These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

96 related articles for article (PubMed ID: 22095172)

  • 1. Stationarity stopping criterion for matching pursuit-framework and encephalographic illustration.
    Kipiński L
    Biol Cybern; 2011 Dec; 105(5-6):287-90. PubMed ID: 22095172
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Application of modern tests for stationarity to single-trial MEG data: transferring powerful statistical tools from econometrics to neuroscience.
    Kipiński L; König R; Sielużycki C; Kordecki W
    Biol Cybern; 2011 Oct; 105(3-4):183-95. PubMed ID: 22095173
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Identification and elimination of cardiac contribution in single-trial magnetoencephalographic signals.
    Samonas M; Petrou M; Ioannides AA
    IEEE Trans Biomed Eng; 1997 May; 44(5):386-93. PubMed ID: 9125823
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Multichannel matching pursuit validation and clustering--a simulation and empirical study.
    Lelic D; Gratkowski M; Hennings K; Drewes AM
    J Neurosci Methods; 2011 Mar; 196(1):190-200. PubMed ID: 21187116
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A multiresolution framework to MEG/EEG source imaging.
    Gavit L; Baillet S; Mangin JF; Pescatore J; Garnero L
    IEEE Trans Biomed Eng; 2001 Oct; 48(10):1080-7. PubMed ID: 11585031
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Detecting millisecond-range coupling delays between brainwaves in terms of power correlations by magnetoencephalography.
    Dabek J; Nikulin VV; Ilmoniemi RJ
    J Neurosci Methods; 2014 Sep; 235():10-24. PubMed ID: 24983131
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Signal space separation algorithm and its application on suppressing artifacts caused by vagus nerve stimulation for magnetoencephalography recordings.
    Song T; Cui L; Gaa K; Feffer L; Taulu S; Lee RR; Huang M
    J Clin Neurophysiol; 2009 Dec; 26(6):392-400. PubMed ID: 19952563
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A comparison of methods for separation of transient and oscillatory signals in EEG.
    Jmail N; Gavaret M; Wendling F; Kachouri A; Hamadi G; Badier JM; Bénar CG
    J Neurosci Methods; 2011 Aug; 199(2):273-89. PubMed ID: 21596061
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Numerical aspects of spatio-temporal current density reconstruction from EEG-/MEG-data.
    Schmitt U; Louis AK; Darvas F; Buchner H; Fuchs M
    IEEE Trans Med Imaging; 2001 Apr; 20(4):314-24. PubMed ID: 11370898
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Consensus Matching Pursuit for multi-trial EEG signals.
    Bénar CG; Papadopoulo T; Torrésani B; Clerc M
    J Neurosci Methods; 2009 May; 180(1):161-70. PubMed ID: 19427543
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A resampling method for estimating the signal subspace of spatio-temporal EEG/MEG data.
    Maris E
    IEEE Trans Biomed Eng; 2003 Aug; 50(8):935-49. PubMed ID: 12892321
    [TBL] [Abstract][Full Text] [Related]  

  • 12. MEG and EEG source localization in beamspace.
    Rodríguez-Rivera A; Baryshnikov BV; Van Veen BD; Wakai RT
    IEEE Trans Biomed Eng; 2006 Mar; 53(3):430-41. PubMed ID: 16532769
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Minimum Overlap Component Analysis (MOCA) of EEG/MEG data for more than two sources.
    Nolte G; Marzetti L; Valdes Sosa P
    J Neurosci Methods; 2009 Sep; 183(1):72-6. PubMed ID: 19596027
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Maximum contrast beamformer for electromagnetic mapping of brain activity.
    Chen YS; Cheng CY; Hsieh JC; Chen LF
    IEEE Trans Biomed Eng; 2006 Sep; 53(9):1765-74. PubMed ID: 16941832
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Integrated MEG/EEG and fMRI model based on neural masses.
    Babajani A; Soltanian-Zadeh H
    IEEE Trans Biomed Eng; 2006 Sep; 53(9):1794-801. PubMed ID: 16941835
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Time-frequency filtering of MEG signals with matching pursuit.
    Gratkowski M; Haueisen J; Arendt-Nielsen L; Chen AC; Zanow F
    J Physiol Paris; 2006 Jan; 99(1):47-57. PubMed ID: 16039100
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Single-trial reconstruction of auditory evoked magnetic fields by means of Template Matching Pursuit.
    Jörn M; Sielużycki C; Matysiak MA; Zygierewicz J; Scheich H; Durka PJ; König R
    J Neurosci Methods; 2011 Jul; 199(1):119-28. PubMed ID: 21536070
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Describing the nonstationarity level of neurological signals based on quantifications of time-frequency representation.
    Tong S; Li Z; Zhu Y; Thakor NV
    IEEE Trans Biomed Eng; 2007 Oct; 54(10):1780-5. PubMed ID: 17926676
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Spectral analysis for nonstationary and nonlinear systems: a discrete-time-model-based approach.
    He F; Billings SA; Wei HL; Sarrigiannis PG; Zhao Y
    IEEE Trans Biomed Eng; 2013 Aug; 60(8):2233-41. PubMed ID: 23508247
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Time-shift denoising source separation.
    de Cheveigné A
    J Neurosci Methods; 2010 May; 189(1):113-20. PubMed ID: 20298717
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.