These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

128 related articles for article (PubMed ID: 22131279)

  • 1. Preparation of high-quality ultrathin transmission electron microscopy specimens of a nanocrystalline metallic powder.
    Riedl T; Gemming T; Mickel C; Eymann K; Kirchner A; Kieback B
    Microsc Res Tech; 2012 Jun; 75(6):711-9. PubMed ID: 22131279
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Transmission electron microscopy and atom probe specimen preparation from mechanically alloyed powder using the focused ion-beam lift-out technique.
    Choi PP; Kwon YS; Kim JS; Al-Kassab T
    J Electron Microsc (Tokyo); 2007 Apr; 56(2):43-9. PubMed ID: 17928320
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Application of focused ion beam to atom probe tomography specimen preparation from mechanically alloyed powders.
    Choi PP; Al-Kassab T; Kwon YS; Kim JS; Kirchheim R
    Microsc Microanal; 2007 Oct; 13(5):347-53. PubMed ID: 17900385
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Combining Ar ion milling with FIB lift-out techniques to prepare high quality site-specific TEM samples.
    Huang Z
    J Microsc; 2004 Sep; 215(Pt 3):219-23. PubMed ID: 15312185
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Optimization of the preparation of GaN-based specimens with low-energy ion milling for (S)TEM.
    Mehrtens T; Bley S; Venkata Satyam P; Rosenauer A
    Micron; 2012 Aug; 43(8):902-9. PubMed ID: 22475986
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Site-specific Transmission Electron Microscope Characterization of Micrometer-sized Particles Using the Focused Ion Beam Lift-out Technique.
    Lomness JK; Giannuzzi LA; Hampton MD
    Microsc Microanal; 2001 Sep; 7(5):418-423. PubMed ID: 12597804
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Quantitative HRTEM analysis of FIB prepared specimens.
    Baram M; Kaplan WD
    J Microsc; 2008 Dec; 232(3):395-405. PubMed ID: 19094016
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Ultrathin specimen preparation by a low-energy Ar-ion milling method.
    Mitome M
    Microscopy (Oxf); 2013 Apr; 62(2):321-6. PubMed ID: 23155112
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Novel Method for Preparing Transmission Electron Microscopy Samples of Micrometer-Sized Powder Particles by Using Focused Ion Beam.
    Kim TH; Kang MC; Jung GB; Kim DS; Yang CW
    Microsc Microanal; 2017 Oct; 23(5):1055-1060. PubMed ID: 28899437
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Focused ion beam milling and ultramicrotomy of mineralised ivory dentine for analytical transmission electron microscopy.
    Jantou V; Turmaine M; West GD; Horton MA; McComb DW
    Micron; 2009 Jun; 40(4):495-501. PubMed ID: 19157888
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Cross-sectional Specimen Preparation and Observation of a Plasma Sprayed Coating Using a Focused Ion Beam/Transmission Electron Microscopy System.
    Yaguchi T; Kamino T; Sasaki M; Barbezat G; Urao R
    Microsc Microanal; 2000 May; 6(3):218-223. PubMed ID: 10790490
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Imaging thin films of nanoporous low-k dielectrics: comparison between ultramicrotomy and focused ion beam preparations for transmission electron microscopy.
    Thompson LE; Rice PM; Delenia E; Lee VY; Brock PJ; Magbitang TP; Dubois G; Volksen W; Miller RD; Kim HC
    Microsc Microanal; 2006 Apr; 12(2):156-9. PubMed ID: 17481352
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Convenient preparation of high-quality specimens for annealing experiments in the transmission electron microscope.
    Duchamp M; Xu Q; Dunin-Borkowski RE
    Microsc Microanal; 2014 Dec; 20(6):1638-45. PubMed ID: 25372115
    [TBL] [Abstract][Full Text] [Related]  

  • 14. TEM foil preparation of sub-micrometre sized individual grains by focused ion beam technique.
    Holzapfel C; Soldera F; Vollmer C; Hoppe P; Mücklich F
    J Microsc; 2009 Jul; 235(1):59-66. PubMed ID: 19566627
    [TBL] [Abstract][Full Text] [Related]  

  • 15. High contrast hollow-cone dark field transmission electron microscopy for nanocrystalline grain size quantification.
    Yao B; Sun T; Warren A; Heinrich H; Barmak K; Coffey KR
    Micron; 2010 Apr; 41(3):177-82. PubMed ID: 20018512
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Sample preparation for atomic-resolution STEM at low voltages by FIB.
    Schaffer M; Schaffer B; Ramasse Q
    Ultramicroscopy; 2012 Mar; 114():62-71. PubMed ID: 22356790
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Improved focused ion beam target preparation of (S)TEM specimen--a method for obtaining ultrathin lamellae.
    Lechner L; Biskupek J; Kaiser U
    Microsc Microanal; 2012 Apr; 18(2):379-84. PubMed ID: 22436335
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Plan-view preparation of TEM specimens from thin films using adhesive tape.
    Czigány Z
    Microsc Microanal; 2011 Dec; 17(6):886-8. PubMed ID: 22000156
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Comparison of TEM specimen preparation of perovskite thin films by tripod polishing and conventional ion milling.
    Eberg E; Monsen AF; Tybell T; van Helvoort AT; Holmestad R
    J Electron Microsc (Tokyo); 2008 Dec; 57(6):175-9. PubMed ID: 18815212
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Crystallographic analysis of thin specimens.
    Sivel VG; Tichelaar FD; Mohdadi H; Alkemade PF; Zandbergen HW
    J Microsc; 2005 May; 218(Pt 2):115-24. PubMed ID: 15857373
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.