BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

137 related articles for article (PubMed ID: 22109245)

  • 1. Comparison of real-time three-dimensional echocardiography with cardiovascular magnetic resonance for left ventricular volumetric assessment in unselected patients.
    Miller CA; Pearce K; Jordan P; Argyle R; Clark D; Stout M; Ray SG; Schmitt M
    Eur Heart J Cardiovasc Imaging; 2012 Feb; 13(2):187-95. PubMed ID: 22109245
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Quantitative Assessment of Right Ventricular Volumes and Ejection Fraction in Patients with Left Ventricular Systolic Dysfunction by Real Time Three-Dimensional Echocardiography versus Cardiac Magnetic Resonance Imaging.
    Kim J; Cohen SB; Atalay MK; Maslow AD; Poppas A
    Echocardiography; 2015 May; 32(5):805-12. PubMed ID: 25109323
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Three-dimensional echocardiography in various types of heart disease: a comparison study of magnetic resonance imaging and 64-slice computed tomography in a real-world population.
    Squeri A; Censi S; Reverberi C; Gaibazzi N; Baldelli M; Binno SM; Properzi E; Bosi S
    J Echocardiogr; 2017 Mar; 15(1):18-26. PubMed ID: 27589871
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Quantification of left ventricular size and function using contrast-enhanced real-time 3D imaging with power modulation: comparison with cardiac MRI.
    Coon PD; Pollard H; Furlong K; Lang RM; Mor-Avi V
    Ultrasound Med Biol; 2012 Nov; 38(11):1853-8. PubMed ID: 22906750
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Real-time 3-dimensional echocardiographic quantification of left ventricular volumes: multicenter study for validation with magnetic resonance imaging and investigation of sources of error.
    Mor-Avi V; Jenkins C; Kühl HP; Nesser HJ; Marwick T; Franke A; Ebner C; Freed BH; Steringer-Mascherbauer R; Pollard H; Weinert L; Niel J; Sugeng L; Lang RM
    JACC Cardiovasc Imaging; 2008 Jul; 1(4):413-23. PubMed ID: 19356461
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Rapid online quantification of left ventricular volume from real-time three-dimensional echocardiographic data.
    Jacobs LD; Salgo IS; Goonewardena S; Weinert L; Coon P; Bardo D; Gerard O; Allain P; Zamorano JL; de Isla LP; Mor-Avi V; Lang RM
    Eur Heart J; 2006 Feb; 27(4):460-8. PubMed ID: 16319085
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Quantification of left ventricular volumes and function in anesthetized beagles using real-time three-dimensional echocardiography: 4D-TomTec™ analysis versus 4D-AutLVQ™ analysis in comparison with cardiac magnetic resonance imaging.
    Eskofier J; Wefstaedt P; Beyerbach M; Nolte I; Hungerbühler SO
    BMC Vet Res; 2015 Oct; 11():260. PubMed ID: 26459280
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Knowledge-based reconstruction of right ventricular volumes using real-time three-dimensional echocardiographic as well as cardiac magnetic resonance images: comparison with a cardiac magnetic resonance standard.
    Laser KT; Horst JP; Barth P; Kelter-Klöpping A; Haas NA; Burchert W; Kececioglu D; Körperich H
    J Am Soc Echocardiogr; 2014 Oct; 27(10):1087-97. PubMed ID: 24969839
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Right ventricular global longitudinal strain is an independent predictor of right ventricular function: a multimodality study of cardiac magnetic resonance imaging, real time three-dimensional echocardiography and speckle tracking echocardiography.
    Lu KJ; Chen JX; Profitis K; Kearney LG; DeSilva D; Smith G; Ord M; Harberts S; Calafiore P; Jones E; Srivastava PM
    Echocardiography; 2015 Jun; 32(6):966-74. PubMed ID: 25287078
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Single-beat versus multibeat real-time 3D echocardiography for assessing left ventricular volumes and ejection fraction: a comparison study with cardiac magnetic resonance.
