BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

331 related articles for article (PubMed ID: 22098886)

  • 1. Wear resistance of experimental titanium alloys for dental applications.
    Faria AC; Rodrigues RC; Claro AP; da Gloria Chiarello de Mattos M; Ribeiro RF
    J Mech Behav Biomed Mater; 2011 Nov; 4(8):1873-9. PubMed ID: 22098886
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Wear and friction properties of experimental Ti-Si-Zr alloys for biomedical applications.
    Tkachenko S; Datskevich O; Kulak L; Jacobson S; Engqvist H; Persson C
    J Mech Behav Biomed Mater; 2014 Nov; 39():61-72. PubMed ID: 25105238
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Development of binary and ternary titanium alloys for dental implants.
    Cordeiro JM; Beline T; Ribeiro ALR; Rangel EC; da Cruz NC; Landers R; Faverani LP; Vaz LG; Fais LMG; Vicente FB; Grandini CR; Mathew MT; Sukotjo C; Barão VAR
    Dent Mater; 2017 Nov; 33(11):1244-1257. PubMed ID: 28778495
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Study of the surface wear resistance and biological properties of the Ti-Zr-Nb-Sn alloy for dental restoration.
    Hu X; Wei Q; Li CY; Deng JY; Liu S; Zhang LY
    Biomed Mater; 2010 Oct; 5(5):054107. PubMed ID: 20876964
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Hardness and microstructure of Ti-15Mo-5Zr-3Al alloy for dental casting.
    Kochi M; Koizumi H; Murakami M; Kikuchi H; Matsumura H; Yoneyama T
    Acta Odontol Scand; 2011 Nov; 69(6):328-33. PubMed ID: 21426269
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Preparation, structural, microstructural, mechanical and cytotoxic characterization of as-cast Ti-25Ta-Zr alloys.
    Kuroda PAB; de Freitas Quadros F; Sousa KDSJ; Donato TAG; de Araújo RO; Grandini CR
    J Mater Sci Mater Med; 2020 Jan; 31(2):19. PubMed ID: 31965338
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Mechanical, physical, and chemical characterization of Ti-35Nb-5Zr and Ti-35Nb-10Zr casting alloys.
    Ribeiro AL; Junior RC; Cardoso FF; Filho RB; Vaz LG
    J Mater Sci Mater Med; 2009 Aug; 20(8):1629-36. PubMed ID: 19337820
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Effect of molybdenum on structure, microstructure and mechanical properties of biomedical Ti-20Zr-Mo alloys.
    Kuroda PAB; Buzalaf MAR; Grandini CR
    Mater Sci Eng C Mater Biol Appl; 2016 Oct; 67():511-515. PubMed ID: 27287149
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Influence of lubricating conditions on the two-body wear behavior and hardness of titanium alloys for biomedical applications.
    Yilmaz EÇ
    Comput Methods Biomech Biomed Engin; 2020 Dec; 23(16):1377-1386. PubMed ID: 32772856
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Experimental titanium alloys for dental applications.
    Faria AC; Rodrigues RC; Rosa AL; Ribeiro RF
    J Prosthet Dent; 2014 Dec; 112(6):1448-60. PubMed ID: 25088209
    [TBL] [Abstract][Full Text] [Related]  

  • 11. The effect of the solute on the structure, selected mechanical properties, and biocompatibility of Ti-Zr system alloys for dental applications.
    Correa DR; Vicente FB; Donato TA; Arana-Chavez VE; Buzalaf MA; Grandini CR
    Mater Sci Eng C Mater Biol Appl; 2014 Jan; 34():354-9. PubMed ID: 24268269
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Wear resistance of a pressable low-fusing ceramic opposed by dental alloys.
    Faria ACL; de Oliveira AA; Alves Gomes É; Silveira Rodrigues RC; Faria Ribeiro R
    J Mech Behav Biomed Mater; 2014 Apr; 32():46-51. PubMed ID: 24412716
    [TBL] [Abstract][Full Text] [Related]  

  • 13. In vitro wear assessment of titanium alloy teeth.
    Ohkubo C; Shimura I; Aoki T; Hanatani S; Hosoi T; Okabe T
    J Prosthodont; 2002 Dec; 11(4):263-9. PubMed ID: 12501140
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Microstructure and selected mechanical properties of aged Ti-15Zr-based alloys for biomedical applications.
    Correa DRN; Kuroda PAB; Lourenço ML; Buzalaf MAR; Mendoza ME; Archanjo BS; Achete CA; Rocha LA; Grandini CR
    Mater Sci Eng C Mater Biol Appl; 2018 Oct; 91():762-771. PubMed ID: 30033311
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Structure, castability and mechanical properties of commercially pure and alloyed titanium cast in graphite mould.
    Cheng WW; Ju CP; Lin JH
    J Oral Rehabil; 2007 Jul; 34(7):528-40. PubMed ID: 17559621
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Nanotube nucleation phenomena on Ti-25Ta-xZr alloys for implants using ATO technique.
    Kim HJ; Jeong YH; Brantley WA; Choe HC
    J Nanosci Nanotechnol; 2014 Oct; 14(10):7569-73. PubMed ID: 25942827
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Enhancement of the electrochemical behaviour and biological performance of Ti-25Ta-5Zr alloy by thermo-mechanical processing.
    Cimpean A; Vasilescu E; Drob P; Cinca I; Vasilescu C; Anastasescu M; Mitran V; Drob SI
    Mater Sci Eng C Mater Biol Appl; 2014 May; 38():127-42. PubMed ID: 24656361
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Microstructure, mechanical properties, and preliminary biocompatibility evaluation of binary Ti-Zr alloys for dental application.
    Wang B; Ruan W; Liu J; Zhang T; Yang H; Ruan J
    J Biomater Appl; 2019 Jan; 33(6):766-775. PubMed ID: 30396325
    [TBL] [Abstract][Full Text] [Related]  

  • 19. The influence of heat treatment and role of boron on sliding wear behaviour of β-type Ti-35Nb-7.2Zr-5.7Ta alloy in dry condition and in simulated body fluids.
    Majumdar P; Singh SB; Chakraborty M
    J Mech Behav Biomed Mater; 2011 Apr; 4(3):284-97. PubMed ID: 21316616
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Wear resistance of experimental Ti-Cu alloys.
    Ohkubo C; Shimura I; Aoki T; Hanatani S; Hosoi T; Hattori M; Oda Y; Okabe T
    Biomaterials; 2003 Sep; 24(20):3377-81. PubMed ID: 12809765
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 17.