447 related articles for article (PubMed ID: 22109957)
1. Transcatheter aortic valve implantation with a self-expanding nitinol bioprosthesis: prediction of the need for permanent pacemaker using simple baseline and procedural characteristics.
Saia F; Lemos PA; Bordoni B; Cervi E; Boriani G; Ciuca C; Taglieri N; Mariani J; Kalil Filho R; Marzocchi A
Catheter Cardiovasc Interv; 2012 Apr; 79(5):712-9. PubMed ID: 22109957
[TBL] [Abstract][Full Text] [Related]
2. Predictors for permanent pacemaker requirement after transcatheter aortic valve implantation with the CoreValve bioprosthesis.
Jilaihawi H; Chin D; Vasa-Nicotera M; Jeilan M; Spyt T; Ng GA; Bence J; Logtens E; Kovac J
Am Heart J; 2009 May; 157(5):860-6. PubMed ID: 19376312
[TBL] [Abstract][Full Text] [Related]
3. Incidence and predictors of permanent pacemaker implantation following transcatheter aortic valve implantation: analysis from the German transcatheter aortic valve interventions registry.
Ledwoch J; Franke J; Gerckens U; Kuck KH; Linke A; Nickenig G; Krülls-Münch J; Vöhringer M; Hambrecht R; Erbel R; Richardt G; Horack M; Zahn R; Senges J; Sievert H;
Catheter Cardiovasc Interv; 2013 Oct; 82(4):E569-77. PubMed ID: 23475694
[TBL] [Abstract][Full Text] [Related]
4. Incidence and predictors of permanent pacemaker requirement after transcatheter aortic valve implantation with a self-expanding bioprosthesis.
Ferreira ND; Caeiro D; Adão L; Oliveira M; Gonçalves H; Ribeiro J; Teixeira M; Albuquerque A; Primo J; Braga P; Simões L; Ribeiro VG
Pacing Clin Electrophysiol; 2010 Nov; 33(11):1364-72. PubMed ID: 20723083
[TBL] [Abstract][Full Text] [Related]
5. Conduction disturbances and permanent cardiac pacing after transcatheter implantation of the CoreValve aortic bioprosthesis: initial single centre experience.
Czerwińska K; Hryniewiecki T; Oręziak A; Dąbrowski M; Michałowska I; Witkowski A; Demkow M; Stępińska J; Orłowska Baranowska E; Rużyłło W
Kardiol Pol; 2012; 70(2):121-8. PubMed ID: 22427074
[TBL] [Abstract][Full Text] [Related]
6. Predictors and clinical outcomes of permanent pacemaker implantation after transcatheter aortic valve replacement: the PARTNER (Placement of AoRtic TraNscathetER Valves) trial and registry.
Nazif TM; Dizon JM; Hahn RT; Xu K; Babaliaros V; Douglas PS; El-Chami MF; Herrmann HC; Mack M; Makkar RR; Miller DC; Pichard A; Tuzcu EM; Szeto WY; Webb JG; Moses JW; Smith CR; Williams MR; Leon MB; Kodali SK;
JACC Cardiovasc Interv; 2015 Jan; 8(1 Pt A):60-9. PubMed ID: 25616819
[TBL] [Abstract][Full Text] [Related]
7. Postoperative permanent pacemaker implantation in patients undergoing trans-catheter aortic valve implantation: what is the incidence and are there any predicting factors?
Bates MG; Matthews IG; Fazal IA; Turley AJ
Interact Cardiovasc Thorac Surg; 2011 Feb; 12(2):243-53. PubMed ID: 21098508
[TBL] [Abstract][Full Text] [Related]
8. Transapical transcatheter aortic valve implantation using the JenaValve™ system: acute and 30-day results of the multicentre CE-mark study.
Treede H; Mohr FW; Baldus S; Rastan A; Ensminger S; Arnold M; Kempfert J; Figulla HR
Eur J Cardiothorac Surg; 2012 Jun; 41(6):e131-8. PubMed ID: 22508111
[TBL] [Abstract][Full Text] [Related]
9. Patients without prolonged QRS after TAVI with CoreValve device do not experience high-degree atrio-ventricular block.
Mouillet G; Lellouche N; Lim P; Meguro K; Yamamoto M; Deux JF; Monin JL; Bergoënd E; Dubois-Randé JL; Teiger E
Catheter Cardiovasc Interv; 2013 Apr; 81(5):882-7. PubMed ID: 22972678
[TBL] [Abstract][Full Text] [Related]
10. Transcatheter valve-in-valve implantation using Corevalve Revalving System for failed surgical aortic bioprostheses.
Bedogni F; Laudisa ML; Pizzocri S; Tamburino C; Ussia GP; Petronio AS; Napodano M; Ramondo A; Presbitero P; Ettori F; Santoro G; Klugman S; De Marco F; Brambilla N; Testa L
JACC Cardiovasc Interv; 2011 Nov; 4(11):1228-34. PubMed ID: 22115664
[TBL] [Abstract][Full Text] [Related]
11. Risk Factors for Permanent Pacemaker after Implantation of Surgical or Percutaneous Self-Expanding Aortic Prostheses.