    Macron L; Lim P; Bensaid A; Nahum J; Dussault C; Mitchell-Heggs L; Dubois-Randé JL; Deux JF; Gueret P
    Circ Cardiovasc Imaging; 2010 Jul; 3(4):450-5. PubMed ID: 20435854
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Feasibility of single-beat full-volume capture real-time three-dimensional echocardiography and auto-contouring algorithm for quantification of left ventricular volume: validation with cardiac magnetic resonance imaging.
    Chang SA; Lee SC; Kim EY; Hahm SH; Jang SY; Park SJ; Choi JO; Park SW; Choe YH; Oh JK
    J Am Soc Echocardiogr; 2011 Aug; 24(8):853-9. PubMed ID: 21645992
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Quantitative assessment of left ventricular volume and ejection fraction using two-dimensional speckle tracking echocardiography.
    Nishikage T; Nakai H; Mor-Avi V; Lang RM; Salgo IS; Settlemier SH; Husson S; Takeuchi M
    Eur J Echocardiogr; 2009 Jan; 10(1):82-8. PubMed ID: 18490270
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Accuracy and reproducibility of quantitation of left ventricular function by real-time three-dimensional echocardiography versus cardiac magnetic resonance.
    Soliman OI; Kirschbaum SW; van Dalen BM; van der Zwaan HB; Mahdavian Delavary B; Vletter WB; van Geuns RJ; Ten Cate FJ; Geleijnse ML
    Am J Cardiol; 2008 Sep; 102(6):778-83. PubMed ID: 18774006
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Validating real-time three-dimensional echocardiography against cardiac magnetic resonance, for the determination of ventricular mass, volume and ejection fraction: a meta-analysis.
    Dissabandara T; Lin K; Forwood M; Sun J
    Clin Res Cardiol; 2024 Mar; 113(3):367-392. PubMed ID: 37079054
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Clinical value of real-time three-dimensional echocardiography for right ventricular quantification in congenital heart disease: validation with cardiac magnetic resonance imaging.
    van der Zwaan HB; Helbing WA; McGhie JS; Geleijnse ML; Luijnenburg SE; Roos-Hesselink JW; Meijboom FJ
    J Am Soc Echocardiogr; 2010 Feb; 23(2):134-40. PubMed ID: 20152693
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Quantitative assessment of left ventricular size and function: side-by-side comparison of real-time three-dimensional echocardiography and computed tomography with magnetic resonance reference.
    Sugeng L; Mor-Avi V; Weinert L; Niel J; Ebner C; Steringer-Mascherbauer R; Schmidt F; Galuschky C; Schummers G; Lang RM; Nesser HJ
    Circulation; 2006 Aug; 114(7):654-61. PubMed ID: 16894035
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Value of real time three-dimensional echocardiography in patients with hypertrophic cardiomyopathy: comparison with two-dimensional echocardiography and magnetic resonance imaging.
    Bicudo LS; Tsutsui JM; Shiozaki A; Rochitte CE; Arteaga E; Mady C; Ramires JA; Mathias W
    Echocardiography; 2008 Aug; 25(7):717-26. PubMed ID: 18445062
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Evaluation of automated measurement of left ventricular volume by novel real-time 3-dimensional echocardiographic system: Validation with cardiac magnetic resonance imaging and 2-dimensional echocardiography.
    Shibayama K; Watanabe H; Iguchi N; Sasaki S; Mahara K; Umemura J; Sumiyoshi T
    J Cardiol; 2013 Apr; 61(4):281-8. PubMed ID: 23466066
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Reproducibility of right ventricular volumes and ejection fraction using real-time three-dimensional echocardiography: comparison with cardiac MRI.
    Jenkins C; Chan J; Bricknell K; Strudwick M; Marwick TH
    Chest; 2007 Jun; 131(6):1844-51. PubMed ID: 17400663
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Real time three-dimensional echocardiographic assessment of left ventricular function in heart failure patients: underestimation of left ventricular volume increases with the degree of dilatation.
    Moceri P; Doyen D; Bertora D; Cerboni P; Ferrari E; Gibelin P
    Echocardiography; 2012 Sep; 29(8):970-7. PubMed ID: 22563905
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.