These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

116 related articles for article (PubMed ID: 22098910)

  • 41. Microstructures of plasma-sprayed hydroxyapatite-coated Ti-6Al-4V dental implants.
    Tufekci E; Brantley WA; Mitchell JC; McGlumphy EA
    Int J Oral Maxillofac Implants; 1997; 12(1):25-31. PubMed ID: 9048451
    [TBL] [Abstract][Full Text] [Related]  

  • 42. Surface modification of valve metals using plasma electrolytic oxidation for antibacterial applications: A review.
    Rizwan M; Alias R; Zaidi UZ; Mahmoodian R; Hamdi M
    J Biomed Mater Res A; 2018 Feb; 106(2):590-605. PubMed ID: 28975693
    [TBL] [Abstract][Full Text] [Related]  

  • 43. The effects of micro arc oxidation of gamma titanium aluminide surfaces on osteoblast adhesion and differentiation.
    Santiago-Medina P; Sundaram PA; Diffoot-Carlo N
    J Mater Sci Mater Med; 2014 Jun; 25(6):1577-87. PubMed ID: 24577944
    [TBL] [Abstract][Full Text] [Related]  

  • 44. Novel production method and in-vitro cell compatibility of porous Ti-6Al-4V alloy disk for hard tissue engineering.
    Bhattarai SR; Khalil KA; Dewidar M; Hwang PH; Yi HK; Kim HY
    J Biomed Mater Res A; 2008 Aug; 86(2):289-99. PubMed ID: 17957720
    [TBL] [Abstract][Full Text] [Related]  

  • 45. Functional Elements Coatings on the Plasma Electrolytic Oxidation-Treated Ti-6Al-4V Alloy by Electrochemical Precipitation Method.
    Kim SP; Choe HC
    J Nanosci Nanotechnol; 2019 Jul; 19(7):4344-4349. PubMed ID: 30765018
    [TBL] [Abstract][Full Text] [Related]  

  • 46. In vitro mechanical integrity of hydroxyapatite coatings on Ti-6Al-4V implants under shear loading.
    Zhang C; Leng Y; Chen J
    J Biomed Mater Res; 2001 Sep; 56(3):342-50. PubMed ID: 11372051
    [TBL] [Abstract][Full Text] [Related]  

  • 47. Preparation and properties of plasma electrolytic oxidation coating on sandblasted pure titanium by a combination treatment.
    Wang HY; Zhu RF; Lu YP; Xiao GY; Zhao XC; He K; Yuan YF; Li Y; Ma XN
    Mater Sci Eng C Mater Biol Appl; 2014 Sep; 42():657-64. PubMed ID: 25063166
    [TBL] [Abstract][Full Text] [Related]  

  • 48. PEO-generated Surfaces Support Attachment and Growth of Cells In Vitro with No Additional Benefit for Micro-roughness in Sa (0.2-4 μm).
    Jung O; Smeets R; Kopp A; Porchetta D; Hiester P; Heiland M; Friedrich RE; Precht C; Hanken H; Gröbe A; Hartjen P
    In Vivo; 2016; 30(1):27-33. PubMed ID: 26709125
    [TBL] [Abstract][Full Text] [Related]  

  • 49. Transmission electron microscopy of coatings formed by plasma electrolytic oxidation of titanium.
    Matykina E; Arrabal R; Skeldon P; Thompson GE
    Acta Biomater; 2009 May; 5(4):1356-66. PubMed ID: 19006685
    [TBL] [Abstract][Full Text] [Related]  

  • 50. Effects of topographical surface modifications of electron beam melted Ti-6Al-4V titanium on human fetal osteoblasts.
    Ponader S; Vairaktaris E; Heinl P; Wilmowsky CV; Rottmair A; Körner C; Singer RF; Holst S; Schlegel KA; Neukam FW; Nkenke E
    J Biomed Mater Res A; 2008 Mar; 84(4):1111-9. PubMed ID: 17685409
    [TBL] [Abstract][Full Text] [Related]  

