These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

253 related articles for article (PubMed ID: 22071495)

  • 1. Quantitative force and dissipation measurements in liquids using piezo-excited atomic force microscopy: a unifying theory.
    Kiracofe D; Raman A
    Nanotechnology; 2011 Dec; 22(48):485502. PubMed ID: 22071495
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Dissipation and oscillatory solvation forces in confined liquids studied by small-amplitude atomic force spectroscopy.
    de Beer S; van den Ende D; Mugele F
    Nanotechnology; 2010 Aug; 21(32):325703. PubMed ID: 20639584
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Photothermal excitation and laser Doppler velocimetry of higher cantilever vibration modes for dynamic atomic force microscopy in liquid.
    Nishida S; Kobayashi D; Sakurada T; Nakazawa T; Hoshi Y; Kawakatsu H
    Rev Sci Instrum; 2008 Dec; 79(12):123703. PubMed ID: 19123565
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Modular apparatus for electrostatic actuation of common atomic force microscope cantilevers.
    Long CJ; Cannara RJ
    Rev Sci Instrum; 2015 Jul; 86(7):073703. PubMed ID: 26233392
    [TBL] [Abstract][Full Text] [Related]  

  • 5. High efficiency laser photothermal excitation of microcantilever vibrations in air and liquids.
    Kiracofe D; Kobayashi K; Labuda A; Raman A; Yamada H
    Rev Sci Instrum; 2011 Jan; 82(1):013702. PubMed ID: 21280832
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Energy dissipation and dynamic response of an amplitude-modulation atomic-force microscopy subjected to a tip-sample viscous force.
    Lin SM
    Ultramicroscopy; 2007; 107(2-3):245-53. PubMed ID: 16982149
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Atomic force microscopy in viscous ionic liquids.
    Labuda A; Grütter P
    Langmuir; 2012 Mar; 28(12):5319-22. PubMed ID: 22384786
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Characterization of surface stiffness and probe-sample dissipation using the band excitation method of atomic force microscopy: a numerical analysis.
    Kareem AU; Solares SD
    Nanotechnology; 2012 Jan; 23(1):015706. PubMed ID: 22155951
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Atomic force microscopy of confined liquids using the thermal bending fluctuations of the cantilever.
    Liu F; de Beer S; van den Ende D; Mugele F
    Phys Rev E Stat Nonlin Soft Matter Phys; 2013 Jun; 87(6):062406. PubMed ID: 23848696
    [TBL] [Abstract][Full Text] [Related]  

  • 10. High-resolution noncontact atomic force microscopy.
    Pérez R; García R; Schwarz U
    Nanotechnology; 2009 Jul; 20(26):260201. PubMed ID: 19531843
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Amplitude modulation atomic force microscopy, is acoustic driving in liquid quantitatively reliable?
    Liu F; Zhao C; Mugele F; van den Ende D
    Nanotechnology; 2015 Sep; 26(38):385703. PubMed ID: 26335613
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Atomic-resolution imaging in liquid by frequency modulation atomic force microscopy using small cantilevers with megahertz-order resonance frequencies.
    Fukuma T; Onishi K; Kobayashi N; Matsuki A; Asakawa H
    Nanotechnology; 2012 Apr; 23(13):135706. PubMed ID: 22421199
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Bimodal atomic force microscopy imaging of isolated antibodies in air and liquids.
    Martínez NF; Lozano JR; Herruzo ET; Garcia F; Richter C; Sulzbach T; Garcia R
    Nanotechnology; 2008 Sep; 19(38):384011. PubMed ID: 21832570
    [TBL] [Abstract][Full Text] [Related]  

  • 14. High viscosity environments: an unexpected route to obtain true atomic resolution with atomic force microscopy.
    Weber SA; Kilpatrick JI; Brosnan TM; Jarvis SP; Rodriguez BJ
    Nanotechnology; 2014 May; 25(17):175701. PubMed ID: 24717916
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Temperature dependence of solvation forces as measured in atomic force microscopy.
    Lim LT; Wee AT; O'Shea SJ
    J Chem Phys; 2009 Apr; 130(13):134703. PubMed ID: 19355760
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Nanorheology by atomic force microscopy.
    Li TD; Chiu HC; Ortiz-Young D; Riedo E
    Rev Sci Instrum; 2014 Dec; 85(12):123707. PubMed ID: 25554301
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Effect of tip size on force measurement in atomic force microscopy.
    Lim LT; Wee AT; O'Shea SJ
    Langmuir; 2008 Mar; 24(6):2271-3. PubMed ID: 18266396
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Dual resonance excitation system for the contact mode of atomic force microscopy.
    Kopycinska-Müller M; Striegler A; Schlegel R; Kuzeyeva N; Köhler B; Wolter KJ
    Rev Sci Instrum; 2012 Apr; 83(4):043703. PubMed ID: 22559535
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Contact resonance atomic force microscopy imaging in air and water using photothermal excitation.
    Kocun M; Labuda A; Gannepalli A; Proksch R
    Rev Sci Instrum; 2015 Aug; 86(8):083706. PubMed ID: 26329202
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Theory of non-equilibrium force measurements involving deformable drops and bubbles.
    Chan DY; Klaseboer E; Manica R
    Adv Colloid Interface Sci; 2011 Jul; 165(2):70-90. PubMed ID: 21257141
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 13.