These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

462 related articles for article (PubMed ID: 22102512)

  • 1. Simultaneous EEG and MEG source reconstruction in sparse electromagnetic source imaging.
    Ding L; Yuan H
    Hum Brain Mapp; 2013 Apr; 34(4):775-95. PubMed ID: 22102512
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Sparse electromagnetic source imaging using EEG and MEG.
    Ding L; Yuan H
    Annu Int Conf IEEE Eng Med Biol Soc; 2012; 2012():6224-7. PubMed ID: 23367351
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Investigation of EEG and MEG source imaging accuracy in reconstructing extended cortical sources.
    Ding L; Yuan H
    Annu Int Conf IEEE Eng Med Biol Soc; 2011; 2011():7013-6. PubMed ID: 22255953
    [TBL] [Abstract][Full Text] [Related]  

  • 4. L1-norm and L2-norm neuroimaging methods in reconstructing extended cortical sources from EEG.
    Ding L
    Annu Int Conf IEEE Eng Med Biol Soc; 2009; 2009():1922-5. PubMed ID: 19964567
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Estimation of neural dynamics from MEG/EEG cortical current density maps: application to the reconstruction of large-scale cortical synchrony.
    David O; Garnero L; Cosmelli D; Varela FJ
    IEEE Trans Biomed Eng; 2002 Sep; 49(9):975-87. PubMed ID: 12214887
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A new wavelet transform to sparsely represent cortical current densities for EEG/MEG inverse problems.
    Liao K; Zhu M; Ding L
    Comput Methods Programs Biomed; 2013 Aug; 111(2):376-88. PubMed ID: 23706527
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Monte Carlo simulation studies of EEG and MEG localization accuracy.
    Liu AK; Dale AM; Belliveau JW
    Hum Brain Mapp; 2002 May; 16(1):47-62. PubMed ID: 11870926
    [TBL] [Abstract][Full Text] [Related]  

  • 8. EEG/MEG source imaging using fMRI informed time-variant constraints.
    Xu J; Sheng J; Qian T; Luo YJ; Gao JH
    Hum Brain Mapp; 2018 Apr; 39(4):1700-1711. PubMed ID: 29293277
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Multimodal integration of EEG and MEG data: a simulation study with variable signal-to-noise ratio and number of sensors.
    Babiloni F; Babiloni C; Carducci F; Romani GL; Rossini PM; Angelone LM; Cincotti F
    Hum Brain Mapp; 2004 May; 22(1):52-62. PubMed ID: 15083526
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A technique to consider mismatches between fMRI and EEG/MEG sources for fMRI-constrained EEG/MEG source imaging: a preliminary simulation study.
    Im CH; Lee SY
    Phys Med Biol; 2006 Dec; 51(23):6005-21. PubMed ID: 17110766
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Sparsity enables estimation of both subcortical and cortical activity from MEG and EEG.
    Krishnaswamy P; Obregon-Henao G; Ahveninen J; Khan S; Babadi B; Iglesias JE; Hämäläinen MS; Purdon PL
    Proc Natl Acad Sci U S A; 2017 Nov; 114(48):E10465-E10474. PubMed ID: 29138310
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Variation-based sparse cortical current density imaging in estimating cortical sources with MEG data.
    Ding L; Zhu M; Zhang W; Dickens DL
    Annu Int Conf IEEE Eng Med Biol Soc; 2010; 2010():5145-8. PubMed ID: 21095813
    [TBL] [Abstract][Full Text] [Related]  

  • 13. fMRI-EEG integrated cortical source imaging by use of time-variant spatial constraints.
    Liu Z; He B
    Neuroimage; 2008 Feb; 39(3):1198-214. PubMed ID: 18036833
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Beamformer source analysis and connectivity on concurrent EEG and MEG data during voluntary movements.
    Muthuraman M; Hellriegel H; Hoogenboom N; Anwar AR; Mideksa KG; Krause H; Schnitzler A; Deuschl G; Raethjen J
    PLoS One; 2014; 9(3):e91441. PubMed ID: 24618596
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Reconstructing spatially extended brain sources via enforcing multiple transform sparseness.
    Zhu M; Zhang W; Dickens DL; Ding L
    Neuroimage; 2014 Feb; 86():280-93. PubMed ID: 24103850
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Brainstorm: a user-friendly application for MEG/EEG analysis.
    Tadel F; Baillet S; Mosher JC; Pantazis D; Leahy RM
    Comput Intell Neurosci; 2011; 2011():879716. PubMed ID: 21584256
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Differences between MEG and high-density EEG source localizations using a distributed source model in comparison to fMRI.
    Klamer S; Elshahabi A; Lerche H; Braun C; Erb M; Scheffler K; Focke NK
    Brain Topogr; 2015 Jan; 28(1):87-94. PubMed ID: 25296614
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Sparse imaging of cortical electrical current densities via wavelet transforms.
    Liao K; Zhu M; Ding L; Valette S; Zhang W; Dickens D
    Phys Med Biol; 2012 Nov; 57(21):6881-901. PubMed ID: 23038163
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Reconstruction of extended cortical sources for EEG and MEG based on a Monte-Carlo-Markov-chain estimator.
    Kincses WE; Braun C; Kaiser S; Grodd W; Ackermann H; Mathiak K
    Hum Brain Mapp; 2003 Feb; 18(2):100-10. PubMed ID: 12518290
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Mapping the signal-to-noise-ratios of cortical sources in magnetoencephalography and electroencephalography.
    Goldenholz DM; Ahlfors SP; Hämäläinen MS; Sharon D; Ishitobi M; Vaina LM; Stufflebeam SM
    Hum Brain Mapp; 2009 Apr; 30(4):1077-86. PubMed ID: 18465745
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 24.