1098 related articles for article (PubMed ID: 22067188)
1. Usefulness of an intensive bowel cleansing strategy for repeat colonoscopy after preparation failure.
Ibáñez M; Parra-Blanco A; Zaballa P; Jiménez A; Fernández-Velázquez R; Fernández-Sordo JO; González-Bernardo O; Rodrigo L
Dis Colon Rectum; 2011 Dec; 54(12):1578-84. PubMed ID: 22067188
[TBL] [Abstract][Full Text] [Related]
2. Administration of olive oil followed by a low volume of polyethylene glycol-electrolyte lavage solution improves patient satisfaction with right-side colonic cleansing over administration of the conventional volume of polyethylene glycol-electrolyte lavage solution for colonoscopy preparation.
Abut E; Guveli H; Yasar B; Bolukbas C; Bolukbas FF; Ince AT; Kendir T; Dalay AR; Kurdas OO
Gastrointest Endosc; 2009 Sep; 70(3):515-21. PubMed ID: 19555936
[TBL] [Abstract][Full Text] [Related]
3. Comparison of Two Intensive Bowel Cleansing Regimens in Patients With Previous Poor Bowel Preparation: A Randomized Controlled Study.
Gimeno-García AZ; Hernandez G; Aldea A; Nicolás-Pérez D; Jiménez A; Carrillo M; Felipe V; Alarcón-Fernández O; Hernandez-Guerra M; Romero R; Alonso I; Gonzalez Y; Adrian Z; Moreno M; Ramos L; Quintero E
Am J Gastroenterol; 2017 Jun; 112(6):951-958. PubMed ID: 28291237
[TBL] [Abstract][Full Text] [Related]
4. Multicentre endoscopist-blinded randomised clinical trial to compare two bowel preparations after a colonoscopy with inadequate cleansing: a study protocol.
Sey MSL; von Renteln D; Sultanian R; McDonald C; Martel M; Barkun A
BMJ Open; 2019 Jul; 9(7):e029573. PubMed ID: 31289092
[TBL] [Abstract][Full Text] [Related]
5. Randomised clinical trial: low-volume bowel preparation for colonoscopy - a comparison between two different PEG-based formulations.
Repici A; Cestari R; Annese V; Biscaglia G; Vitetta E; Minelli L; Trallori G; Orselli S; Andriulli A; Hassan C
Aliment Pharmacol Ther; 2012 Oct; 36(8):717-24. PubMed ID: 22924336
[TBL] [Abstract][Full Text] [Related]
6. 2-Litre polyethylene glycol-citrate-simethicone plus bisacodyl versus 4-litre polyethylene glycol as preparation for colonoscopy in chronic constipation.
Parente F; Vailati C; Bargiggia S; Manes G; Fontana P; Masci E; Arena M; Spinzi G; Baccarin A; Mazzoleni G; Testoni PA
Dig Liver Dis; 2015 Oct; 47(10):857-63. PubMed ID: 26232311
[TBL] [Abstract][Full Text] [Related]
7. A dual-action, low-volume bowel cleanser administered the day before colonoscopy: results from the SEE CLEAR II study.
Katz PO; Rex DK; Epstein M; Grandhi NK; Vanner S; Hookey LC; Alderfer V; Joseph RE
Am J Gastroenterol; 2013 Mar; 108(3):401-9. PubMed ID: 23318484
[TBL] [Abstract][Full Text] [Related]
8. 2 L versus 4 L of PEG3350 + electrolytes for outpatient colonic preparation: a randomized, controlled trial.
Brahmania M; Ou G; Bressler B; Ko HK; Lam E; Telford J; Enns R
Gastrointest Endosc; 2014 Mar; 79(3):408-416.e4. PubMed ID: 24206747
[TBL] [Abstract][Full Text] [Related]
9. Same-day colonoscopy preparation with Senna alkaloids and bisacodyl tablets: a pilot study.
Yenidogan E; Okan I; Kayaoglu HA; Akgul GG; Sansal M; Tali S; Ozsoy Z; Sahin M
World J Gastroenterol; 2014 Nov; 20(41):15382-6. PubMed ID: 25386088
[TBL] [Abstract][Full Text] [Related]
10. Low-volume morning-only polyethylene glycol with specially designed test meals versus standard-volume split-dose polyethylene glycol with standard diet for colonoscopy: a prospective, randomized trial.
