784 related articles for article (PubMed ID: 22092540)
1. Stability of cp-Ti and Ti-6Al-4V alloy for dental implants as a function of saliva pH - an electrochemical study.
Barão VA; Mathew MT; Assunção WG; Yuan JC; Wimmer MA; Sukotjo C
Clin Oral Implants Res; 2012 Sep; 23(9):1055-62. PubMed ID: 22092540
[TBL] [Abstract][Full Text] [Related]
2. Electrochemical impedance spectroscopy study of Ti-6Al-4V alloy in artificial saliva with fluoride and/or bovine albumin.
Huang HH; Lee TH
Dent Mater; 2005 Aug; 21(8):749-55. PubMed ID: 15878783
[TBL] [Abstract][Full Text] [Related]
3. Comparative corrosion study of Ti-Ta alloys for dental applications.
Mareci D; Chelariu R; Gordin DM; Ungureanu G; Gloriant T
Acta Biomater; 2009 Nov; 5(9):3625-39. PubMed ID: 19508903
[TBL] [Abstract][Full Text] [Related]
4. Attachment of Porphyromonas gingivalis to corroded commercially pure titanium and titanium-aluminum-vanadium alloy.
Barão VA; Yoon CJ; Mathew MT; Yuan JC; Wu CD; Sukotjo C
J Periodontol; 2014 Sep; 85(9):1275-82. PubMed ID: 24444400
[TBL] [Abstract][Full Text] [Related]
5. Electrochemical studies of the corrosion behaviour of titanium and the Ti-6Al-4V alloy using electrochemical impedance spectroscopy.
Grosgogeat B; Boinet M; Dalard F; Lissac M
Biomed Mater Eng; 2004; 14(3):323-31. PubMed ID: 15299244
[TBL] [Abstract][Full Text] [Related]
6. Influence of corrosion on lipopolysaccharide affinity for two different titanium materials.
Barão VA; Mathew MT; Yuan JC; Knoernschild KL; Assunção WG; Wimmer MA; Sukotjo C
J Prosthet Dent; 2013 Dec; 110(6):462-70. PubMed ID: 24161259
[TBL] [Abstract][Full Text] [Related]
7. Surface roughness and fatigue performance of commercially pure titanium and Ti-6Al-4V alloy after different polishing protocols.
Guilherme AS; Henriques GE; Zavanelli RA; Mesquita MF
J Prosthet Dent; 2005 Apr; 93(4):378-85. PubMed ID: 15798689
[TBL] [Abstract][Full Text] [Related]
8. The effect of fluoride ions on the corrosion behaviour of Ti metal, and Ti6-Al-7Nb and Ti-6Al-4V alloys in artificial saliva.
Milošev I; Kapun B; Selih VS
Acta Chim Slov; 2013; 60(3):543-55. PubMed ID: 24169708
[TBL] [Abstract][Full Text] [Related]
9. Electrochemical behavior of titanium in artificial saliva: influence of pH.
Abey S; Mathew MT; Lee DJ; Knoernschild KL; Wimmer MA; Sukotjo C
J Oral Implantol; 2014 Feb; 40(1):3-10. PubMed ID: 22103963
[TBL] [Abstract][Full Text] [Related]
10. Electrochemical corrosion of titanium and titanium-based alloys.
Kuphasuk C; Oshida Y; Andres CJ; Hovijitra ST; Barco MT; Brown DT
J Prosthet Dent; 2001 Feb; 85(2):195-202. PubMed ID: 11208211
[TBL] [Abstract][Full Text] [Related]
11. The electrochemical behavior and surface analysis of Ti50Ni47.2Co2.8 alloy for orthodontic use.
Wang QY; Zheng YF
Dent Mater; 2008 Sep; 24(9):1207-11. PubMed ID: 18336899
[TBL] [Abstract][Full Text] [Related]
12. Titanium surface topography after brushing with fluoride and fluoride-free toothpaste simulating 10 years of use.
Fais LM; Fernandes-Filho RB; Pereira-da-Silva MA; Vaz LG; Adabo GL
J Dent; 2012 Apr; 40(4):265-75. PubMed ID: 22265989
[TBL] [Abstract][Full Text] [Related]
13. The effect of Pt and Pd alloying additions on the corrosion behavior of titanium in fluoride-containing environments.
Nakagawa M; Matono Y; Matsuya S; Udoh K; Ishikawa K
Biomaterials; 2005 May; 26(15):2239-46. PubMed ID: 15585225
[TBL] [Abstract][Full Text] [Related]
14. Reduced corrosion of CP Ti and Ti-6A1-4V alloy endosseous dental implants after glow-discharge treatment: a preliminary report.
Vargas E; Baier RE; Meyer AE
Int J Oral Maxillofac Implants; 1992; 7(3):338-44. PubMed ID: 1289259
[TBL] [Abstract][Full Text] [Related]
15. Corrosion-fatigue life of commercially pure titanium and Ti-6Al-4V alloys in different storage environments.
Zavanelli RA; Pessanha Henriques GE; Ferreira I; De Almeida Rollo JM
J Prosthet Dent; 2000 Sep; 84(3):274-9. PubMed ID: 11005899
[TBL] [Abstract][Full Text] [Related]
16. Corrosion behavior of biomedical Ti-24Nb-4Zr-8Sn alloy in different simulated body solutions.
Bai Y; Hao YL; Li SJ; Hao YQ; Yang R; Prima F
Mater Sci Eng C Mater Biol Appl; 2013 May; 33(4):2159-67. PubMed ID: 23498244
[TBL] [Abstract][Full Text] [Related]
17. [Effect of fluoride ion on corrosion of two dental titanium alloys].
Cao BW; Chen L
Hua Xi Kou Qiang Yi Xue Za Zhi; 2010 Jun; 28(3):261-4. PubMed ID: 20635653
[TBL] [Abstract][Full Text] [Related]
18. The role of lipopolysaccharide on the electrochemical behavior of titanium.
Barão VA; Mathew MT; Assunção WG; Yuan JC; Wimmer MA; Sukotjo C
J Dent Res; 2011 May; 90(5):613-8. PubMed ID: 21335537
[TBL] [Abstract][Full Text] [Related]
19. Fit of cast commercially pure titanium and Ti-6Al-4V alloy crowns before and after marginal refinement by electrical discharge machining.
Contreras EF; Henriques GE; Giolo SR; Nobilo MA
J Prosthet Dent; 2002 Nov; 88(5):467-72. PubMed ID: 12473994
[TBL] [Abstract][Full Text] [Related]
20. The development of Ti alloys for dental implant with high corrosion resistance and mechanical strength.
Yamazoe J; Nakagawa M; Matono Y; Takeuchi A; Ishikawa K
Dent Mater J; 2007 Mar; 26(2):260-7. PubMed ID: 17621943
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]