Villa E; Clerici A; Messina A; Testa L; Bedogni F; Moneta A; Donatelli F; Troise G
J Heart Valve Dis; 2016 Nov; 25(6):663-671. PubMed ID: 28290164
[TBL] [Abstract][Full Text] [Related]
12. Predictors of right ventricular pacing and pacemaker dependence in transcatheter aortic valve replacement patients.
Sharma E; Chu AF
J Interv Card Electrophysiol; 2018 Jan; 51(1):77-86. PubMed ID: 29260369
[TBL] [Abstract][Full Text] [Related]
13. Inverse Relationship Between Membranous Septal Length and the Risk of Atrioventricular Block in Patients Undergoing Transcatheter Aortic Valve Implantation.
Hamdan A; Guetta V; Klempfner R; Konen E; Raanani E; Glikson M; Goitein O; Segev A; Barbash I; Fefer P; Spiegelstein D; Goldenberg I; Schwammenthal E
JACC Cardiovasc Interv; 2015 Aug; 8(9):1218-1228. PubMed ID: 26292585
[TBL] [Abstract][Full Text] [Related]
14. Echocardiographic outcomes of self-expandable CoreValve versus balloon-expandable Edwards SAPIEN XT valves: the comparison of two bioprosthesis implanted in a single centre.
Kaya D; Tanriverdi Z; Dursun H; Colluoglu T
Int J Cardiovasc Imaging; 2016 Sep; 32(9):1371-1378. PubMed ID: 27278270
[TBL] [Abstract][Full Text] [Related]
15. Sutureless replacement versus transcatheter valve implantation in aortic valve stenosis: a propensity-matched analysis of 2 strategies in high-risk patients.
Santarpino G; Pfeiffer S; Jessl J; Dell'Aquila AM; Pollari F; Pauschinger M; Fischlein T
J Thorac Cardiovasc Surg; 2014 Feb; 147(2):561-7. PubMed ID: 24280712
[TBL] [Abstract][Full Text] [Related]
16. Optimal Implantation Depth and Adherence to Guidelines on Permanent Pacing to Improve the Results of Transcatheter Aortic Valve Replacement With the Medtronic CoreValve System: The CoreValve Prospective, International, Post-Market ADVANCE-II Study.
Petronio AS; Sinning JM; Van Mieghem N; Zucchelli G; Nickenig G; Bekeredjian R; Bosmans J; Bedogni F; Branny M; Stangl K; Kovac J; Schiltgen M; Kraus S; de Jaegere P
JACC Cardiovasc Interv; 2015 May; 8(6):837-846. PubMed ID: 25999108
[TBL] [Abstract][Full Text] [Related]
17. Transcatheter aortic valve replacement using a self-expanding bioprosthesis in patients with severe aortic stenosis at extreme risk for surgery.
Popma JJ; Adams DH; Reardon MJ; Yakubov SJ; Kleiman NS; Heimansohn D; Hermiller J; Hughes GC; Harrison JK; Coselli J; Diez J; Kafi A; Schreiber T; Gleason TG; Conte J; Buchbinder M; Deeb GM; Carabello B; Serruys PW; Chenoweth S; Oh JK;
J Am Coll Cardiol; 2014 May; 63(19):1972-81. PubMed ID: 24657695
[TBL] [Abstract][Full Text] [Related]
18. Effect of severe left ventricular systolic dysfunction on hospital outcome after transcatheter aortic valve implantation or surgical aortic valve replacement: results from a propensity-matched population of the Italian OBSERVANT multicenter study.
Onorati F; D'Errigo P; Grossi C; Barbanti M; Ranucci M; Covello DR; Rosato S; Maraschini A; Santoro G; Tamburino C; Seccareccia F; Santini F; Menicanti L;
J Thorac Cardiovasc Surg; 2014 Feb; 147(2):568-75. PubMed ID: 24263007
[TBL] [Abstract][Full Text] [Related]
19. Clinical outcome following Transcatheter Aortic Valve Implantation in patients with impaired left ventricular systolic function.
van der Boon RM; Nuis RJ; Van Mieghem NM; Benitez LM; van Geuns RJ; Galema TW; van Domburg RT; Geleijnse ML; Dager A; de Jaegere PP
Catheter Cardiovasc Interv; 2012 Apr; 79(5):702-10. PubMed ID: 22121094
[TBL] [Abstract][Full Text] [Related]
20. Sutureless aortic valve replacement with Perceval bioprosthesis: are there predicting factors for postoperative pacemaker implantation?
Vogt F; Pfeiffer S; Dell'Aquila AM; Fischlein T; Santarpino G
Interact Cardiovasc Thorac Surg; 2016 Mar; 22(3):253-8. PubMed ID: 26614526
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]