemolyzed specimens.
    Owens H; Siparsky G; Bajaj L; Hampers LC
    Am J Emerg Med; 2005 Nov; 23(7):872-5. PubMed ID: 16291444
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Spurious hemolysis does not influence the reliability of digoxin testing on Siemens RXL MAX and Roche Cobas e601.
    Lippi G; Mercadanti M; Romero A; Lipreri G; Salvagno GL; Guidi GC
    Ann Clin Lab Sci; 2012; 42(3):302-6. PubMed ID: 22964619
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Stability of hematological analytes depends on the hematology analyser used: a stability study with Bayer Advia 120, Beckman Coulter LH 750 and Sysmex XE 2100.
    Imeri F; Herklotz R; Risch L; Arbetsleitner C; Zerlauth M; Risch GM; Huber AR
    Clin Chim Acta; 2008 Nov; 397(1-2):68-71. PubMed ID: 18706900
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Performance evaluation of the Sysmex pocH-100i automated hematology analyzer.
    Whisler S; Dahlgren C
    Lab Hematol; 2005; 11(2):107-17. PubMed ID: 16024334
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Development of simple equations for effective screening of spurious hemolysis in whole-blood specimens.
    Lippi G; Pavesi F; Avanzini P; Chetta F; Aloe R; Pipitone S
    Int J Lab Hematol; 2015 Apr; 37(2):253-8. PubMed ID: 25041897
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Multicenter evaluation of the hemolysis index in automated clinical chemistry systems.
    Lippi G; Luca Salvagno G; Blanckaert N; Giavarina D; Green S; Kitchen S; Palicka V; Vassault AJ; Plebani M
    Clin Chem Lab Med; 2009; 47(8):934-9. PubMed ID: 19548845
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Stability of blood cell counts, hematologic parameters and reticulocytes indexes on the Advia A120 hematologic analyzer.
    Lippi G; Salvagno GL; Solero GP; Franchini M; Guidi GC
    J Lab Clin Med; 2005 Dec; 146(6):333-40. PubMed ID: 16310516
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Preanalytical treatment of EDTA-anticoagulated blood to ensure stabilization of the mean platelet volume and component measured with the ADVIA counters.
    Diaz-Ricart M; Brunso L; Pino M; Navalon F; Jou JM; Heras M; White JG; Escolar G
    Thromb Res; 2010 Jul; 126(1):e30-5. PubMed ID: 20427079
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Influence of hemolysis on routine clinical chemistry testing.
    Lippi G; Salvagno GL; Montagnana M; Brocco G; Guidi GC
    Clin Chem Lab Med; 2006; 44(3):311-6. PubMed ID: 16519604
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Stability and reproducibility of ADVIA 120-measured red blood cell and platelet parameters in dogs, cats, and horses, and the use of reticulocyte haemoglobin content (CH(R)) in the diagnosis of iron deficiency.
    Prins M; van Leeuwen MW; Teske E
    Tijdschr Diergeneeskd; 2009 Apr; 134(7):272-8. PubMed ID: 19431960
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.