These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
521 related articles for article (PubMed ID: 22078422)
1. Multimodality imaging in transcatheter aortic valve implantation and post-procedural aortic regurgitation: comparison among cardiovascular magnetic resonance, cardiac computed tomography, and echocardiography. Jabbour A; Ismail TF; Moat N; Gulati A; Roussin I; Alpendurada F; Park B; Okoroafor F; Asgar A; Barker S; Davies S; Prasad SK; Rubens M; Mohiaddin RH J Am Coll Cardiol; 2011 Nov; 58(21):2165-73. PubMed ID: 22078422 [TBL] [Abstract][Full Text] [Related]
2. Comparison of two- and three-dimensional transthoracic echocardiography to cardiac magnetic resonance imaging for assessment of paravalvular regurgitation after transcatheter aortic valve implantation. Altiok E; Frick M; Meyer CG; Al Ateah G; Napp A; Kirschfink A; Almalla M; Lotfi S; Becker M; Herich L; Lehmacher W; Hoffmann R Am J Cardiol; 2014 Jun; 113(11):1859-66. PubMed ID: 24837265 [TBL] [Abstract][Full Text] [Related]
3. Cardiac magnetic resonance versus transthoracic echocardiography for the assessment and quantification of aortic regurgitation in patients undergoing transcatheter aortic valve implantation. Ribeiro HB; Le Ven F; Larose E; Dahou A; Nombela-Franco L; Urena M; Allende R; Amat-Santos I; Ricapito Mde L; Thébault C; Clavel MA; Delarochelliére R; Doyle D; Dumont E; Dumesnil JG; Pibarot P; Rodés-Cabau J Heart; 2014 Dec; 100(24):1924-32. PubMed ID: 25124218 [TBL] [Abstract][Full Text] [Related]
4. Value of CMR in quantification of paravalvular aortic regurgitation after TAVI. Salaun E; Jacquier A; Theron A; Giorgi R; Lambert M; Jaussaud N; Hubert S; Collart F; Bonnet JL; Habib G; Cuisset T; Grisoli D Eur Heart J Cardiovasc Imaging; 2016 Jan; 17(1):41-50. PubMed ID: 26188194 [TBL] [Abstract][Full Text] [Related]
5. Meta-Analysis of Transthoracic Echocardiography Versus Cardiac Magnetic Resonance for the Assessment of Aortic Regurgitation After Transcatheter Aortic Valve Implantation. Papanastasiou CA; Kokkinidis DG; Jonnalagadda AK; Oikonomou EK; Kampaktsis PN; Garcia MJ; Myerson SG; Karamitsos TD Am J Cardiol; 2019 Oct; 124(8):1246-1251. PubMed ID: 31466694 [TBL] [Abstract][Full Text] [Related]
6. Prospective comparison of valve regurgitation quantitation by cardiac magnetic resonance imaging and transthoracic echocardiography. Cawley PJ; Hamilton-Craig C; Owens DS; Krieger EV; Strugnell WE; Mitsumori L; D'Jang CL; Schwaegler RG; Nguyen KQ; Nguyen B; Maki JH; Otto CM Circ Cardiovasc Imaging; 2013 Jan; 6(1):48-57. PubMed ID: 23212272 [TBL] [Abstract][Full Text] [Related]
7. Aortic regurgitation severity after transcatheter aortic valve implantation is underestimated by echocardiography compared with MRI. Orwat S; Diller GP; Kaleschke G; Kerckhoff G; Kempny A; Radke RM; Buerke B; Burg M; Schülke C; Baumgartner H Heart; 2014 Dec; 100(24):1933-8. PubMed ID: 25060755 [TBL] [Abstract][Full Text] [Related]
8. Feasibility of cardiovascular magnetic resonance to assess the orifice area of aortic bioprostheses. von Knobelsdorff-Brenkenhoff F; Rudolph A; Wassmuth R; Bohl S; Buschmann EE; Abdel-Aty H; Dietz R; Schulz-Menger J Circ Cardiovasc Imaging; 2009 Sep; 2(5):397-404, 2 p following 404. PubMed ID: 19808628 [TBL] [Abstract][Full Text] [Related]
9. Evaluation of aortic root for definition of prosthesis size by magnetic resonance imaging and cardiac computed tomography: implications for transcatheter aortic valve implantation. Koos R; Altiok E; Mahnken AH; Neizel M; Dohmen G; Marx N; Kühl H; Hoffmann R Int J Cardiol; 2012 Jul; 158(3):353-8. PubMed ID: 21315460 [TBL] [Abstract][Full Text] [Related]
10. Aortic regurgitation index defines severity of peri-prosthetic regurgitation and predicts outcome in patients after transcatheter aortic valve implantation. Sinning JM; Hammerstingl C; Vasa-Nicotera M; Adenauer V; Lema Cachiguango SJ; Scheer AC; Hausen S; Sedaghat A; Ghanem A; Müller C; Grube E; Nickenig G; Werner N J Am Coll Cardiol; 2012 Mar; 59(13):1134-41. PubMed ID: 22440213 [TBL] [Abstract][Full Text] [Related]
17. Haemodynamic evaluation of aortic regurgitation after transcatheter aortic valve implantation using cardiovascular magnetic resonance. Sherif MA; Abdel-Wahab M; Beurich HW; Stöcker B; Zachow D; Geist V; Tölg R; Richardt G EuroIntervention; 2011 May; 7(1):57-63. PubMed ID: 21550904 [TBL] [Abstract][Full Text] [Related]
18. Morphological and Functional Evaluation of Quadricuspid Aortic Valves Using Cardiac Computed Tomography. Song I; Park JA; Choi BH; Ko SM; Shin JK; Chee HK; Kim JS Korean J Radiol; 2016; 17(4):463-71. PubMed ID: 27390538 [TBL] [Abstract][Full Text] [Related]
19. Multimodal assessment of the aortic annulus diameter: implications for transcatheter aortic valve implantation. Messika-Zeitoun D; Serfaty JM; Brochet E; Ducrocq G; Lepage L; Detaint D; Hyafil F; Himbert D; Pasi N; Laissy JP; Iung B; Vahanian A J Am Coll Cardiol; 2010 Jan; 55(3):186-94. PubMed ID: 20117398 [TBL] [Abstract][Full Text] [Related]
20. Prosthesis sizing for transcatheter aortic valve implantation--comparison of three dimensional transesophageal echocardiography with multislice computed tomography. Husser O; Holzamer A; Resch M; Endemann DH; Nunez J; Bodi V; Schmid C; Riegger GA; Gössmann H; Hamer O; Stroszczynski C; Luchner A; Hilker M; Hengstenberg C Int J Cardiol; 2013 Oct; 168(4):3431-8. PubMed ID: 23688431 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]