These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

81 related articles for article (PubMed ID: 22128208)

  • 1. Implantation of an azygous vein coil to facilitate defibrillation.
    Dayer MJ; Allen J; Jeavons C
    Heart; 2012 Mar; 98(6):519. PubMed ID: 22128208
    [No Abstract]   [Full Text] [Related]  

  • 2. The azygos defibrillator lead for elevated defibrillation thresholds: implant technique, lead stability, and patient series.
    Cooper JA; Latacha MP; Soto GE; Garmany RG; Gleva MJ; Chen J; Faddis MN; Smith TW
    Pacing Clin Electrophysiol; 2008 Nov; 31(11):1405-10. PubMed ID: 18950297
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Novel use of a vascular plug to anchor an azygous vein ICD lead.
    Bar-Cohen Y; Takao CM; Wells WJ; Saxon LA; Cesario DA; Silka MJ
    J Cardiovasc Electrophysiol; 2010 Jan; 21(1):99-102. PubMed ID: 19549034
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Azygous vein coil lowers defibrillation threshold in patients with high defibrillation threshold.
    Seow SC; Tolentino CS; Zhao J; Lim TW
    Europace; 2011 Jun; 13(6):825-8. PubMed ID: 21436136
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Permanent pacemaker lead implantation via azygous vein in a patient with silent superior vena cava syndrome.
    Goktekin O; Besoglu Y; Dogan SM; Birdane A; Unalir A; Gorenek B; Kudaiberdieva G; Cavusoglu Y; Ata N; Aslan R; Timuralp B
    Int J Cardiol; 2007 Apr; 117(1):e4-6. PubMed ID: 17250910
    [TBL] [Abstract][Full Text] [Related]  

  • 6. How to implant a defibrillation coil in the azygous vein.
    Cooper JA; Smith TW
    Heart Rhythm; 2009 Nov; 6(11):1677-80. PubMed ID: 19879550
    [No Abstract]   [Full Text] [Related]  

  • 7. Azygos vein lead implantation: a novel adjunctive technique for implantable cardioverter defibrillator placement.
    Cesario D; Bhargava M; Valderrábano M; Fonarow GC; Wilkoff B; Shivkumar K
    J Cardiovasc Electrophysiol; 2004 Jul; 15(7):780-3. PubMed ID: 15250862
    [TBL] [Abstract][Full Text] [Related]  

  • 8. New transvenous implantable cardioverter defibrillator configuration for use after tricuspid valve surgery.
    Lopez JA
    Europace; 2008 Jun; 10(6):736-7. PubMed ID: 18424456
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Percutaneous permanent pacemaker implantation via the azygous vein in a patient with superior vena cava occlusion.
    Kamdar RH; Schilling RJ
    Pacing Clin Electrophysiol; 2008 Mar; 31(3):386-8. PubMed ID: 18307638
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Novel approach to obtaining vascular access in patients with abandoned endocardial pacemaker and ICD leads.
    Cheng A; Brinker JA; Reeves RC; Henrikson CA
    J Cardiovasc Electrophysiol; 2007 Mar; 18(3):339-41. PubMed ID: 17241373
    [No Abstract]   [Full Text] [Related]  

  • 11. An original defibrillation lead implantation to avoid tricuspid prosthesis damage.
    Grimard C; May MA; Mabo P; Babuty D
    Europace; 2010 Apr; 12(4):589-90. PubMed ID: 20022878
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Defibrillation testing at ICD implantation: are we asking the wrong question?
    Gold MR; Kroll MW; Ellenbogen KA
    Pacing Clin Electrophysiol; 2009 May; 32(5):567-9. PubMed ID: 19422575
    [No Abstract]   [Full Text] [Related]  

  • 13. A novel approach to transvenous dual-chamber pacing lead placement and cardiac defibrillator implantation after tricuspid valve replacement.
    Lopez JA; Lufschanowski R
    J Cardiovasc Electrophysiol; 2008 Aug; 19(8):873-5. PubMed ID: 18179526
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Extraction of embolized lead tip from azygous vein using distal embolic protection device.
    Stuart Mendenhall G; Saba S
    Europace; 2010 Oct; 12(10):1501-2. PubMed ID: 20584739
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Use of an apical suctioning device for placement of a posterior epicardial defibrillator patch: a case report.
    Mitropoulos FA; Odim J; Laks H
    Heart Surg Forum; 2006; 9(3):E641-2. PubMed ID: 16687347
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Cost-effectiveness of the X-STOP® interspinous spacer for lumbar spinal stenosis.
    Skidmore G; Ackerman SJ; Bergin C; Ross D; Butler J; Suthar M; Rittenberg J
    Spine (Phila Pa 1976); 2011 Mar; 36(5):E345-56. PubMed ID: 21270713
    [No Abstract]   [Full Text] [Related]  

  • 17. Utility of intracardiac echocardiography to facilitate transvenous coronary sinus lead placement for biventricular cardioverter-defibrillator implantation.
    Cohen TJ; Juang G
    J Invasive Cardiol; 2003 Nov; 15(11):685-6. PubMed ID: 14608147
    [No Abstract]   [Full Text] [Related]  

  • 18. Achieving low defibrillation thresholds at implant: pharmacological influences, RV coil polarity and position, SVC coil usage and positioning, pulse width settings, and the azygous vein.
    Kroll MW; Schwab JO
    Fundam Clin Pharmacol; 2010 Oct; 24(5):561-73. PubMed ID: 20608994
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Right ventricular outflow tract implantation of an active fixation defibrillation lead through a persistent left superior vena cava.
    Siliste C; Vinereanu D; Margulescu AD; Cinteza M
    Europace; 2008 Dec; 10(12):1454-5. PubMed ID: 18948364
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Use of percutaneous angioplasty to facilitate implantation of the left ventricular pacemaker lead for CRT.
    Fox DJ; Lee HS; Eisenberger M; Davidson NC
    Heart; 2008 Feb; 94(2):158. PubMed ID: 18195122
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 5.