These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

65 related articles for article (PubMed ID: 22075052)

  • 21. Field trial and modeling of uptake rates of in situ lipid-free polyethylene membrane passive sampler.
    Anderson KA; Sethajintanin D; Sower G; Quarles L
    Environ Sci Technol; 2008 Jun; 42(12):4486-93. PubMed ID: 18605575
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Controlling and maintaining exposure of hydrophobic organic compounds in aquatic toxicity tests by passive dosing.
    Smith KE; Dom N; Blust R; Mayer P
    Aquat Toxicol; 2010 Jun; 98(1):15-24. PubMed ID: 20170970
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Equilibrium sampling: partitioning of organochlorine compounds from lipids into polydimethylsiloxane.
    Jahnke A; McLachlan MS; Mayer P
    Chemosphere; 2008 Nov; 73(10):1575-81. PubMed ID: 18926556
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Effect of housing geometry on the performance of Chemcatcher passive sampler for the monitoring of hydrophobic organic pollutants in water.
    Lobpreis T; Vrana B; Dominiak E; Dercová K; Mills GA; Greenwood R
    Environ Pollut; 2008 Jun; 153(3):706-10. PubMed ID: 17964701
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Calibration and field application of a solvent-based cellulose membrane passive sampling device for the monitoring of polar herbicides.
    Hyne RV; Aistrope M
    Chemosphere; 2008 Mar; 71(4):611-20. PubMed ID: 18160095
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Measuring nonpolar organic contaminant partitioning in three Norwegian sediments using polyethylene passive samplers.
    Allan IJ; Ruus A; Schaanning MT; Macrae KJ; Næs K
    Sci Total Environ; 2012 Apr; 423():125-31. PubMed ID: 22421090
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Simultaneous determination of pesticides, polycyclic aromatic hydrocarbons and polychlorinated biphenyls in seawater and interstitial marine water samples, using stir bar sorptive extraction-thermal desorption-gas chromatography-mass spectrometry.
    Pérez-Carrera E; León VM; Parra AG; González-Mazo E
    J Chromatogr A; 2007 Nov; 1170(1-2):82-90. PubMed ID: 17915232
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Membrane assisted passive sampler for triazine compounds in water bodies--characterization of environmental conditions and field performance.
    Nyoni H; Chimuka L; Vrana B; Cukrowska E
    Anal Chim Acta; 2011 May; 694(1-2):75-82. PubMed ID: 21565305
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Sorptive extraction using polydimethylsiloxane/metal-organic framework coated stir bars coupled with high performance liquid chromatography-fluorescence detection for the determination of polycyclic aromatic hydrocarbons in environmental water samples.
    Hu C; He M; Chen B; Zhong C; Hu B
    J Chromatogr A; 2014 Aug; 1356():45-53. PubMed ID: 25001335
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Partitioning and accumulation rates of polycyclic aromatic hydrocarbons into polydimethylsiloxane thin films and black worms from aqueous samples.
    Qin Z; Mok S; Ouyang G; Dixon DG; Pawliszyn J
    Anal Chim Acta; 2010 May; 667(1-2):71-6. PubMed ID: 20441868
    [TBL] [Abstract][Full Text] [Related]  

  • 31. PAH toxicity at aqueous solubility in the fish embryo test with Danio rerio using passive dosing.
    Seiler TB; Best N; Fernqvist MM; Hercht H; Smith KE; Braunbeck T; Mayer P; Hollert H
    Chemosphere; 2014 Oct; 112():77-84. PubMed ID: 25048891
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Field performance of the Chemcatcher passive sampler for monitoring hydrophobic organic pollutants in surface water.
    Vrana B; Mills GA; Leonards PE; Kotterman M; Weideborg M; Hajslová J; Kocourek V; Tomaniová M; Pulkrabová J; Suchanová M; Hájková K; Herve S; Ahkola H; Greenwood R
    J Environ Monit; 2010 Apr; 12(4):863-72. PubMed ID: 20383367
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Equilibrium partition coefficients of diverse polar and nonpolar organic compounds to polyoxymethylene (POM) passive sampling devices.
    Endo S; Hale SE; Goss KU; Arp HP
    Environ Sci Technol; 2011 Dec; 45(23):10124-32. PubMed ID: 22003872
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Passive air sampling theory for semivolatile organic compounds.
    Bartkow ME; Booij K; Kennedy KE; Müller JF; Hawker DW
    Chemosphere; 2005 Jul; 60(2):170-6. PubMed ID: 15914236
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Effect of condensed organic matter on solvent extraction and aqueous leaching of polycyclic aromatic hydrocarbons in soils and sediments.
    Ran Y; Sun K; Ma X; Wang G; Grathwohl P; Zeng EY
    Environ Pollut; 2007 Jul; 148(2):529-38. PubMed ID: 17257721
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Polydimethylsiloxane/metal-organic frameworks coated stir bar sorptive extraction coupled to high performance liquid chromatography-ultraviolet detector for the determination of estrogens in environmental water samples.
    Hu C; He M; Chen B; Zhong C; Hu B
    J Chromatogr A; 2013 Oct; 1310():21-30. PubMed ID: 23992883
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Stable nonpolar solvent droplet generation using a poly(dimethylsiloxane) microfluidic channel coated with poly-p-xylylene for a nanoparticle growth.
    Lim H; Moon S
    Biomed Microdevices; 2015 Aug; 17(4):70. PubMed ID: 26112614
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Polydimethylsiloxane-based permeation passive air sampler. Part I: Calibration constants and their relation to retention indices of the analytes.
    Seethapathy S; Górecki T
    J Chromatogr A; 2011 Jan; 1218(1):143-55. PubMed ID: 21112594
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Development of the performance reference compound approach for the calibration of "polar organic chemical integrative sampler" (POCIS).
    Belles A; Tapie N; Pardon P; Budzinski H
    Anal Bioanal Chem; 2014 Feb; 406(4):1131-40. PubMed ID: 23978936
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Possibilities and limitations of equilibrium sampling using polydimethylsiloxane in fish tissue.
    Jahnke A; Mayer P; Broman D; McLachlan MS
    Chemosphere; 2009 Oct; 77(6):764-70. PubMed ID: 19765800
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 4.