BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

150 related articles for article (PubMed ID: 22056810)

  • 1. Comparison of algorithms for out-of-plane artifacts removal in digital tomosynthesis reconstructions.
    Bliznakova K; Bliznakov Z; Buliev I
    Comput Methods Programs Biomed; 2012 Jul; 107(1):75-83. PubMed ID: 22056810
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A comparison of reconstruction algorithms for C-arm mammography tomosynthesis.
    Rakowski JT; Dennis MJ
    Med Phys; 2006 Aug; 33(8):3018-32. PubMed ID: 16964880
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A comparative study of limited-angle cone-beam reconstruction methods for breast tomosynthesis.
    Zhang Y; Chan HP; Sahiner B; Wei J; Goodsitt MM; Hadjiiski LM; Ge J; Zhou C
    Med Phys; 2006 Oct; 33(10):3781-95. PubMed ID: 17089843
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Evaluation of digital breast tomosynthesis reconstruction algorithms using synchrotron radiation in standard geometry.
    Bliznakova K; Kolitsi Z; Speller RD; Horrocks JA; Tromba G; Pallikarakis N
    Med Phys; 2010 Apr; 37(4):1893-903. PubMed ID: 20443511
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Importance of point-by-point back projection correction for isocentric motion in digital breast tomosynthesis: relevance to morphology of structures such as microcalcifications.
    Chen Y; Lo JY; Dobbins JT
    Med Phys; 2007 Oct; 34(10):3885-92. PubMed ID: 17985634
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Digital tomosynthesis: technique.
    Yaffe MJ; Mainprize JG
    Radiol Clin North Am; 2014 May; 52(3):489-97. PubMed ID: 24792651
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Comparison study of reconstruction algorithms for prototype digital breast tomosynthesis using various breast phantoms.
    Kim YS; Park HS; Lee HH; Choi YW; Choi JG; Kim HH; Kim HJ
    Radiol Med; 2016 Feb; 121(2):81-92. PubMed ID: 26383027
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A comparison of reconstruction algorithms for breast tomosynthesis.
    Wu T; Moore RH; Rafferty EA; Kopans DB
    Med Phys; 2004 Sep; 31(9):2636-47. PubMed ID: 15487747
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Optimization of the acquisition geometry in digital tomosynthesis of the breast.
    Sechopoulos I; Ghetti C
    Med Phys; 2009 Apr; 36(4):1199-207. PubMed ID: 19472626
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Multigrid reconstruction with block-iterative updates for breast tomosynthesis.
    Michielsen K; Nuyts J
    Med Phys; 2015 Nov; 42(11):6537-48. PubMed ID: 26520744
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Implementation and evaluation of an expectation maximization reconstruction algorithm for gamma emission breast tomosynthesis.
    Gong Z; Klanian K; Patel T; Sullivan O; Williams MB
    Med Phys; 2012 Dec; 39(12):7580-92. PubMed ID: 23231306
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Characterization of a constrained paired-view technique in iterative reconstruction for breast tomosynthesis.
    Wu G; Mainprize JG; Yaffe MJ
    Med Phys; 2013 Oct; 40(10):101901. PubMed ID: 24089903
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A method for selective removal of out-of-plane structures in digital tomosynthesis.
    Kolitsi Z; Panayiotakis G; Pallikarakis N
    Med Phys; 1993; 20(1):47-50. PubMed ID: 8455511
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A computer simulation platform for the optimization of a breast tomosynthesis system.
    Zhou J; Zhao B; Zhao W
    Med Phys; 2007 Mar; 34(3):1098-109. PubMed ID: 17441255
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Voting strategy for artifact reduction in digital breast tomosynthesis.
    Wu T; Moore RH; Kopans DB
    Med Phys; 2006 Jul; 33(7):2461-71. PubMed ID: 16898449
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Evaluation of time-efficient reconstruction methods in digital breast tomosynthesis.
    Svahn TM; Houssami N
    Radiat Prot Dosimetry; 2015 Jul; 165(1-4):331-6. PubMed ID: 25855075
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Task-based performance analysis of FBP, SART and ML for digital breast tomosynthesis using signal CNR and Channelised Hotelling Observers.
    Van de Sompel D; Brady SM; Boone J
    Med Image Anal; 2011 Feb; 15(1):53-70. PubMed ID: 20713313
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Evaluation of back projection methods for breast tomosynthesis image reconstruction.
    Zhou W; Lu J; Zhou O; Chen Y
    J Digit Imaging; 2015 Jun; 28(3):338-45. PubMed ID: 25384538
    [TBL] [Abstract][Full Text] [Related]  

  • 19. New reconstruction algorithm for digital breast tomosynthesis: better image quality for humans and computers.
    Rodriguez-Ruiz A; Teuwen J; Vreemann S; Bouwman RW; van Engen RE; Karssemeijer N; Mann RM; Gubern-Merida A; Sechopoulos I
    Acta Radiol; 2018 Sep; 59(9):1051-1059. PubMed ID: 29254355
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A novel pre-processing technique for improving image quality in digital breast tomosynthesis.
    Kim H; Lee T; Hong J; Sabir S; Lee JR; Choi YW; Kim HH; Chae EY; Cho S
    Med Phys; 2017 Feb; 44(2):417-425. PubMed ID: 28032909
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.