These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

96 related articles for article (PubMed ID: 2207231)

  • 21. Carbon dioxide and oxygen partial pressure measurements in the cerebrospinal fluid in a conventional blood gas analyzer: analysis of bias and precision.
    Venkatesh B; Boots RJ
    J Neurol Sci; 1997 Mar; 147(1):5-8. PubMed ID: 9094053
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Micro-pressure sensor for continuous monitoring of a ventricular assist device.
    Nitta S; Katahira Y; Yambe T; Sonobe T; Hayashi H; Tanaka M; Sato N; Miura M; Mohri H; Esashi M
    Int J Artif Organs; 1990 Dec; 13(12):823-9. PubMed ID: 2289835
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Oxygen sensitivity of a multichannel antimony microelectrode for tissue surface oxygen pressure measurements.
    Sjöberg F; Thorborg P; Wranne B; Lund N
    Microcirc Endothelium Lymphatics; 1990; 6(2-3):127-48. PubMed ID: 2247022
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Practical experiences with the routine application of the intravascular PO2 probe.
    Büttner W
    Biotelem Patient Monit; 1979; 6(1-2):44-50. PubMed ID: 486724
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Anticoagulation and endothelial cell behaviors of heparin-loaded graphene oxide coating on titanium surface.
    Pan CJ; Pang LQ; Gao F; Wang YN; Liu T; Ye W; Hou YH
    Mater Sci Eng C Mater Biol Appl; 2016 Jun; 63():333-40. PubMed ID: 27040227
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Development of fiber optic fluorescence oxygen sensor in both in vitro and in vivo systems.
    Jiang J; Gao L; Zhong W; Meng S; Yong B; Song Y; Wang X; Bai C
    Respir Physiol Neurobiol; 2008 Apr; 161(2):160-6. PubMed ID: 18378503
    [TBL] [Abstract][Full Text] [Related]  

  • 27. [Transcutaneous measurement of pO2.(author's transl)].
    Dautzenberg B; Carter H; Sors C
    Rev Fr Mal Respir; 1981; 9(4):327-35. PubMed ID: 7302351
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Problems of continuous Pa, O2 monitoring by means of indwelling intra-arterial electrodes.
    Goeckenjan G; Dure H
    Resuscitation; 1978; 6(3):207-14. PubMed ID: 741098
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Continuous intra-arterial blood gas and pH monitoring in critically ill patients with severe respiratory failure: a prospective, criterion standard study.
    Haller M; Kilger E; Briegel J; Forst H; Peter K
    Crit Care Med; 1994 Apr; 22(4):580-7. PubMed ID: 8143467
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Tissue oxygen tension in rabbits measured with a galvanic electrode.
    Towell ME; Lysak I; Layne EC; Bessman SP
    J Appl Physiol; 1976 Aug; 41(2):245-50. PubMed ID: 956108
    [TBL] [Abstract][Full Text] [Related]  

  • 31. An intravascular oxygen tension monitoring device used in myocutaneous transplants: a preliminary report.
    Hofer SO; Timmenga EJ; Christiano R; Bos KE
    Microsurgery; 1993; 14(5):304-9; discussion 310-1. PubMed ID: 8332049
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Multisite evaluation of a continuous intraarterial blood gas monitoring system.
    Larson CP; Vender J; Seiver A
    Anesthesiology; 1994 Sep; 81(3):543-52. PubMed ID: 8092498
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Glucose biosensors with enzyme entrapped in polymer coating.
    Yang S; Atanasov P; Wilkins E
    Biomed Instrum Technol; 1995; 29(2):125-33. PubMed ID: 7773322
    [TBL] [Abstract][Full Text] [Related]  

  • 34. In vivo assessment of catheter-tip PO2 sensor: sampling lumen fabrication.
    Spencer A; Rolfe P; Murphy A; Wright T; McKenna S
    Med Biol Eng Comput; 1995 Mar; 33(2):157-62. PubMed ID: 7643653
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Monitoring of blood oxygen tension during and after anesthesia with a bed-side PO2 meter.
    Dercksen SJ; Linssen GH
    Acta Anaesthesiol Belg; 1977 Mar; 28(1):33-9. PubMed ID: 920107
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Continuous measurement of scalp tissue oxygen tension and carotid arterial oxygen tension in the fetal lamb.
    Aarnoudse JG; Oeseburg B; Kwant G; Huisjes HJ; Zijlstra WG
    Biol Neonate; 1980; 38(1-2):49-60. PubMed ID: 7388089
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Continuous Fetal Scalp and Carotid Artery Oxygen Tension Monitoring in the Sheep.
    Staisch K; Nuwayhid B; Bauer R; Welsh L; Brinkman CR
    Obstet Gynecol; 1976 May; 47(5):587-92. PubMed ID: 1264404
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Poly(dimethylsiloxane)-poly(ethylene oxide)-heparin block copolymers. II: Surface characterization and in vitro assessments.
    Grainger DW; Knutson K; Kim SW; Feijen J
    J Biomed Mater Res; 1990 Apr; 24(4):403-31. PubMed ID: 2347871
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Skin sensors for continuous oxygen monitoring of newborns.
    Eberhard P; Mindt W
    Biotelemetry; 1977; 4(2):48-76. PubMed ID: 610772
    [TBL] [Abstract][Full Text] [Related]  

  • 40. New surface biopolymers for oxygenators: an in vitro hemocompatibility test of poly(2-methoxyethylacrylate).
    Baykut D; Bernet F; Wehrle J; Weichelt K; Schwartz P; Zerkowski HR
    Eur J Med Res; 2001 Jul; 6(7):297-305. PubMed ID: 11485890
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 5.