These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

403 related articles for article (PubMed ID: 22115665)

  • 21. Feasibility, Accuracy, and Reproducibility of Aortic Annular and Root Sizing for Transcatheter Aortic Valve Replacement Using Novel Automated Three-Dimensional Echocardiographic Software: Comparison with Multi-Detector Row Computed Tomography.
    Prihadi EA; van Rosendael PJ; Vollema EM; Bax JJ; Delgado V; Ajmone Marsan N
    J Am Soc Echocardiogr; 2018 Apr; 31(4):505-514.e3. PubMed ID: 29174341
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Automatic 3D aortic annulus sizing by computed tomography in the planning of transcatheter aortic valve implantation.
    Queirós S; Dubois C; Morais P; Adriaenssens T; Fonseca JC; Vilaça JL; D'hooge J
    J Cardiovasc Comput Tomogr; 2017; 11(1):25-32. PubMed ID: 28063844
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Erroneous measurement of the aortic annular diameter using 2-dimensional echocardiography resulting in inappropriate CoreValve size selection: a retrospective comparison with multislice computed tomography.
    Mylotte D; Dorfmeister M; Elhmidi Y; Mazzitelli D; Bleiziffer S; Wagner A; Noterdaeme T; Lange R; Piazza N
    JACC Cardiovasc Interv; 2014 Jun; 7(6):652-61. PubMed ID: 24947721
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Cardiac CT: necessary for precise sizing for transcatheter aortic implantation.
    Schultz CJ; Moelker AD; Tzikas A; Rossi A; van Geuns RJ; de Feyter PJ; Serruys PW
    EuroIntervention; 2010 May; 6 Suppl G():G6-G13. PubMed ID: 20542831
    [TBL] [Abstract][Full Text] [Related]  

