259 related articles for article (PubMed ID: 22130319)
21. Optical coherence tomography study of healing characteristics of paclitaxel-eluting balloons vs. everolimus-eluting stents for in-stent restenosis: the SEDUCE (Safety and Efficacy of a Drug elUting balloon in Coronary artery rEstenosis) randomised clinical trial.
Adriaenssens T; Dens J; Ughi G; Bennett J; Dubois C; Sinnaeve P; Wiyono S; Coosemans M; Belmans A; D'hooge J; Vrolix M; Desmet W
EuroIntervention; 2014 Aug; 10(4):439-48. PubMed ID: 25138182
[TBL] [Abstract][Full Text] [Related]
22. Very late thrombosis after subintimal sirolimus-eluting stent implantation during percutaneous coronary intervention for chronic total occlusion.
Miyazaki S; Hiasa Y; Kishi K
J Invasive Cardiol; 2010 Aug; 22(8):E162-5. PubMed ID: 20679685
[TBL] [Abstract][Full Text] [Related]
23. Neointimal coverage of zotarolimus-eluting stent at 1, 2, and 3 months' follow-up: an optical coherence tomography study.
Hashikata T; Tojo T; Namba S; Kitasato L; Hashimoto T; Kameda R; Shimohama T; Yamaoka-Tojo M; Ako J
Heart Vessels; 2016 Feb; 31(2):206-11. PubMed ID: 25362579
[TBL] [Abstract][Full Text] [Related]
24. Drug-eluting stent implantation in patients with acute coronary syndrome - the Activity of Platelets after Inhibition and Cardiovascular Events: Optical Coherence Tomography (APICE OCT) study.
Chieffo A; Buchanan GL; Parodi G; Versaci F; Bianchi RM; Valenti R; Saccà S; Mongiardo A; Span S; Migliorini A; Spaccarotella C; Reimers B; Antoniucci D; Indolfi C; Ferrari A; Maehara A; Mintz GS; Colombo A
EuroIntervention; 2014 Dec; 10(8):916-23. PubMed ID: 24974806
[TBL] [Abstract][Full Text] [Related]
25. A prospective randomised study using optical coherence tomography to assess endothelial coverage and neointimal proliferation at 6-months after implantation of a coronary everolimus-eluting stent compared with a bare metal stent postdilated with a paclitaxel-eluting balloon (OCTOPUS Trial): rationale, design and methods.
Poerner TC; Otto S; Gassdorf J; Janiak F; Danzer C; Ferrari M; Figulla HR
EuroIntervention; 2011 May; 7 Suppl K():K93-9. PubMed ID: 22027737
[TBL] [Abstract][Full Text] [Related]
26. Optical coherence tomography evaluation of late strut coverage patterns between first-generation drug-eluting stents and everolimus-eluting stent.
Toledano Delgado FJ; Alvarez-Ossorio MP; de Lezo Cruz-Conde JS; Bellido FM; Romero Moreno MÁ; Fernández-Aceytuno AM; de Lezo Herrerosde Tejada JS; Pineda SO; Saint-Gerons JM; Pavlovic D
Catheter Cardiovasc Interv; 2014 Nov; 84(5):720-6. PubMed ID: 24174291
[TBL] [Abstract][Full Text] [Related]
27. Efficacy of Endeavor zotarolimus-eluting stent implantation for the treatment of very late stent thrombosis with late-acquired incomplete stent apposition after sirolimus-eluting stent implantation.
Kakefuda Y; Sato A; Watabe H; Aihara H; Nishina H; Noguchi Y; Hoshi T; Aonuma K
Heart Vessels; 2016 Jul; 31(7):1196-9. PubMed ID: 26219730
[TBL] [Abstract][Full Text] [Related]
28. First-in-man study evaluating the safety and efficacy of a second generation biodegradable polymer sirolimus-eluting stent in the treatment of patients with de novo coronary lesions: clinical, Angiographic, and OCT outcomes of CREDIT-1.
Wang G; Sun Z; Jin Q; Xu K; Li Y; Wang X; Ma Y; Liu H; Zhao X; Wang B; Deng J; Guan S; Ge M; Wang X; Xu B; Han Y
Catheter Cardiovasc Interv; 2015 Mar; 85 Suppl 1():744-51. PubMed ID: 25630447
[TBL] [Abstract][Full Text] [Related]
29. Elutax paclitaxel-eluting balloon followed by bare-metal stent compared with Xience V drug-eluting stent in the treatment of de novo coronary stenosis: a randomized trial.
Liistro F; Porto I; Angioli P; Grotti S; Ducci K; Falsini G; Bolognese L
Am Heart J; 2013 Nov; 166(5):920-6. PubMed ID: 24176449
[TBL] [Abstract][Full Text] [Related]
30. Head-to-head comparison of the neointimal response between metallic and bioresorbable everolimus-eluting scaffolds using optical coherence tomography.
