BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

124 related articles for article (PubMed ID: 22074029)

  • 1. The effect of sterilisation on the plasticity of multi-use Eschmann gum elastic bougies: a bench and manikin study.
    Dawes TJ; Ford PN
    Anaesthesia; 2011 Dec; 66(12):1134-9. PubMed ID: 22074029
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The effect of temperature on bougies: a photographic and manikin study.
    Mingo O; Suaris P; Charman S; Ferguson C; Patel A
    Anaesthesia; 2008 Oct; 63(10):1135-8. PubMed ID: 18717662
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Bougies as an aid for endotracheal intubation with the Airway Scope: bench and manikin comparison studies.
    Takenaka I; Aoyama K; Iwagaki T; Takenaka Y
    BMC Anesthesiol; 2017 Oct; 17(1):133. PubMed ID: 28969598
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Comparison of the Airway Scope, gum elastic bougie and fibreoptic bronchoscope in simulated difficult tracheal intubation: a manikin study.
    Koyama Y; Inagawa G; Miyashita T; Kikuchi T; Miura N; Miki T; Kurihara R; Kamiya Y; Goto T
    Anaesthesia; 2007 Sep; 62(9):936-9. PubMed ID: 17697222
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Comparison of malleable stylet and reusable and disposable bougies by paramedics in a simulated difficult intubation.
    Gregory P; Woollard M; Lighton D; Munro G; Jenkinson E; Newcombe RG; O'Meara P; Hamilton L
    Anaesthesia; 2012 Apr; 67(4):371-6. PubMed ID: 22288931
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A comparison of the Seeing Optical Stylet and the gum elastic bougie in simulated difficult tracheal intubation: a manikin study.
    Evans A; Morris S; Petterson J; Hall JE
    Anaesthesia; 2006 May; 61(5):478-81. PubMed ID: 16674624
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Comparison of a disposable bougie versus a newly designed malleable bougie in the intubation of a difficult manikin airway.
    Boedeker BH; Bernhagen M; Miller DJ; Murray WB
    Stud Health Technol Inform; 2011; 163():65-7. PubMed ID: 21335760
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Evaluation of Frova, single-use intubation introducer, in a manikin. Comparison with Eschmann multiple-use introducer and Portex single-use introducer.
    Hodzovic I; Latto IP; Wilkes AR; Hall JE; Mapleson WW
    Anaesthesia; 2004 Aug; 59(8):811-6. PubMed ID: 15270974
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A comparison of a fiberoptic stylet and a bougie as adjuncts to direct laryngoscopy in a manikin-simulated difficult airway.
    Kovacs G; Law JA; McCrossin C; Vu M; Leblanc D; Gao J
    Ann Emerg Med; 2007 Dec; 50(6):676-85. PubMed ID: 17681639
    [TBL] [Abstract][Full Text] [Related]  

  • 10. To shape or not to shape...simulated bougie-assisted difficult intubation in a manikin.
    Hodzovic I; Wilkes AR; Latto IP
    Anaesthesia; 2003 Aug; 58(8):792-7. PubMed ID: 12859474
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Comparison of available gum-elastic bougies.
    Braude D; Ronan D; Weiss S; Boivin M; Gerstein N
    Am J Emerg Med; 2009 Mar; 27(3):266-70. PubMed ID: 19328368
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A comparison of simulated difficult intubation with multiple-use and single-use bougies in a manikin.
    Annamaneni R; Hodzovic I; Wilkes AR; Latto IP
    Anaesthesia; 2003 Jan; 58(1):45-9. PubMed ID: 12492669
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Evaluation of tracheal tube introducers in simulated difficult intubation.
    Janakiraman C; Hodzovic I; Reddy S; Desai N; Wilkes AR; Latto IP
    Anaesthesia; 2009 Mar; 64(3):309-14. PubMed ID: 19302646
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Bougie-related airway trauma: dangers of the hold-up sign.
    Marson BA; Anderson E; Wilkes AR; Hodzovic I
    Anaesthesia; 2014 Mar; 69(3):219-23. PubMed ID: 24548354
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Bougie-assisted difficult airway management in a manikin - the effect of position held on placement and force exerted by the tip.
    Hodzovic I; Wilkes AR; Latto IP
    Anaesthesia; 2004 Jan; 59(1):38-43. PubMed ID: 14687097
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Evaluation of the new Viewmax laryngoscope in a simulated difficult airway.
    Leung YY; Hung CT; Tan ST
    Acta Anaesthesiol Scand; 2006 May; 50(5):562-7. PubMed ID: 16643225
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Effect of cardiopulmonary resuscitation on intubation using a Macintosh laryngoscope, the AirWay Scope, and the gum elastic bougie: A manikin study.
    Maruyama K; Tsukamoto S; Ohno S; Kobayashi K; Nakagawa H; Kitamura A; Hayashida M
    Resuscitation; 2010 Aug; 81(8):1014-8. PubMed ID: 20605669
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A comparison of the I-gel supraglottic airway as a conduit for tracheal intubation with the intubating laryngeal mask airway: a manikin study.
    Michalek P; Donaldson W; Graham C; Hinds JD
    Resuscitation; 2010 Jan; 81(1):74-7. PubMed ID: 19926388
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Forces required to remove bougies from tracheal tubes.
    Jackson GN; Bartlett R; Yentis SM
    Anaesthesia; 2009 Mar; 64(3):320-2. PubMed ID: 19302648
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Comparative evaluation of single-use gum-elastic bougie in a manikin-simulator (SimMAN)].
    Gibert F; Lenfant F; Avena C; Albertini S; Cailliod R; Freysz M
    Ann Fr Anesth Reanim; 2009 Mar; 28(3):255-6. PubMed ID: 19299101
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 7.