  • 25. A novel contribution towards coherent and reproducible intravalvular measurement of the aortic annulus by multidetector computed tomography ahead of transcatheter aortic valve implantation.
    Dementhon J; Rioufol G; Obadia JF; Vergnat M; Green L; Croisille P; Boussel L; Peron J; Revel D; Finet G
    Arch Cardiovasc Dis; 2015 May; 108(5):281-92. PubMed ID: 25863427
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Prosthesis sizing for transcatheter aortic valve implantation--comparison of three dimensional transesophageal echocardiography with multislice computed tomography.
    Husser O; Holzamer A; Resch M; Endemann DH; Nunez J; Bodi V; Schmid C; Riegger GA; Gössmann H; Hamer O; Stroszczynski C; Luchner A; Hilker M; Hengstenberg C
    Int J Cardiol; 2013 Oct; 168(4):3431-8. PubMed ID: 23688431
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Aortic annulus area assessment by multidetector computed tomography for predicting paravalvular regurgitation in patients undergoing balloon-expandable transcatheter aortic valve implantation: a comparison with transthoracic and transesophageal echocardiography.
    Pontone G; Andreini D; Bartorelli AL; Bertella E; Cortinovis S; Mushtaq S; Annoni A; Formenti A; Baggiano A; Conte E; Tamborini G; Muratori M; Gripari P; Bovis F; Veglia F; Foti C; Alamanni F; Ballerini G; Fiorentini C; Pepi M
    Am Heart J; 2012 Oct; 164(4):576-84. PubMed ID: 23067917
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Multi-detector computed tomography is equivalent to trans-oesophageal echocardiography for the assessment of the aortic annulus before transcatheter aortic valve implantation.
    Rixe J; Schuhbaeck A; Liebetrau C; Moellmann H; Nef HM; Szardien S; Brandt R; Schmitt J; Neumann T; Schneider C; Krombach G; Hamm CW; Achenbach S; Rolf A
    Eur Radiol; 2012 Dec; 22(12):2662-9. PubMed ID: 22688129
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Effective diameter of the aortic annulus prior to transcatheter aortic valve implantation: influence of area-based versus perimeter-based calculation.
    von Aspern K; Foldyna B; Etz CD; Hoyer A; Girrbach F; Holzhey D; Lücke C; Grothoff M; Linke A; Mohr FW; Gutberlet M; Lehmkuhl L
    Int J Cardiovasc Imaging; 2015 Jan; 31(1):163-9. PubMed ID: 25165022
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Assessment of aortic annulus dimensions for Edwards SAPIEN Transapical Heart Valve implantation by computed tomography: calculating average diameter using a virtual ring method.
    Blanke P; Siepe M; Reinöhl J; Zehender M; Beyersdorf F; Schlensak C; Langer M; Pache G
    Eur J Cardiothorac Surg; 2010 Dec; 38(6):750-8. PubMed ID: 20472458
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Aortic annulus evaluation in transcatheter aortic valve implantation.
    Hutter A; Opitz A; Bleiziffer S; Ruge H; Hettich I; Mazzitelli D; Will A; Tassani P; Bauernschmitt R; Lange R
    Catheter Cardiovasc Interv; 2010 Dec; 76(7):1009-19. PubMed ID: 20518012
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Feasibility and accuracy of 3DTEE versus CT for the evaluation of aortic valve annulus to left main ostium distance before transcatheter aortic valve implantation.
    Tamborini G; Fusini L; Gripari P; Muratori M; Cefalù C; Maffessanti F; Alamanni F; Bartorelli A; Pontone G; Andreini D; Bertella E; Fiorentini C; Pepi M
    JACC Cardiovasc Imaging; 2012 Jun; 5(6):579-88. PubMed ID: 22698526
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Automated 3D analysis of pre-procedural MDCT to predict annulus plane angulation and C-arm positioning: benefit on procedural outcome in patients referred for TAVR.
    Samim M; Stella PR; Agostoni P; Kluin J; Ramjankhan F; Budde RP; Sieswerda G; Algeri E; van Belle C; Elkalioubie A; Juthier F; Belkacemi A; Bertrand ME; Doevendans PA; Van Belle E
    JACC Cardiovasc Imaging; 2013 Feb; 6(2):238-48. PubMed ID: 23489538
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Can balloon aortic valvuloplasty help determine appropriate transcatheter aortic valve size?
    Babaliaros VC; Liff D; Chen EP; Rogers JH; Brown RA; Thourani VH; Guyton RA; Lerakis S; Stillman AE; Raggi P; Cheesborough JE; Veledar E; Green JT; Block PC
    JACC Cardiovasc Interv; 2008 Oct; 1(5):580-6. PubMed ID: 19463362
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Assessment of the aortic annulus by multislice computed tomography, contrast aortography, and trans-thoracic echocardiography in patients referred for transcatheter aortic valve implantation.
    Tzikas A; Schultz CJ; Piazza N; Moelker A; Van Mieghem NM; Nuis RJ; van Geuns RJ; Geleijnse ML; Serruys PW; de Jaegere PP
    Catheter Cardiovasc Interv; 2011 May; 77(6):868-75. PubMed ID: 20824762
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Non-contrast-enhanced magnetic resonance angiography is equal to contrast-enhanced multislice computed tomography for correct aortic sizing before transcatheter aortic valve implantation.
    Bernhardt P; Rodewald C; Seeger J; Gonska B; Buckert D; Radermacher M; Hombach V; Rottbauer W; Wöhrle J
    Clin Res Cardiol; 2016 Mar; 105(3):273-8. PubMed ID: 26395021
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Dynamic characterization of aortic annulus geometry and morphology with multimodality imaging: predictive value for aortic regurgitation after transcatheter aortic valve replacement.
    Masri A; Schoenhagen P; Svensson L; Kapadia SR; Griffin BP; Tuzcu EM; Desai MY
    J Thorac Cardiovasc Surg; 2014 Jun; 147(6):1847-54. PubMed ID: 23870156
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Cross-sectional computed tomographic assessment improves accuracy of aortic annular sizing for transcatheter aortic valve replacement and reduces the incidence of paravalvular aortic regurgitation.
    Jilaihawi H; Kashif M; Fontana G; Furugen A; Shiota T; Friede G; Makhija R; Doctor N; Leon MB; Makkar RR
    J Am Coll Cardiol; 2012 Apr; 59(14):1275-86. PubMed ID: 22365424
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Use of balloon aortic valvuloplasty to size the aortic annulus before implantation of a balloon-expandable transcatheter heart valve.
    Babaliaros VC; Junagadhwalla Z; Lerakis S; Thourani V; Liff D; Chen E; Vassiliades T; Chappell C; Gross N; Patel A; Howell S; Green JT; Veledar E; Guyton R; Block PC
    JACC Cardiovasc Interv; 2010 Jan; 3(1):114-8. PubMed ID: 20129579
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Assessment of the geometric interaction between the Lotus transcatheter aortic valve prosthesis and the native ventricular aortic interface by 320-multidetector computed tomography.
    Gooley RP; Cameron JD; Meredith IT
    JACC Cardiovasc Interv; 2015 Apr; 8(5):740-9. PubMed ID: 25946448
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 21.