These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

272 related articles for article (PubMed ID: 22102635)

  • 1. Effective ventilation at conventional rates with tidal volume below instrumental dead space: a bench study.
    Keszler M; Montaner MB; Abubakar K
    Arch Dis Child Fetal Neonatal Ed; 2012 May; 97(3):F188-92. PubMed ID: 22102635
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The impact of instrumental dead-space in volume-targeted ventilation of the extremely low birth weight (ELBW) infant.
    Nassabeh-Montazami S; Abubakar KM; Keszler M
    Pediatr Pulmonol; 2009 Feb; 44(2):128-33. PubMed ID: 19061234
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Effect of inspiratory flow rate on the efficiency of carbon dioxide removal at tidal volumes below instrumental dead space.
    Hurley EH; Keszler M
    Arch Dis Child Fetal Neonatal Ed; 2017 Mar; 102(2):F126-F130. PubMed ID: 27515984
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Reduction of Endotracheal Tube Connector Dead Space Improves Ventilation: A Bench Test on a Model Lung Simulating an Extremely Low Birth Weight Neonate.
    Ivanov VA
    Respir Care; 2016 Feb; 61(2):155-61. PubMed ID: 26577200
    [TBL] [Abstract][Full Text] [Related]  

  • 5. The effect of increased apparatus dead space and tidal volumes on carbon dioxide elimination and oxygen saturations in a low-flow anesthesia system.
    Enekvist BJ; Luttropp HH; Johansson A
    J Clin Anesth; 2008 May; 20(3):170-4. PubMed ID: 18502358
    [TBL] [Abstract][Full Text] [Related]  

  • 6. The effects of passive humidifier dead space on respiratory variables in paralyzed and spontaneously breathing patients.
    Campbell RS; Davis K; Johannigman JA; Branson RD
    Respir Care; 2000 Mar; 45(3):306-12. PubMed ID: 10771799
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Elimination of ventilator dead space during synchronized ventilation in premature infants.
    Claure N; D'Ugard C; Bancalari E
    J Pediatr; 2003 Sep; 143(3):315-20. PubMed ID: 14517512
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Instrumental dead space: A glass ceiling for extremely low birth weight preterm infants? A dead space washout bench study.
    Danan C; Tauzin M; Jung C; Carbonnier B; Dassieu G; Decobert F; Caeymaex L
    Pediatr Pulmonol; 2023 May; 58(5):1514-1519. PubMed ID: 36785523
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Predicting dead space ventilation in critically ill patients using clinically available data.
    Frankenfield DC; Alam S; Bekteshi E; Vender RL
    Crit Care Med; 2010 Jan; 38(1):288-91. PubMed ID: 19789453
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Volume targeted ventilation (volume guarantee) in the weaning phase of premature newborn infants.
    Scopesi F; Calevo MG; Rolfe P; Arioni C; Traggiai C; Risso FM; Serra G
    Pediatr Pulmonol; 2007 Oct; 42(10):864-70. PubMed ID: 17726708
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Aspiration of airway dead space. A new method to enhance CO2 elimination.
    De Robertis E; Sigurdsson SE; Drefeldt B; Jonson B
    Am J Respir Crit Care Med; 1999 Mar; 159(3):728-32. PubMed ID: 10051243
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Time and volume dependence of dead space in healthy and surfactant-depleted rat lungs during spontaneous breathing and mechanical ventilation.
    Dassow C; Schwenninger D; Runck H; Guttmann J
    J Appl Physiol (1985); 2013 Nov; 115(9):1268-74. PubMed ID: 23950167
    [TBL] [Abstract][Full Text] [Related]  

  • 13. End-tidal CO2 as a function of tidal volume in mechanically ventilated infants.
    Greer KJ; Bowen WA; Krauss AN
    Am J Perinatol; 2003 Nov; 20(8):447-51. PubMed ID: 14703593
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A novel method of distal end-tidal CO2 capnography in intubated infants: comparison with arterial CO2 and with proximal mainstream end-tidal CO2.
    Kugelman A; Zeiger-Aginsky D; Bader D; Shoris I; Riskin A
    Pediatrics; 2008 Dec; 122(6):e1219-24. PubMed ID: 19029196
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Monitoring Dead Space in Mechanically Ventilated Children: Volumetric Capnography Versus Time-Based Capnography.
    Bhalla AK; Rubin S; Newth CJ; Ross P; Morzov R; Soto-Campos G; Khemani R
    Respir Care; 2015 Nov; 60(11):1548-55. PubMed ID: 26199451
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Albuterol delivery from a metered-dose inhaler with spacer is reduced following short-duration manual ventilation in a neonatal ventilator-lung model.
    Lugo RA; Ballard J
    Respir Care; 2004 Sep; 49(9):1029-34. PubMed ID: 15329174
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Lung mechanics and gas exchange during pressure-control ventilation in dogs. Augmentation of CO2 elimination by an intratracheal catheter.
    Nahum A; Burke WC; Ravenscraft SA; Marcy TW; Adams AB; Crooke PS; Marini JJ
    Am Rev Respir Dis; 1992 Oct; 146(4):965-73. PubMed ID: 1416426
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [Simultaneous measurements of end-expiratory and transcutaneous carbon dioxide partial pressure in ventilated premature and newborn infants].
    Arsowa S; Schmalisch G; Wauer RR
    Klin Padiatr; 1997; 209(2):47-53. PubMed ID: 9198671
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Sidestream microstream end tidal carbon dioxide measurements and blood gas correlations in neonatal intensive care unit.
    Singh BS; Gilbert U; Singh S; Govindaswami B
    Pediatr Pulmonol; 2013 Mar; 48(3):250-6. PubMed ID: 22589000
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Effects of instrumental dead space reduction during weaning from synchronized ventilation in preterm infants.
    Estay A; Claure N; D'Ugard C; Organero R; Bancalari E
    J Perinatol; 2010 Jul; 30(7):479-83. PubMed ID: 20010615
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 14.