BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

126 related articles for article (PubMed ID: 22098910)

  • 1. Cell adhesion to plasma electrolytic oxidation (PEO) titania coatings, assessed using a centrifuging technique.
    Robinson HJ; Markaki AE; Collier CA; Clyne TW
    J Mech Behav Biomed Mater; 2011 Nov; 4(8):2103-12. PubMed ID: 22098910
    [TBL] [Abstract][Full Text] [Related]  

  • 2. In vitro evaluation of cell proliferation and collagen synthesis on titanium following plasma electrolytic oxidation.
    Whiteside P; Matykina E; Gough JE; Skeldon P; Thompson GE
    J Biomed Mater Res A; 2010 Jul; 94(1):38-46. PubMed ID: 20091708
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Microstructure and mechanical properties of plasma sprayed HA/YSZ/Ti-6Al-4V composite coatings.
    Khor KA; Gu YW; Pan D; Cheang P
    Biomaterials; 2004 Aug; 25(18):4009-17. PubMed ID: 15046891
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Bond strength determination of hydroxyapatite coatings on Ti-6Al-4V substrates using the LAser Shock Adhesion Test (LASAT).
    Guipont V; Jeandin M; Bansard S; Khor KA; Nivard M; Berthe L; Cuq-Lelandais JP; Boustie M
    J Biomed Mater Res A; 2010 Dec; 95(4):1096-104. PubMed ID: 20878900
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Titania-hydroxyapatite nanocomposite coatings support human mesenchymal stem cells osteogenic differentiation.
    Dimitrievska S; Bureau MN; Antoniou J; Mwale F; Petit A; Lima RS; Marple BR
    J Biomed Mater Res A; 2011 Sep; 98(4):576-88. PubMed ID: 21702080
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Osseointegration improvement by plasma electrolytic oxidation of modified titanium alloys surfaces.
    Echeverry-Rendón M; Galvis O; Quintero Giraldo D; Pavón J; López-Lacomba JL; Jiménez-Piqué E; Anglada M; Robledo SM; Castaño JG; Echeverría F
    J Mater Sci Mater Med; 2015 Feb; 26(2):72. PubMed ID: 25631270
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Nanocrystalline hydroxyapatite/titania coatings on titanium improves osteoblast adhesion.
    Sato M; Aslani A; Sambito MA; Kalkhoran NM; Slamovich EB; Webster TJ
    J Biomed Mater Res A; 2008 Jan; 84(1):265-72. PubMed ID: 17607739
    [TBL] [Abstract][Full Text] [Related]  

  • 8. In vitro biological response of plasma electrolytically oxidized and plasma-sprayed hydroxyapatite coatings on Ti-6Al-4V alloy.
    Yeung WK; Reilly GC; Matthews A; Yerokhin A
    J Biomed Mater Res B Appl Biomater; 2013 Aug; 101(6):939-49. PubMed ID: 23529912
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Compositionally graded hydroxyapatite/tricalcium phosphate coating on Ti by laser and induction plasma.
    Roy M; Balla VK; Bandyopadhyay A; Bose S
    Acta Biomater; 2011 Feb; 7(2):866-73. PubMed ID: 20854939
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Cell response to plasma electrolytic oxidation surface-modified low-modulus β-type titanium alloys.
    Tanase CE; Golozar M; Best SM; Brooks RA
    Colloids Surf B Biointerfaces; 2019 Apr; 176():176-184. PubMed ID: 30616108
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Hierarchically porous surface of HA-sandblasted Ti implant screw using the plasma electrolytic oxidation: Physical characterization and biological responses.
    Choe Y; Li CJ; Yeo DH; Kim YJ; Lee JH; Lee HH
    J Biomater Appl; 2024 May; 38(10):1100-1117. PubMed ID: 38580320
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Novel sphene coatings on Ti-6Al-4V for orthopedic implants using sol-gel method.
    Wu C; Ramaswamy Y; Gale D; Yang W; Xiao K; Zhang L; Yin Y; Zreiqat H
    Acta Biomater; 2008 May; 4(3):569-76. PubMed ID: 18182336
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Enhanced osteoblast adhesion on hydrothermally treated hydroxyapatite/titania/poly(lactide-co-glycolide) sol-gel titanium coatings.
    Sato M; Slamovich EB; Webster TJ
    Biomaterials; 2005 Apr; 26(12):1349-57. PubMed ID: 15482822
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Production of hydroxyapatite layers on the plasma electrolytically oxidized surface of titanium alloys.
    Lugovskoy A; Lugovskoy S
    Mater Sci Eng C Mater Biol Appl; 2014 Oct; 43():527-32. PubMed ID: 25175246
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Characterization of the interface in the plasma-sprayed HA coating/Ti-6Al-4V implant system.
    Filiaggi MJ; Coombs NA; Pilliar RM
    J Biomed Mater Res; 1991 Oct; 25(10):1211-29. PubMed ID: 1667401
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Plasma-sprayed hydroxyapatite+titania composite bond coat for hydroxyapatite coating on titanium substrate.
    Lu YP; Li MS; Li ST; Wang ZG; Zhu RF
    Biomaterials; 2004 Aug; 25(18):4393-403. PubMed ID: 15046930
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Comparison of bone-implant interface shear strength of solid hydroxyapatite and hydroxyapatite-coated titanium implants.
    Hayashi K; Inadome T; Mashima T; Sugioka Y
    J Biomed Mater Res; 1993 May; 27(5):557-63. PubMed ID: 8314808
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Hydroxyapatite-TiO2 hybrid coating on Ti implants.
    Lee SH; Kim HW; Lee EJ; Li LH; Kim HE
    J Biomater Appl; 2006 Jan; 20(3):195-208. PubMed ID: 16364961
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Plasma electrolytic oxidation of titanium and improvement in osseointegration.
    Chung CJ; Su RT; Chu HJ; Chen HT; Tsou HK; He JL
    J Biomed Mater Res B Appl Biomater; 2013 Aug; 101(6):1023-30. PubMed ID: 23529975
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Plasma Electrolytic Oxidation of Titanium Implant Surfaces: Microgroove-Structures Improve Cellular Adhesion and Viability.
    Hartjen P; Hoffmann A; Henningsen A; Barbeck M; Kopp A; Kluwe L; Precht C; Quatela O; Gaudin R; Heiland M; Friedrich RE; Knipfer C; Grubeanu D; Smeets R; Jung O
    In Vivo; 2018; 32(2):241-247. PubMed ID: 29475905
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.