  • 1. Effects of voxel size and iterative reconstruction parameters on the spatial resolution of 99mTc SPECT/CT.
    Kappadath SC
    J Appl Clin Med Phys; 2011 Nov; 12(4):3459. PubMed ID: 22089002
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Impact of reconstruction parameters on spatial resolution and its comparison between cadmium-zinc-telluride SPECT/CT and conventional SPECT/CT.
    Wang M; Dong S; Zhang R; Sun D; Wang S; Shen Y; Li N; Wang P; Tan J; Meng Z; Jia Q
    Nucl Med Commun; 2022 Jan; 43(1):8-16. PubMed ID: 34559760
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Quantitative simultaneous 111In∕99mTc SPECT-CT of osteomyelitis.
    Cervo M; Gerbaudo VH; Park MA; Moore SC
    Med Phys; 2013 Aug; 40(8):082501. PubMed ID: 23927346
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Correction of photon attenuation and collimator response for a body-contouring SPECT/CT imaging system.
    Seo Y; Wong KH; Sun M; Franc BL; Hawkins RA; Hasegawa BH
    J Nucl Med; 2005 May; 46(5):868-77. PubMed ID: 15872362
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Automatic estimation of detector radial position for contoured SPECT acquisition using CT images on a SPECT/CT system.
    Liu RR; Erwin WD
    Med Phys; 2006 Aug; 33(8):2800-8. PubMed ID: 16964856
    [TBL] [Abstract][Full Text] [Related]  

  • 6. ALBIRA: a small animal PET∕SPECT∕CT imaging system.
    Sánchez F; Orero A; Soriano A; Correcher C; Conde P; González A; Hernández L; Moliner L; Rodríguez-Alvarez MJ; Vidal LF; Benlloch JM; Chapman SE; Leevy WM
    Med Phys; 2013 May; 40(5):051906. PubMed ID: 23635276
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Fast Monte Carlo based joint iterative reconstruction for simultaneous 99mTc/ 123I SPECT imaging.
    Ouyang J; El Fakhri G; Moore SC
    Med Phys; 2007 Aug; 34(8):3263-72. PubMed ID: 17879789
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Impacts of acquisition and reconstruction parameters on the absolute technetium quantification of the cadmium-zinc-telluride-based SPECT/CT system: a phantom study.
    Zhang R; Wang M; Zhou Y; Wang S; Shen Y; Li N; Wang P; Tan J; Meng Z; Jia Q
    EJNMMI Phys; 2021 Sep; 8(1):66. PubMed ID: 34568990
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Iterative image reconstruction with polar coordinate discretized system matrix for optical CT radiochromic gel dosimetry.
    Collins S; Ogilvy A; Huang D; Hare W; Hilts M; Jirasek A
    Med Phys; 2023 Oct; 50(10):6334-6353. PubMed ID: 37190786
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Effects of ray profile modeling on resolution recovery in clinical CT.
    Hofmann C; Knaup M; Kachelrieß M
    Med Phys; 2014 Feb; 41(2):021907. PubMed ID: 24506628
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Design of a dual-resolution collimator for preclinical cardiac SPECT with a stationary triple-detector system.
    Moore SC; Park MA; Liu Z; Lyon MC; Johnson LC; Lushear VH; Westberg JG; Metzler SD
    Med Phys; 2016 Dec; 43(12):6336. PubMed ID: 27908172
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Nonuniform transmission in brain SPECT using 201Tl, 153Gd, and 99mTc static line sources: anthropomorphic dosimetry studies and influence on brain quantification.
    Van Laere K; Koole M; Kauppinen T; Monsieurs M; Bouwens L; Dierck R
    J Nucl Med; 2000 Dec; 41(12):2051-62. PubMed ID: 11138692
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Performance evaluation of OSEM reconstruction algorithm incorporating three-dimensional distance-dependent resolution compensation for brain SPECT: a simulation study.
    Yokoi T; Shinohara H; Onishi H
    Ann Nucl Med; 2002 Feb; 16(1):11-8. PubMed ID: 11922203
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Comparison of different types of commercial filtered backprojection and ordered-subset expectation maximization SPECT reconstruction software.
    Seret A; Forthomme J
    J Nucl Med Technol; 2009 Sep; 37(3):179-87. PubMed ID: 19726808
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Comparison of advanced iterative reconstruction methods for SPECT/CT.
    Knoll P; Kotalova D; Köchle G; Kuzelka I; Minear G; Mirzaei S; Sámal M; Zadrazil L; Bergmann H
    Z Med Phys; 2012 Feb; 22(1):58-69. PubMed ID: 21723716
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Clinical evaluation of reducing acquisition time on single-photon emission computed tomography image quality using proprietary resolution recovery software.
    Aldridge MD; Waddington WW; Dickson JC; Prakash V; Ell PJ; Bomanji JB
    Nucl Med Commun; 2013 Nov; 34(11):1116-23. PubMed ID: 24056385
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Evaluation of Iterative Reconstruction Method and Attenuation Correction in Brain Dopamine Transporter SPECT Using an Anthropomorphic Striatal Phantom.
    Maebatake A; Imamura A; Kodera Y; Yamashita Y; Himuro K; Baba S; Miwa K; Sasaki M
    Asia Ocean J Nucl Med Biol; 2016; 4(2):72-80. PubMed ID: 27408895
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Optimization of iterative reconstruction parameters with attenuation correction, scatter correction and resolution recovery in myocardial perfusion SPECT/CT.
    Okuda K; Nakajima K; Yamada M; Wakabayashi H; Ichikawa H; Arai H; Matsuo S; Taki J; Hashimoto M; Kinuya S
    Ann Nucl Med; 2014 Jan; 28(1):60-8. PubMed ID: 24214735
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Resolution-recovery-embedded image reconstruction for a high-resolution animal SPECT system.
    Zeraatkar N; Sajedi S; Farahani MH; Arabi H; Sarkar S; Ghafarian P; Rahmim A; Ay MR
    Phys Med; 2014 Nov; 30(7):774-81. PubMed ID: 24986422
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Optimization of iterative reconstruction parameters with 3-dimensional resolution recovery, scatter and attenuation correction in ¹²³I-FP-CIT SPECT.
    Matsutomo N; Nagaki A; Yamao F; Sasaki M
    Ann Nucl Med; 2015 Aug; 29(7):636-42. PubMed ID: 25997807
    [TBL] [Abstract][Full Text] [Related]  