Seo EH; Kim TO; Park MJ; Heo NY; Park J; Yang SY
Digestion; 2013; 88(2):110-8. PubMed ID: 23949563
[TBL] [Abstract][Full Text] [Related]
11. Split dosing with a low-volume preparation is not inferior to split dosing with a high-volume preparation for bowel cleansing in patients with a history of colorectal resection: a randomized trial.
Mussetto A; Frazzoni L; Paggi S; Dari S; Laterza L; Radaelli F; Hassan C; Triossi O; Fuccio L
Endoscopy; 2015 Oct; 47(10):917-24. PubMed ID: 25910064
[TBL] [Abstract][Full Text] [Related]
12. A randomized, multicenter study comparing the safety and efficacy of sodium phosphate tablets with 2L polyethylene glycol solution plus bisacodyl tablets for colon cleansing.
Johanson JF; Popp JW; Cohen LB; Lottes SR; Forbes WP; Walker K; Carter E; Zhang B; Rose M
Am J Gastroenterol; 2007 Oct; 102(10):2238-46. PubMed ID: 17573796
[TBL] [Abstract][Full Text] [Related]
13. Comparison of asymmetric (low morning-dose) and standard split-dose regimen of PEG plus bisacodyl for bowel preparation: A randomized controlled trial.
Andreozzi P; De Nucci G; Bezzio C; Arena I; Devani M; Mandelli E; Morganti D; Omazzi B; Reati R; Redaelli D; Saibeni S; Manes G
Dig Liver Dis; 2019 Jun; 51(6):837-842. PubMed ID: 30658942
[TBL] [Abstract][Full Text] [Related]
14. Comparison of a split-dose bowel preparation with 2 liters of polyethylene glycol plus ascorbic acid and 1 liter of polyethylene glycol plus ascorbic acid and bisacodyl before colonoscopy.
Kang SH; Jeen YT; Lee JH; Yoo IK; Lee JM; Kim SH; Choi HS; Kim ES; Keum B; Lee HS; Chun HJ; Kim CD
Gastrointest Endosc; 2017 Aug; 86(2):343-348. PubMed ID: 27889546
[TBL] [Abstract][Full Text] [Related]
15. A new low-volume isosmotic polyethylene glycol solution plus bisacodyl versus split-dose 4 L polyethylene glycol for bowel cleansing prior to colonoscopy: a randomised controlled trial.
Cesaro P; Hassan C; Spada C; Petruzziello L; Vitale G; Costamagna G
Dig Liver Dis; 2013 Jan; 45(1):23-7. PubMed ID: 22917636
[TBL] [Abstract][Full Text] [Related]
16. Randomized controlled trial of sodium phosphate tablets vs polyethylene glycol solution for colonoscopy bowel cleansing.
Jung YS; Lee CK; Kim HJ; Eun CS; Han DS; Park DI
World J Gastroenterol; 2014 Nov; 20(42):15845-51. PubMed ID: 25400471
[TBL] [Abstract][Full Text] [Related]
17. Optimal preparation-to-colonoscopy interval in split-dose PEG bowel preparation determines satisfactory bowel preparation quality: an observational prospective study.
Seo EH; Kim TO; Park MJ; Joo HR; Heo NY; Park J; Park SH; Yang SY; Moon YS
Gastrointest Endosc; 2012 Mar; 75(3):583-90. PubMed ID: 22177570
[TBL] [Abstract][Full Text] [Related]
18. Polyethylene glycol versus sodium phosphate in bowel cleansing for colonoscopy: a randomized trial.
Huppertz-Hauss G; Bretthauer M; Sauar J; Paulsen J; Kjellevold Ø; Majak B; Hoff G
Endoscopy; 2005 Jun; 37(6):537-41. PubMed ID: 15933926
[TBL] [Abstract][Full Text] [Related]
19. One-day versus two-day cleansing for colon capsule endoscopy: a prospective randomized pilot study.
Ramos L; Alarcón O; Adrian Z; Gimeno-García AZ; Nicolás-Pérez D; Jiménez-Sosa A; Quintero E
Gastroenterol Hepatol; 2014 Mar; 37(3):101-6. PubMed ID: 24388792
[TBL] [Abstract][Full Text] [Related]
20. Clinical trial: sodium phosphate tablets are preferred and better tolerated by patients compared to polyethylene glycol solution plus bisacodyl tablets for bowel preparation.
Lichtenstein GR; Grandhi N; Schmalz M; Lottes SR; Forbes WP; Walker K; Zhang B
Aliment Pharmacol Ther; 2007 Nov; 26(10):1361-70. PubMed ID: 17983368
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]