These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

161 related articles for article (PubMed ID: 2206716)

  • 1. Cardiac catheterisation with 5 French catheters.
    O'Sullivan JJ; McDonald K; Crean PA; Walsh MJ; McCarthy C; Erwin RJ; Maurer BJ
    Br Heart J; 1990 Sep; 64(3):211-3. PubMed ID: 2206716
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [Systematic use of 4 French catheters for left heart catheterization and coronary angiographies].
    Meyer P; Gervais A; Touati C
    Arch Mal Coeur Vaiss; 1997 Jan; 90(1):35-40. PubMed ID: 9137713
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A prospective randomized study of 4.1 French catheters utilizing the percutaneous right brachial approach for the diagnosis of coronary artery disease.
    Talley JD; Smith SM; Walton-Shirley M; Hattel L; Szabo T; Godlewski K; Stahr L; Yussman Z; Palmer S; Vogel R
    Cathet Cardiovasc Diagn; 1992 May; 26(1):55-60. PubMed ID: 1499063
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Cardiac catheterization and coronary angiography using 5 French preformed (Judkins) catheters from the percutaneous right brachial approach: a comparative analysis with the femoral approach.
    Bush CA; VanFossen DB; Kolibash AJ; Magorien RD; Bacon JP; Ansel GM; Eaton GM; Ramancik MJ; Orsini AR; Palmer SL
    Cathet Cardiovasc Diagn; 1993 Aug; 29(4):267-72. PubMed ID: 8221844
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Use of 5 French catheters in percutaneous femoral coronaro-ventriculography (500 consecutive procedures with 5 French catheters)].
    Carosio G; Taverna G; Ballestrero G; Reale M; Massa R; Ravazzi PA
    G Ital Cardiol; 1991 Jul; 21(7):725-30. PubMed ID: 1765232
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Novel diagnostic catheter specifically designed for both coronary arteries via the right transradial approach. A prospective, randomized trial of Tiger II vs. Judkins catheters.
    Kim SM; Kim DK; Kim DI; Kim DS; Joo SJ; Lee JW
    Int J Cardiovasc Imaging; 2006; 22(3-4):295-303. PubMed ID: 16328852
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Perforation of a side branch of the right coronary artery during selective coronary angiography using 5 French Judkins catheters.
    Schöbel WA; Voelker W; Karsch KR
    Cathet Cardiovasc Diagn; 1995 Oct; 36(2):156-9. PubMed ID: 8829838
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [Coronarography using high-flow 5F catheters. Percutaneous technic using the femoral and brachial routes].
    Lupón Rosés J; Angel J; Domingo E; Anívarro I; Soler Soler J
    Rev Esp Cardiol; 1989 May; 42(5):299-303. PubMed ID: 2772365
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Randomized evaluation of 5 French catheters for coronary angiography with or without the CO2 powered Hercules syringe.
    Pande AK; Meier B; Villavicencio R; Urban P; de la Serna F
    J Invasive Cardiol; 1992 Apr; 4(3):136-8. PubMed ID: 10149894
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A randomised comparison of the use of 4 and 6 French diagnostic catheters: the limits of downsizing.
    Danzi GB; Capuano C; Sesana M; Di Blasi A; Predolini S; Laterza C; Quaini E
    Int J Cardiol; 2001 Jul; 79(2-3):113-7; discussion 117-8. PubMed ID: 11461729
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Evaluation of new 4 French catheters by comparison to 6 French coronary artery images.
    Saito T; Date H; Taniguchi I; Hokimoto S; Yamamoto N; Nakamura S; Ishibashi F; Noda K; Oshima S
    J Invasive Cardiol; 1999 Jan; 11(1):13-20. PubMed ID: 10745431
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A new lack of twist for the Judkins left coronary catheter.
    Hirshfeld JW; Untereker WJ; Goldberg S; Dienel NH; Drew T; Lozner E
    Cathet Cardiovasc Diagn; 1981; 7(3):331-5. PubMed ID: 7285110
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Coronary angiography using 4 French catheters with power injection: a randomized comparison with 6 French catheters.
    Arora P; Naik N; Bahl VK; Mishra S; Yadav R; Sharma S; Manchanda SC
    Indian Heart J; 2002; 54(2):184-8. PubMed ID: 12086383
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Comparison of 6 and 8 French catheters for arterial catheterization and coronarography: prospects of the development of coronarography in ambulatory care].
    Campolo L; Leonardi G; Millan G; Formentini A; Salvadè P; De Biase AM; Roghi A; Danzi G; Silva P
    G Ital Cardiol; 1990 Dec; 20(12):1118-24. PubMed ID: 2083807
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Percutaneous right brachial artery approach with 5F catheters for studying coronary artery disease.
    Lupon-Rosés J; Domingo E; Angel J; Anívarro I; Soler-Soler J
    Cathet Cardiovasc Diagn; 1991 Jan; 22(1):47-51. PubMed ID: 1995175
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Four French catheters for diagnostic coronary angiography.
    Mehta H; Chatterjee T; Windecker S; Eberli FR; Fleisch M; Seiler C; Hess OM; Meier B
    Catheter Cardiovasc Interv; 2003 Mar; 58(3):275-80. PubMed ID: 12594686
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Pediatric cardiac angiography using a 4 French catheter.
    Keane JF; Freed MD; Fellows KE; Fyler DC
    Cathet Cardiovasc Diagn; 1977; 3(3):313-9. PubMed ID: 912741
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Coronary angiography using 4 or 6 French diagnostic catheters: a prospective, randomized study.
    Lefevre T; Morice MC; Bonan R; Dumas P; Louvard Y; Karrillon G; Loubeyre C; Piechaud JF
    J Invasive Cardiol; 2001 Oct; 13(10):674-7. PubMed ID: 11581508
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Coronary angiography using 4-French preformed catheters--percutaneous brachial approach.
    Kitazume H; Kubo I; Ageishi Y; Iwama T
    Clin Cardiol; 1992 Nov; 15(11):826-32. PubMed ID: 10969626
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Decreasing length of stay in the hospital by coronary angiography with 5-French catheters].
    Erlemeier HH; Bleifeld W
    Z Kardiol; 1990 Sep; 79(9):641-6. PubMed ID: 2238775
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.