152 related articles for article (PubMed ID: 22128799)
21. Highly Selective Potentiometric Sensing of Biologically Relevant Pyrophosphate and Lysophosphatidic Acid Using
Li L; Tang J; Liu H; Qian Y
Anal Chem; 2022 Nov; 94(43):14854-14860. PubMed ID: 36260062
[TBL] [Abstract][Full Text] [Related]
22. Polymeric membrane electrodes for monohydrogen phosphate and sulfate.
Fibbioli M; Berger M; Schmidtchen FP; Pretsch E
Anal Chem; 2000 Jan; 72(1):156-60. PubMed ID: 10655648
[TBL] [Abstract][Full Text] [Related]
23. Plasticizer-free polymer containing a covalently immobilized Ca2+-selective ionophore for potentiometric and optical sensors.
Qin Y; Peper S; Radu A; Ceresa A; Bakker E
Anal Chem; 2003 Jul; 75(13):3038-45. PubMed ID: 12964748
[TBL] [Abstract][Full Text] [Related]
24. Fluoride-selective polymeric membrane electrodes based on Zr(IV)- and Al(III)-salen ionophores of various structures.
Górski Ł; Matusevich A; Parzuchowski P; Łuciuk I; Malinowska E
Anal Chim Acta; 2010 Apr; 665(1):39-46. PubMed ID: 20381688
[TBL] [Abstract][Full Text] [Related]
25. Improvement of the Upper Detection Limit of Ionophore-Based H
Honig ML; Haba A; O'Leary KMF; Robinson EEA; Madungwe KV; Lin Y; McGuire C; Bühlmann P
Anal Chem; 2024 Jun; 96(24):9901-9908. PubMed ID: 38850234
[TBL] [Abstract][Full Text] [Related]
26. Solid-Contact pH Sensor with Covalent Attachment of Ionophores and Ionic Sites to a Poly(decyl methacrylate) Matrix.
Choi KR; Chen XV; Hu J; Bühlmann P
Anal Chem; 2021 Dec; 93(50):16899-16905. PubMed ID: 34878238
[TBL] [Abstract][Full Text] [Related]
27. Solid-Contact Ion Sensing Without Using an Ion-Selective Membrane through Classic Li-Ion Battery Materials.
Lyu Y; Zhang Y; Xu L; Zhong L; Sun Z; Ma Y; Bao Y; Gan S; Niu L
Anal Chem; 2021 Jun; 93(21):7588-7595. PubMed ID: 34008950
[TBL] [Abstract][Full Text] [Related]
28. Kinetic Description of the Membrane-Solution Interface for Ion-Selective Electrodes.
Hambly B; Guzinski M; Pendley B; Lindner E
ACS Sens; 2020 Jul; 5(7):2146-2154. PubMed ID: 32560587
[TBL] [Abstract][Full Text] [Related]
29. Influence of nonionic surfactants on the potentiometric response of ion-selective polymeric membrane electrodes designed for blood electrolyte measurements.
Malinowska E; Meyerhoff ME
Anal Chem; 1998 Apr; 70(8):1477-88. PubMed ID: 9569759
[TBL] [Abstract][Full Text] [Related]
30. Effects of ion-carrier substituents on the potentiometric-response characteristics in anion-selective membrane electrodes based on iron porphyrins.
Shahrokhian S; Seifi H; Bagherzadeh M; Mousavi SR
Chemphyschem; 2004 May; 5(5):652-60. PubMed ID: 15179717
[TBL] [Abstract][Full Text] [Related]
31. A phase boundary potential model for apparently "twice-nernstian" responses of liquid membrane ion-selective electrodes.
Amemiya S; Bühlmann P; Umezawa Y
Anal Chem; 1998 Feb; 70(3):445-54. PubMed ID: 21644743
[TBL] [Abstract][Full Text] [Related]
32. Fluorous-Phase Ion-Selective pH Electrodes: Electrode Body and Ionophore Optimization for Measurements in the Physiological pH Range.
Chen XV; Mousavi MPS; Bühlmann P
ACS Omega; 2020 Jun; 5(23):13621-13629. PubMed ID: 32566827
[TBL] [Abstract][Full Text] [Related]
33. Polymeric membrane electrodes with improved fluoride selectivity and lifetime based on Zr(IV)- and Al(III)-tetraphenylporphyrin derivatives.
Pietrzak M; Meyerhoff ME; Malinowska E
Anal Chim Acta; 2007 Jul; 596(2):201-9. PubMed ID: 17631098
[TBL] [Abstract][Full Text] [Related]
34. Synthesis and characterization of monoazathiacrown ethers as ionophores for polymeric membrane silver-selective electrodes.
Zhang J; Ding J; Yin T; Hu X; Yu S; Qin W
Talanta; 2010 May; 81(3):1056-62. PubMed ID: 20298893
[TBL] [Abstract][Full Text] [Related]
35. Application of the mixed-potential theory to the interpretation of the potential response of a PVC membrane ion-selective electrode for desipramine.
Osakai T; Imoto M; Sato Y; Sakaki T
Anal Sci; 2012; 28(6):565-70. PubMed ID: 22729041
[TBL] [Abstract][Full Text] [Related]
36. Electroanalytical performance of a terbium(III)-selective sensor based on a neutral ionophore in environmental and medicinal samples.
Gupta VK; Singh AK; Gupta B
Anal Bioanal Chem; 2008 Apr; 390(8):2171-81. PubMed ID: 18335212
[TBL] [Abstract][Full Text] [Related]
37. Calibration-free ionophore-based ion-selective electrodes with a Co(II)/Co(III) redox couple-based solid contact.
Zou XU; Zhen XV; Cheong JH; Bühlmann P
Anal Chem; 2014 Sep; 86(17):8687-92. PubMed ID: 25117517
[TBL] [Abstract][Full Text] [Related]
38. Selective uranyl ion detection by polymeric ion-selective electrodes based on salphenH2 derivatives.
Kim DW; Park KW; Yang MH; Kim TH; Mahajan RK; Kim JS
Talanta; 2007 Nov; 74(2):223-8. PubMed ID: 18371633
[TBL] [Abstract][Full Text] [Related]
39. Development of a pH sensing membrane electrode based on a new calix[4]arene derivative.
Kormalı Ertürün HE; Demirel Özel A; Sayın S; Yılmaz M; Kılıç E
Talanta; 2015 Jan; 132():669-75. PubMed ID: 25476362
[TBL] [Abstract][Full Text] [Related]
40. Selective coulometric release of ions from ion selective polymeric membranes for calibration-free titrations.
Bhakthavatsalam V; Shvarev A; Bakker E
Analyst; 2006 Aug; 131(8):895-900. PubMed ID: 17028722
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]