These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
119 related articles for article (PubMed ID: 22074029)
1. The effect of sterilisation on the plasticity of multi-use Eschmann gum elastic bougies: a bench and manikin study. Dawes TJ; Ford PN Anaesthesia; 2011 Dec; 66(12):1134-9. PubMed ID: 22074029 [TBL] [Abstract][Full Text] [Related]
2. The effect of temperature on bougies: a photographic and manikin study. Mingo O; Suaris P; Charman S; Ferguson C; Patel A Anaesthesia; 2008 Oct; 63(10):1135-8. PubMed ID: 18717662 [TBL] [Abstract][Full Text] [Related]
3. Bougies as an aid for endotracheal intubation with the Airway Scope: bench and manikin comparison studies. Takenaka I; Aoyama K; Iwagaki T; Takenaka Y BMC Anesthesiol; 2017 Oct; 17(1):133. PubMed ID: 28969598 [TBL] [Abstract][Full Text] [Related]
4. Comparison of the Airway Scope, gum elastic bougie and fibreoptic bronchoscope in simulated difficult tracheal intubation: a manikin study. Koyama Y; Inagawa G; Miyashita T; Kikuchi T; Miura N; Miki T; Kurihara R; Kamiya Y; Goto T Anaesthesia; 2007 Sep; 62(9):936-9. PubMed ID: 17697222 [TBL] [Abstract][Full Text] [Related]
5. Comparison of malleable stylet and reusable and disposable bougies by paramedics in a simulated difficult intubation. Gregory P; Woollard M; Lighton D; Munro G; Jenkinson E; Newcombe RG; O'Meara P; Hamilton L Anaesthesia; 2012 Apr; 67(4):371-6. PubMed ID: 22288931 [TBL] [Abstract][Full Text] [Related]
6. A comparison of the Seeing Optical Stylet and the gum elastic bougie in simulated difficult tracheal intubation: a manikin study. Evans A; Morris S; Petterson J; Hall JE Anaesthesia; 2006 May; 61(5):478-81. PubMed ID: 16674624 [TBL] [Abstract][Full Text] [Related]
7. Comparison of a disposable bougie versus a newly designed malleable bougie in the intubation of a difficult manikin airway. Boedeker BH; Bernhagen M; Miller DJ; Murray WB Stud Health Technol Inform; 2011; 163():65-7. PubMed ID: 21335760 [TBL] [Abstract][Full Text] [Related]
8. Evaluation of Frova, single-use intubation introducer, in a manikin. Comparison with Eschmann multiple-use introducer and Portex single-use introducer. Hodzovic I; Latto IP; Wilkes AR; Hall JE; Mapleson WW Anaesthesia; 2004 Aug; 59(8):811-6. PubMed ID: 15270974 [TBL] [Abstract][Full Text] [Related]
9. A comparison of a fiberoptic stylet and a bougie as adjuncts to direct laryngoscopy in a manikin-simulated difficult airway. Kovacs G; Law JA; McCrossin C; Vu M; Leblanc D; Gao J Ann Emerg Med; 2007 Dec; 50(6):676-85. PubMed ID: 17681639 [TBL] [Abstract][Full Text] [Related]
10. To shape or not to shape...simulated bougie-assisted difficult intubation in a manikin. Hodzovic I; Wilkes AR; Latto IP Anaesthesia; 2003 Aug; 58(8):792-7. PubMed ID: 12859474 [TBL] [Abstract][Full Text] [Related]
11. Comparison of available gum-elastic bougies. Braude D; Ronan D; Weiss S; Boivin M; Gerstein N Am J Emerg Med; 2009 Mar; 27(3):266-70. PubMed ID: 19328368 [TBL] [Abstract][Full Text] [Related]
12. A comparison of simulated difficult intubation with multiple-use and single-use bougies in a manikin. Annamaneni R; Hodzovic I; Wilkes AR; Latto IP Anaesthesia; 2003 Jan; 58(1):45-9. PubMed ID: 12492669 [TBL] [Abstract][Full Text] [Related]
14. Bougie-related airway trauma: dangers of the hold-up sign. Marson BA; Anderson E; Wilkes AR; Hodzovic I Anaesthesia; 2014 Mar; 69(3):219-23. PubMed ID: 24548354 [TBL] [Abstract][Full Text] [Related]
15. Bougie-assisted difficult airway management in a manikin - the effect of position held on placement and force exerted by the tip. Hodzovic I; Wilkes AR; Latto IP Anaesthesia; 2004 Jan; 59(1):38-43. PubMed ID: 14687097 [TBL] [Abstract][Full Text] [Related]
16. Evaluation of the new Viewmax laryngoscope in a simulated difficult airway. Leung YY; Hung CT; Tan ST Acta Anaesthesiol Scand; 2006 May; 50(5):562-7. PubMed ID: 16643225 [TBL] [Abstract][Full Text] [Related]
17. Effect of cardiopulmonary resuscitation on intubation using a Macintosh laryngoscope, the AirWay Scope, and the gum elastic bougie: A manikin study. Maruyama K; Tsukamoto S; Ohno S; Kobayashi K; Nakagawa H; Kitamura A; Hayashida M Resuscitation; 2010 Aug; 81(8):1014-8. PubMed ID: 20605669 [TBL] [Abstract][Full Text] [Related]
18. A comparison of the I-gel supraglottic airway as a conduit for tracheal intubation with the intubating laryngeal mask airway: a manikin study. Michalek P; Donaldson W; Graham C; Hinds JD Resuscitation; 2010 Jan; 81(1):74-7. PubMed ID: 19926388 [TBL] [Abstract][Full Text] [Related]
19. Forces required to remove bougies from tracheal tubes. Jackson GN; Bartlett R; Yentis SM Anaesthesia; 2009 Mar; 64(3):320-2. PubMed ID: 19302648 [TBL] [Abstract][Full Text] [Related]
20. [Comparative evaluation of single-use gum-elastic bougie in a manikin-simulator (SimMAN)]. Gibert F; Lenfant F; Avena C; Albertini S; Cailliod R; Freysz M Ann Fr Anesth Reanim; 2009 Mar; 28(3):255-6. PubMed ID: 19299101 [No Abstract] [Full Text] [Related] [Next] [New Search]