These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

115 related articles for article (PubMed ID: 22075124)

  • 1. The Pentax-AWS video laryngoscope for emergency airway management.
    Corso RM; Piraccini E; Terzitta M; Vargas JL; Gaetani S; Rotondo C; Agnoletti V; Gambale G
    Am J Emerg Med; 2011 Nov; 29(9):1227-8. PubMed ID: 22075124
    [No Abstract]   [Full Text] [Related]  

  • 2. Utility of the Pentax-AWS without interruption of chest compression: comparison of the Macintosh laryngoscope with the Pentax-AWS in manikin model.
    Han SK; Shin DH; Choi PC
    Resuscitation; 2010 Jan; 81(1):69-73. PubMed ID: 19919888
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The Pentax-AWS((R)) rigid indirect video laryngoscope: clinical assessment of performance in 320 cases.
    Suzuki A; Toyama Y; Katsumi N; Kunisawa T; Sasaki R; Hirota K; Henderson JJ; Iwasaki H
    Anaesthesia; 2008 Jun; 63(6):641-7. PubMed ID: 18477277
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Tracheal intubation by non-anesthesia residents using the Pentax-AWS airway scope and Macintosh laryngoscope.
    Hirabayashi Y; Seo N
    J Clin Anesth; 2009 Jun; 21(4):268-71. PubMed ID: 19502032
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Video RIFL: a rigid flexible laryngoscope to facilitate airway management.
    Setty H; Rawlings JL; Dubin S
    J Clin Anesth; 2010 Dec; 22(8):642-7. PubMed ID: 21109141
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Comparison of the Pentax-AWS and Fineview video laryngoscopes in the ease of laryngoscopy in 50 patients].
    Enomoto Y; Shimizu K; Hashimoto Y; Kamishima K; Arai T; Inoue H; Asai T; Okuda Y
    Masui; 2008 Dec; 57(12):1498-501. PubMed ID: 19108493
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Simulation based training of airway management with Macintosh blade and Glidescope video laryngoscope.
    Latif RK; Akca O
    Minerva Anestesiol; 2011 Jan; 77(1):1-3. PubMed ID: 21273961
    [No Abstract]   [Full Text] [Related]  

  • 8. Tracheal intubation with the PENTAX-AWS (airway scope) reduces changes of hemodynamic responses and bispectral index scores compared with the Macintosh laryngoscope.
    Nishikawa K; Matsuoka H; Saito S
    J Neurosurg Anesthesiol; 2009 Oct; 21(4):292-6. PubMed ID: 19955890
    [TBL] [Abstract][Full Text] [Related]  

  • 9. The Pentax-AWS video-laryngoscope: the first experience in one hundred patients.
    Asai T; Enomoto Y; Shimizu K; Shingu K; Okuda Y
    Anesth Analg; 2008 Jan; 106(1):257-9, table of contents. PubMed ID: 18165587
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Tracheal intubation during chest compressions using Pentax-AWS(®), GlideScope (®), and Macintosh laryngoscope: a randomized crossover trial using a mannequin.
    Shin DH; Choi PC; Han SK
    Can J Anaesth; 2011 Aug; 58(8):733-9. PubMed ID: 21630116
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Airway Scope for emergency intubations: usefulness of a new video-laryngoscope.
    Sadamori T; Kusunoki S; Otani T; Ishida M; Masuda R; Tamura T; Takeda T; Tsumura R; Shokawa T; Kondo T; Sakai H; Iwasaki Y; Yamanoue T; Hirohashi N; Tanigawa K
    Hiroshima J Med Sci; 2008 Dec; 57(3-4):99-104. PubMed ID: 19260562
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Use of the Pentax-AWS videolaryngoscope for bougie-assisted exchange of tracheal tubes].
    Kishii M; Asai T; Nagata A; Shingu K
    Masui; 2009 Jun; 58(6):765-7. PubMed ID: 19522274
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Use of a gum elastic bougie for tracheal intubation with Pentax-AWS airway scope].
    Ueshima H; Asai T; Shingu K; Inoue H; Hashimoto Y; Enomoto Y; Okuda Y
    Masui; 2008 Jan; 57(1):82-4. PubMed ID: 18214009
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Difficult airway management using the Pentax-AWS Airwayscope with a thin Intlock and bronchofiberscope in a patient with Coffin-Lowry syndrome.
    Deguchi S; Komasawa N; Morimoto K; Minami T
    J Clin Anesth; 2016 Mar; 29():1-2. PubMed ID: 26897436
    [No Abstract]   [Full Text] [Related]  

  • 15. [Pentax-AWS improves laryngeal view compared with Macintosh blade during laryngoscopy and facilitates easier intubation].
    Suzuki A; Toyama Y; Katsumi N; Sasaki R; Hirota K; Matsumoto H; Takahata O; Iwasaki H
    Masui; 2007 Apr; 56(4):464-8. PubMed ID: 17441461
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Successful airway management in patient with Goldenhar's syndrome using Truview PCD ® laryngoscope.
    Al-Abri AS; Khan RM; Haris A; Kaul N
    Paediatr Anaesth; 2012 Dec; 22(12):1229-31. PubMed ID: 23134168
    [No Abstract]   [Full Text] [Related]  

  • 17. [Pediatric difficult airway management].
    Suzuki Y
    Masui; 2011 Nov; 60 Suppl():S121-32. PubMed ID: 22458030
    [No Abstract]   [Full Text] [Related]  

  • 18. The difficult pediatric airway--a review of new devices for indirect laryngoscopy in children younger than two years of age.
    Holm-Knudsen R
    Paediatr Anaesth; 2011 Feb; 21(2):98-103. PubMed ID: 21159025
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Modification of endotracheal intubation using AirwayScope™ videolaryngoscope for straight reinforced tubes.
    Minonishi T; Kinoshita H; Hirayama M; Hatakeyama N; Matsuda N
    Minerva Anestesiol; 2011 Aug; 77(8):850-1. PubMed ID: 21730933
    [No Abstract]   [Full Text] [Related]  

  • 20. Comparison of the Pentax AWS videolaryngoscope with the Macintosh laryngoscope in simulated difficult airway intubations by emergency physicians.
    Phillips S; Celenza A
    Am J Emerg Med; 2011 Oct; 29(8):863-7. PubMed ID: 20825915
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.