Gomez-Lara J; Brugaletta S; Farooq V; Onuma Y; Diletti R; Windecker S; Thuesen L; McClean D; Koolen J; Whitbourn R; Dudek D; Smits PC; Chevalier B; Regar E; Veldhof S; Rapoza R; Ormiston JA; Garcia-Garcia HM; Serruys PW
JACC Cardiovasc Interv; 2011 Dec; 4(12):1271-80. PubMed ID: 22192368
[TBL] [Abstract][Full Text] [Related]
31. Mechanisms of Very Late Drug-Eluting Stent Thrombosis Assessed by Optical Coherence Tomography.
Taniwaki M; Radu MD; Zaugg S; Amabile N; Garcia-Garcia HM; Yamaji K; Jørgensen E; Kelbæk H; Pilgrim T; Caussin C; Zanchin T; Veugeois A; Abildgaard U; Jüni P; Cook S; Koskinas KC; Windecker S; Räber L
Circulation; 2016 Feb; 133(7):650-60. PubMed ID: 26762519
[TBL] [Abstract][Full Text] [Related]
32. Evaluation in 3 months duration of neointimal coverage after zotarolimus-eluting stent implantation by optical coherence tomography: the ENDEAVOR OCT trial.
Kim JS; Jang IK; Fan C; Kim TH; Kim JS; Park SM; Choi EY; Lee SH; Ko YG; Choi D; Hong MK; Jang Y
JACC Cardiovasc Interv; 2009 Dec; 2(12):1240-7. PubMed ID: 20129551
[TBL] [Abstract][Full Text] [Related]
33. Early coverage of drug-eluting stents analysed by optical coherence tomography: evidence of the impact of stent apposition and strut characteristics on the neointimal healing process.
Lee R; Foin N; Ng J; Allen J; Soh N; Ang I; Shim W; Torii R; Wong P
EuroIntervention; 2016 Aug; 12(5):e605-14. PubMed ID: 27497360
[TBL] [Abstract][Full Text] [Related]
34. Optical coherence tomography assessment of in vivo vascular response after implantation of overlapping bare-metal and drug-eluting stents.
Guagliumi G; Musumeci G; Sirbu V; Bezerra HG; Suzuki N; Fiocca L; Matiashvili A; Lortkipanidze N; Trivisonno A; Valsecchi O; Biondi-Zoccai G; Costa MA;
JACC Cardiovasc Interv; 2010 May; 3(5):531-9. PubMed ID: 20488410
[TBL] [Abstract][Full Text] [Related]
35. Very early tissue coverage after drug-eluting stent implantation: an optical coherence tomography study.
Takahara M; Kitahara H; Nishi T; Miura K; Miyayama T; Sugimoto K; Nakayama T; Fujimoto Y; Kobayashi Y
Int J Cardiovasc Imaging; 2017 Jan; 33(1):25-30. PubMed ID: 27601229
[TBL] [Abstract][Full Text] [Related]
36. OCT analysis in patients with very late stent thrombosis.
Kang SJ; Lee CW; Song H; Ahn JM; Kim WJ; Lee JY; Park DW; Lee SW; Kim YH; Mintz GS; Park SW; Park SJ
JACC Cardiovasc Imaging; 2013 Jun; 6(6):695-703. PubMed ID: 23643282
[TBL] [Abstract][Full Text] [Related]
37. Optical coherence tomography (OCT) in PCI for in-stent restenosis (ISR): rationale and design of the SEDUCE (Safety and Efficacy of a Drug elUting balloon in Coronary artery rEstenosis) study.
Adriaenssens T; Dens J; Ughi G; Coosemans M; Onsea K; Dubois C; Sinnaeve P; Vrolix M; Desmet W
EuroIntervention; 2011 May; 7 Suppl K():K100-5. PubMed ID: 22027717
[TBL] [Abstract][Full Text] [Related]
38. Evaluation of Early Healing Profile and Neointimal Transformation Over 24 Months Using Longitudinal Sequential Optical Coherence Tomography Assessments and 3-Year Clinical Results of the New Dual-Therapy Endothelial Progenitor Cell Capturing Sirolimus-Eluting Combo Stent: The EGO-Combo Study.
Lee SW; Lam SC; Tam FC; Chan KK; Shea CP; Kong SL; Wong AY; Yung A; Zhang LW; Tse HF; Wu KK; Chan R; Haude M; Mehran R; Mintz GS; Maehara A
Circ Cardiovasc Interv; 2016 Jul; 9(7):. PubMed ID: 27418609
[TBL] [Abstract][Full Text] [Related]
39. First results of the DEB-AMI (drug eluting balloon in acute ST-segment elevation myocardial infarction) trial: a multicenter randomized comparison of drug-eluting balloon plus bare-metal stent versus bare-metal stent versus drug-eluting stent in primary percutaneous coronary intervention with 6-month angiographic, intravascular, functional, and clinical outcomes.
Belkacemi A; Agostoni P; Nathoe HM; Voskuil M; Shao C; Van Belle E; Wildbergh T; Politi L; Doevendans PA; Sangiorgi GM; Stella PR
J Am Coll Cardiol; 2012 Jun; 59(25):2327-37. PubMed ID: 22503057
[TBL] [Abstract][Full Text] [Related]
40. Coronary responses and differential mechanisms of late stent thrombosis attributed to first-generation sirolimus- and paclitaxel-eluting stents.
Nakazawa G; Finn AV; Vorpahl M; Ladich ER; Kolodgie FD; Virmani R
J Am Coll Cardiol; 2011 Jan; 57(4):390-8. PubMed ID: 21251578
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]