BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

219 related articles for article (PubMed ID: 22083761)

  • 1. 80-MHz intravascular ultrasound transducer using PMN-PT free-standing film.
    Li X; Wu W; Chung Y; Shih WY; Shih WH; Zhou Q; Shung KK
    IEEE Trans Ultrason Ferroelectr Freq Control; 2011 Nov; 58(11):2281-8. PubMed ID: 22083761
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Micromachined PIN-PMN-PT crystal composite transducer for high-frequency intravascular ultrasound (IVUS) imaging.
    Li X; Ma T; Tian J; Han P; Zhou Q; Shung KK
    IEEE Trans Ultrason Ferroelectr Freq Control; 2014 Jul; 61(7):1171-8. PubMed ID: 24960706
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Focused intravascular ultrasonic probe using dimpled transducer elements.
    Chen Y; Qiu WB; Lam KH; Liu BQ; Jiang XP; Zheng HR; Luo HS; Chan HL; Dai JY
    Ultrasonics; 2015 Feb; 56():227-31. PubMed ID: 25108608
    [TBL] [Abstract][Full Text] [Related]  

  • 4. High-Performance Ultrasound Needle Transducer Based on Modified PMN-PT Ceramic With Ultrahigh Clamped Dielectric Permittivity.
    Zhang Z; Li F; Chen R; Zhang T; Cao X; Zhang S; Shrout TR; Zheng H; Shung KK; Humayun MS; Qiu W; Zhou Q
    IEEE Trans Ultrason Ferroelectr Freq Control; 2018 Feb; 65(2):223-230. PubMed ID: 29389654
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Transducer for harmonic intravascular ultrasound imaging.
    Vos HJ; Frijlink ME; Droog E; Goertz DE; Blacquière G; Gisolf A; de Jong N; van der Steen AF
    IEEE Trans Ultrason Ferroelectr Freq Control; 2005 Dec; 52(12):2418-22. PubMed ID: 16463509
    [TBL] [Abstract][Full Text] [Related]  

  • 6. PMN-PT Single Crystal Ultrasonic Transducer With Half-Concave Geometric Design for IVUS Imaging.
    Fei C; Yang Y; Guo F; Lin P; Chen Q; Zhou Q; Sun L
    IEEE Trans Biomed Eng; 2018 Sep; 65(9):2087-2092. PubMed ID: 29989942
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Lead-free BNT composite film for high-frequency broadband ultrasonic transducer applications.
    Yan X; Ji H; Lam KH; Chen R; Zheng F; Ren W; Zhou Q; Shung KK
    IEEE Trans Ultrason Ferroelectr Freq Control; 2013 Jul; 60(7):1533-7. PubMed ID: 25004521
    [TBL] [Abstract][Full Text] [Related]  

  • 8. PMN-PT single crystal, high-frequency ultrasonic needle transducers for pulsed-wave Doppler application.
    Zhou Q; Xu X; Gottlieb EJ; Sun L; Cannata JM; Ameri H; Humayun MS; Han P; Shung KK
    IEEE Trans Ultrason Ferroelectr Freq Control; 2007 Mar; 54(3):668-75. PubMed ID: 17375836
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A novel dual-frequency imaging method for intravascular ultrasound applications.
    Qiu W; Chen Y; Wong CM; Liu B; Dai J; Zheng H
    Ultrasonics; 2015 Mar; 57():31-5. PubMed ID: 25454093
    [TBL] [Abstract][Full Text] [Related]  

  • 10. (100)-Textured KNN-based thick film with enhanced piezoelectric property for intravascular ultrasound imaging.
    Zhu B; Zhang Z; Ma T; Yang X; Li Y; Shung KK; Zhou Q
    Appl Phys Lett; 2015 Apr; 106(17):173504. PubMed ID: 25991874
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Lead-free KNLNT piezoelectric ceramics for high-frequency ultrasonic transducer application.
    Wu DW; Chen RM; Zhou QF; Shung KK; Lin DM; Chan HL
    Ultrasonics; 2009 Mar; 49(3):395-8. PubMed ID: 19121835
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Fabrication and Characterization of High-Frequency Ultrasound Transducers Based on Lead-Free BNT-BT Tape-Casting Thick Film.
    Zhang J; Ren W; Liu Y; Wu X; Fei C; Quan Y; Zhou Q
    Sensors (Basel); 2018 Sep; 18(9):. PubMed ID: 30235869
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Silver Doped 0.9PMN-PT-0.1PZT Composite Films for very High Frequency Ultrasonic Transducer Applications.
    Hsu HS; Benjauthrit V; Wei Q; Huang Y; Zhou Q; Shung KK
    Appl Phys A Mater Sci Process; 2013 May; 111(2):459-463. PubMed ID: 23814408
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Phantom evaluation of stacked-type dual-frequency 1-3 composite transducers: A feasibility study on intracavitary acoustic angiography.
    Kim J; Li S; Kasoji S; Dayton PA; Jiang X
    Ultrasonics; 2015 Dec; 63():7-15. PubMed ID: 26112426
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Oblong-Shaped-Focused Transducers for Intravascular Ultrasound Imaging.
    Lee J; Jang J; Chang JH
    IEEE Trans Biomed Eng; 2017 Mar; 64(3):671-680. PubMed ID: 27244714
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Modulated Excitation Imaging System for Intravascular Ultrasound.
    Qiu W; Wang X; Chen Y; Fu Q; Su M; Zhang L; Xia J; Dai J; Zhang Y; Zheng H
    IEEE Trans Biomed Eng; 2017 Aug; 64(8):1935-1942. PubMed ID: 27893376
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Lead-free intravascular ultrasound transducer using BZT-50BCT ceramics.
    Yan X; Lam KH; Li X; Chen R; Ren W; Ren X; Zhou Q; Shung KK
    IEEE Trans Ultrason Ferroelectr Freq Control; 2013 Jun; 60(6):1272-6. PubMed ID: 25004492
    [TBL] [Abstract][Full Text] [Related]  

  • 18. PMN-PT single-crystal high-frequency kerfless phased array.
    Chen R; Cabrera-Munoz NE; Lam KH; Hsu HS; Zheng F; Zhou Q; Shung KK
    IEEE Trans Ultrason Ferroelectr Freq Control; 2014 Jun; 61(6):1033-41. PubMed ID: 24859667
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Polyurea thin film ultrasonic transducers for nondestructive testing and medical imaging.
    Nakazawa M; Kosugi T; Nagatsuka H; Maezawa A; Nakamura K; Ueha S
    IEEE Trans Ultrason Ferroelectr Freq Control; 2007 Oct; 54(10):2165-74. PubMed ID: 18019256
    [TBL] [Abstract][Full Text] [Related]  

  • 20. High Frequency PMN-PT 1-3 Composite Transducer for Ultrasonic Imaging Application.
    Sun P; Wang G; Wu D; Zhu B; Hu C; Liu C; Djuth FT; Zhou Q; Shung KK
    Ferroelectrics; 2010; 408(1):120-128. PubMed ID: 21869845
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.