170 related articles for article (PubMed ID: 22052018)
21. Reproducibility of RTVue retinal nerve fiber layer thickness and optic disc measurements and agreement with Stratus optical coherence tomography measurements.
González-García AO; Vizzeri G; Bowd C; Medeiros FA; Zangwill LM; Weinreb RN
Am J Ophthalmol; 2009 Jun; 147(6):1067-74, 1074.e1. PubMed ID: 19268891
[TBL] [Abstract][Full Text] [Related]
22. Reproducibility of retinal nerve fiber thickness measurements using the stratus OCT in normal and glaucomatous eyes.
Budenz DL; Chang RT; Huang X; Knighton RW; Tielsch JM
Invest Ophthalmol Vis Sci; 2005 Jul; 46(7):2440-3. PubMed ID: 15980233
[TBL] [Abstract][Full Text] [Related]
23. Quantitative assessment of retinal nerve fiber layer defect depth using spectral-domain optical coherence tomography.
Suh MH; Yoo BW; Kim JY; Choi YJ; Park KH; Kim HC
Ophthalmology; 2014 Jul; 121(7):1333-40. PubMed ID: 24612980
[TBL] [Abstract][Full Text] [Related]
24. Potential of stratus optical coherence tomography for detecting early glaucoma in perimetrically normal eyes of open-angle glaucoma patients with unilateral visual field loss.
Zhang Y; Wu LL; Yang YF
J Glaucoma; 2010 Jan; 19(1):61-5. PubMed ID: 20075675
[TBL] [Abstract][Full Text] [Related]
25. The effects of peripapillary atrophy on the diagnostic ability of Stratus and Cirrus OCT in the analysis of optic nerve head parameters and disc size.
Kim SY; Park HY; Park CK
Invest Ophthalmol Vis Sci; 2012 Jul; 53(8):4475-84. PubMed ID: 22618588
[TBL] [Abstract][Full Text] [Related]
26. Factors associated with variability in retinal nerve fiber layer thickness measurements obtained by optical coherence tomography.
Wu Z; Vazeen M; Varma R; Chopra V; Walsh AC; LaBree LD; Sadda SR
Ophthalmology; 2007 Aug; 114(8):1505-12. PubMed ID: 17367862
[TBL] [Abstract][Full Text] [Related]
27. Glaucoma diagnostic ability of quadrant and clock-hour neuroretinal rim assessment using cirrus HD optical coherence tomography.
Hwang YH; Kim YY
Invest Ophthalmol Vis Sci; 2012 Apr; 53(4):2226-34. PubMed ID: 22410556
[TBL] [Abstract][Full Text] [Related]
28. Screening for glaucoma in high-risk populations using optical coherence tomography.
Li G; Fansi AK; Boivin JF; Joseph L; Harasymowycz P
Ophthalmology; 2010 Mar; 117(3):453-61. PubMed ID: 20031231
[TBL] [Abstract][Full Text] [Related]
29. Three-dimensional imaging of the macular retinal nerve fiber layer in glaucoma with spectral-domain optical coherence tomography.
Sakamoto A; Hangai M; Nukada M; Nakanishi H; Mori S; Kotera Y; Inoue R; Yoshimura N
Invest Ophthalmol Vis Sci; 2010 Oct; 51(10):5062-70. PubMed ID: 20463326
[TBL] [Abstract][Full Text] [Related]
30. Comparison of optic nerve head topography and retinal nerve fiber layer in eyes with narrow angles versus eyes from a normal open angle cohort - a pilot study.
Chen YC; Huang G; Kasuga T; Porco T; Hung PT; Lee R; Lin SC
Curr Eye Res; 2012 Jul; 37(7):592-8. PubMed ID: 22559281
[TBL] [Abstract][Full Text] [Related]
31. Retinal nerve fiber layer imaging with spectral-domain optical coherence tomography a study on diagnostic agreement with Heidelberg Retinal Tomograph.
Leung CK; Ye C; Weinreb RN; Cheung CY; Qiu Q; Liu S; Xu G; Lam DS
Ophthalmology; 2010 Feb; 117(2):267-74. PubMed ID: 19969364
[TBL] [Abstract][Full Text] [Related]
32. Glaucoma detection using different Stratus optical coherence tomography protocols.
Hougaard JL; Heijl A; Bengtsson B
Acta Ophthalmol Scand; 2007 May; 85(3):251-6. PubMed ID: 17343690
[TBL] [Abstract][Full Text] [Related]
33. Effect of lowering intraocular pressure on optical coherence tomography measurement of peripapillary retinal nerve fiber layer thickness.
Chang PT; Sekhon N; Budenz DL; Feuer WJ; Park PW; Anderson DR
Ophthalmology; 2007 Dec; 114(12):2252-8. PubMed ID: 17466378
[TBL] [Abstract][Full Text] [Related]
34. Comparison of glaucoma diagnostic Capabilities of Cirrus HD and Stratus optical coherence tomography.
Park SB; Sung KR; Kang SY; Kim KR; Kook MS
Arch Ophthalmol; 2009 Dec; 127(12):1603-9. PubMed ID: 20008715
[TBL] [Abstract][Full Text] [Related]
35. Comparison of retinal nerve fiber layer thickness and optic disk algorithms with optical coherence tomography to detect glaucoma.
Manassakorn A; Nouri-Mahdavi K; Caprioli J
Am J Ophthalmol; 2006 Jan; 141(1):105-115. PubMed ID: 16386983
[TBL] [Abstract][Full Text] [Related]
36. Optic disc hemorrhage may be associated with retinal nerve fiber loss in otherwise normal eyes.
Jeoung JW; Park KH; Kim JM; Kang SH; Kang JH; Kim TW; Kim DM
Ophthalmology; 2008 Dec; 115(12):2132-40. PubMed ID: 19041474
[TBL] [Abstract][Full Text] [Related]
37. Early glaucoma detection using the Humphrey Matrix Perimeter, GDx VCC, Stratus OCT, and retinal nerve fiber layer photography.
Hong S; Ahn H; Ha SJ; Yeom HY; Seong GJ; Hong YJ
Ophthalmology; 2007 Feb; 114(2):210-5. PubMed ID: 17270671
[TBL] [Abstract][Full Text] [Related]
38. Sensitivity and specificity of time-domain versus spectral-domain optical coherence tomography in diagnosing early to moderate glaucoma.
Chang RT; Knight OJ; Feuer WJ; Budenz DL
Ophthalmology; 2009 Dec; 116(12):2294-9. PubMed ID: 19800694
[TBL] [Abstract][Full Text] [Related]
39. Color-code agreement among stratus, cirrus, and spectralis optical coherence tomography in relapsing-remitting multiple sclerosis with and without prior optic neuritis.
Rebolleda G; González-López JJ; Muñoz-Negrete FJ; Oblanca N; Costa-Frossard L; Álvarez-Cermeño JC
Am J Ophthalmol; 2013 May; 155(5):890-7. PubMed ID: 23398979
[TBL] [Abstract][Full Text] [Related]
40. Translating data and measurements from stratus to cirrus OCT in glaucoma patients and healthy subjects.
Chiseliţă D; Pantalon AD; Cantemir A; Gălăţanu C
Rom J Ophthalmol; 2016; 60(3):158-164. PubMed ID: 29450341
[No Abstract] [Full Text] [Related]
[Previous] [Next] [New Search]