These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

148 related articles for article (PubMed ID: 22110014)

  • 21. The use of a guide catheter extension system as an aid during transradial percutaneous coronary intervention of coronary artery bypass grafts.
    Farooq V; Mamas MA; Fath-Ordoubadi F; Fraser DG
    Catheter Cardiovasc Interv; 2011 Nov; 78(6):847-63. PubMed ID: 21234926
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Balloon-assisted tracking of a guide catheter through difficult radial anatomy: a technical report.
    Patel T; Shah S; Pancholy S
    Catheter Cardiovasc Interv; 2013 Apr; 81(5):E215-8. PubMed ID: 22639459
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Percutaneous coronary intervention under the rigid restriction of contrast media dose in patients with chronic renal insufficiency.
    Yamamoto E; Takano H; Takayama M
    J Invasive Cardiol; 2006 Jun; 18(6):E169-72. PubMed ID: 16775894
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Anchor-balloon technique to facilitate stent delivery via the GuideLiner catheter in percutaneous coronary intervention.
    Ali M; Yagoub H; Ibrahim A; Ahmed M; Ibrahim M; Saunders J; Brennan A; Cahill D; Hennessy T; Hynes BG; Arnous S; Kiernan TJ
    Future Cardiol; 2018 Jul; 14(4):291-299. PubMed ID: 29927308
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Challenges associated with use of the GuideLiner catheter in percutaneous coronary interventions.
    Papayannis AC; Michael TT; Brilakis ES
    J Invasive Cardiol; 2012 Jul; 24(7):370-1. PubMed ID: 22781481
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Magnetic positioning system in coronary angiography and percutaneous intervention: a feasibility and safety study.
    Weisz G; Smilowitz NR; Moses JW; Rabbani LE; Collins MB; Herscovici A; Jeron A; Leon MB; Luchner A
    Catheter Cardiovasc Interv; 2013 Dec; 82(7):1084-90. PubMed ID: 23592312
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Impact of diabetes and acute coronary syndrome on survival in patients treated with drug-eluting stents.
    Lee MS; Jurewitz D; Zimmer R; Pessegueiro A; Bhatia R; Currier J; Yeatman L; Tobis JM
    Catheter Cardiovasc Interv; 2008 Dec; 72(7):909-14. PubMed ID: 19016467
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Intracoronary guidewire emboli: a unique complication and retrieval of the wire.
    Demircan S; Yazici M; Durna K; Yasar E
    Cardiovasc Revasc Med; 2008; 9(4):278-80. PubMed ID: 18928955
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Efficacy of mother-child-grandchild technique: 4F and 5F inner catheters through mother guide catheter.
    Ashikaga T; Yoshikawa S; Kurihara K; Isobe M
    Cardiovasc Revasc Med; 2014 Jun; 15(4):244-7. PubMed ID: 24560298
    [TBL] [Abstract][Full Text] [Related]  

  • 30. A unique complication with use of the GuideLiner catheter in percutaneous coronary interventions and its successful management.
    Bhat T; Baydoun H; Tamburino F
    J Invasive Cardiol; 2014 Apr; 26(4):E42-4. PubMed ID: 24717280
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Novel use of a guide extension mother-and-child catheter for adjunctive thrombectomy during percutaneous coronary intervention for acute coronary syndromes.
    Mani AJ
    J Invasive Cardiol; 2014 Jun; 26(6):249-54. PubMed ID: 24907080
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Percutaneous coronary intervention using a virtual 3-Fr guiding catheter.
    Mizuno S; Takeshita S; Taketani Y; Saito S
    Catheter Cardiovasc Interv; 2010 Jun; 75(7):983-8. PubMed ID: 20146327
    [TBL] [Abstract][Full Text] [Related]  

  • 33. A new technique for coronary guide catheter exchange over coronary guidewire using GuideLiner catheter.
    Stys TP; Khan MA; Rajpurohit N; Stys AT
    J Invasive Cardiol; 2014 May; 26(5):E56-8. PubMed ID: 24791727
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Utility of the guideliner catheter for percutaneous coronary interventions in patients with prior transcatheter aortic valve replacement.
    Bharadwaj AS; Bhatheja S; Sharma SK; Kini AS
    Catheter Cardiovasc Interv; 2018 Feb; 91(2):271-276. PubMed ID: 28795527
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Supported percutaneous coronary intervention using a novel 6-Fr intra-aortic balloon pump catheter via the brachial artery in a nonagenarian patient with an abdominal aortic aneurysm.
    Takahashi A; Taniguchi N
    Catheter Cardiovasc Interv; 2011 Jun; 77(7):1045-8. PubMed ID: 21413123
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Unintended stent removal during fractured-guidewire removal in emergency angioplasty.
    Gagnor A; Tomassini F; Infantino V; Varbella F
    J Cardiovasc Med (Hagerstown); 2009 Nov; 10(11):885-6. PubMed ID: 19644386
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Transradial interventions with the GuideLiner catheter: role of proximal vessel angulation.
    Eddin MJ; Armstrong EJ; Javed U; Rogers JH
    Cardiovasc Revasc Med; 2013; 14(5):275-9. PubMed ID: 23972538
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Extended use of the GuideLiner in complex coronary interventions.
    Chan PH; Alegria-Barrero E; Foin N; Paulo M; Lindsay AC; Viceconte N; Di Mario C
    EuroIntervention; 2015 Jul; 11(3):325-35. PubMed ID: 24930135
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Coronary intervention with 4-French catheters.
    Takeshita S; Tanaka S; Saito S
    Catheter Cardiovasc Interv; 2010 Apr; 75(5):735-9. PubMed ID: 20049960
    [TBL] [Abstract][Full Text] [Related]  

  • 40. A case of effective reduction in the amount of contrast medium using selective coronary angiography with a thrombus aspiration catheter.
    Shinozaki N
    J Invasive Cardiol; 2011 Oct; 23(10):E232-4. PubMed ID: 21972167
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 8.