  • 51. Thermal residual stresses near the interface between plasma-sprayed hydroxyapatite coating and titanium substrate: finite element analysis and synchrotron radiation measurements.
    Cofino B; Fogarassy P; Millet P; Lodini A
    J Biomed Mater Res A; 2004 Jul; 70(1):20-7. PubMed ID: 15174105
    [TBL] [Abstract][Full Text] [Related]  

  • 52. PEO coatings design for Mg-Ca alloy for cardiovascular stent and bone regeneration applications.
    Santos-Coquillat A; Esteban-Lucia M; Martinez-Campos E; Mohedano M; Arrabal R; Blawert C; Zheludkevich ML; Matykina E
    Mater Sci Eng C Mater Biol Appl; 2019 Dec; 105():110026. PubMed ID: 31546411
    [TBL] [Abstract][Full Text] [Related]  

  • 53. Cyclo-DfKRG peptide modulates in vitro and in vivo behavior of human osteoprogenitor cells on titanium alloys.
    Pallu S; Fricain JC; Bareille R; Bourget C; Dard M; Sewing A; Amédée J
    Acta Biomater; 2009 Nov; 5(9):3581-92. PubMed ID: 19467347
    [TBL] [Abstract][Full Text] [Related]  

  • 54. Modulation of the responses of human osteoblast-like cells to physiologic mechanical strains by biomaterial surfaces.
    Di Palma F; Guignandon A; Chamson A; Lafage-Proust MH; Laroche N; Peyroche S; Vico L; Rattner A
    Biomaterials; 2005 Jul; 26(20):4249-57. PubMed ID: 15683648
    [TBL] [Abstract][Full Text] [Related]  

  • 55. Bond strength, compositional, and structural properties of hydroxyapatite coating on Ti, ZrO2-coated Ti, and TPS-coated Ti substrate.
    Yang Y; Ong JL
    J Biomed Mater Res A; 2003 Mar; 64(3):509-16. PubMed ID: 12579565
    [TBL] [Abstract][Full Text] [Related]  

  • 56. Microstructure, bioactivity and osteoblast behavior of monoclinic zirconia coating with nanostructured surface.
    Wang G; Meng F; Ding C; Chu PK; Liu X
    Acta Biomater; 2010 Mar; 6(3):990-1000. PubMed ID: 19800425
    [TBL] [Abstract][Full Text] [Related]  

  • 57. [Preparation of hydroxyapatite-containing titania film on the surface of pure titanium by micro-arc oxidation technique].
    Chen J; Zhang F; Shi Y; Wang L; Yan F
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2008 Feb; 25(1):127-30. PubMed ID: 18435273
    [TBL] [Abstract][Full Text] [Related]  

  • 58. Fit of cast commercially pure titanium and Ti-6Al-4V alloy crowns before and after marginal refinement by electrical discharge machining.
    Contreras EF; Henriques GE; Giolo SR; Nobilo MA
    J Prosthet Dent; 2002 Nov; 88(5):467-72. PubMed ID: 12473994
    [TBL] [Abstract][Full Text] [Related]  

  • 59. Synthesis and properties of hydroxyapatite-containing porous titania coating on ultrafine-grained titanium by micro-arc oxidation.
    Yao ZQ; Ivanisenko Y; Diemant T; Caron A; Chuvilin A; Jiang JZ; Valiev RZ; Qi M; Fecht HJ
    Acta Biomater; 2010 Jul; 6(7):2816-25. PubMed ID: 20056173
    [TBL] [Abstract][Full Text] [Related]  

  • 60. Osteoblastlike cell adhesion on titanium surfaces modified by plasma nitriding.
    da Silva JS; Amico SC; Rodrigues AO; Barboza CA; Alves C; Croci AT
    Int J Oral Maxillofac Implants; 2011; 26(2):237-44. PubMed ID: 21483875
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 6.