These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

143 related articles for article (PubMed ID: 22134299)

  • 1. Life-threatening complication of recurrent laryngeal nerve monitoring with EMG reinforced silicone ETT.
    Oysu C; Demir K
    J Craniofac Surg; 2011 Nov; 22(6):2419-21. PubMed ID: 22134299
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Inability to ventilate while using a silicone-based endotracheal tube.
    Gleich SJ; Nicholson WT; Jacobs TM; Hofer RE; Sprung J
    J Clin Anesth; 2008 Aug; 20(5):389-392. PubMed ID: 18761252
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [Continuous monitoring of the recurrent laryngeal nerve].
    Lamadé W; Brandner R; Brauer M; Hund E; Klar E; Herfarth C
    Langenbecks Arch Chir Suppl Kongressbd; 1998; 115():1055-7. PubMed ID: 9931788
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Use of the GlideScope for placement of a recurrent laryngeal nerve monitoring endotracheal tube.
    Berkow L; Dackiw AP; Tufano RP
    J Clin Anesth; 2011 Feb; 23(1):81-3. PubMed ID: 21296257
    [No Abstract]   [Full Text] [Related]  

  • 5. [New aspects in surgery of the thyroid gland with intraoperative monitoring of the recurrent laryngeal nerve].
    Tschopp K; Probst R
    Laryngorhinootologie; 1994 Nov; 73(11):568-72. PubMed ID: 7818740
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Real-time monitoring of the recurrent laryngeal nerve: an observational clinical trial.
    Ulmer C; Koch KP; Seimer A; Molnar V; Meyding-Lamadé U; Thon KP; Lamadé W
    Surgery; 2008 Mar; 143(3):359-65. PubMed ID: 18291257
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Case study involving suctioning of an electromyographic endotracheal tube.
    Evanina EY; Hanisak JL
    AANA J; 2005 Apr; 73(2):111-3. PubMed ID: 15835830
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [Recurrent nerve palsy after endotracheal intubation].
    Otani S; Fujii H; Kurasako N; Ishizu T; Tanaka T; Kousogabe Y; Tokioka H; Namba M
    Masui; 1998 Mar; 47(3):350-5. PubMed ID: 9560550
    [TBL] [Abstract][Full Text] [Related]  

  • 9. An unusual case of cuff herniation.
    Treffers R; de Lange JJ
    Acta Anaesthesiol Belg; 1989; 40(1):87-90. PubMed ID: 2728836
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [Intraoperative neuromonitoring of the recurrent laryngeal nerve - results and learning curve].
    Jonas J; Bähr R
    Zentralbl Chir; 2006 Dec; 131(6):443-8. PubMed ID: 17206561
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Transcricothyroid electromyographic monitoring of the recurrent laryngeal nerve.
    Alon EE; Hinni ML
    Laryngoscope; 2009 Oct; 119(10):1918-21. PubMed ID: 19650135
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Endotracheal tubes: old and new.
    Haas CF; Eakin RM; Konkle MA; Blank R
    Respir Care; 2014 Jun; 59(6):933-52; discussion 952-5. PubMed ID: 24891200
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Intraoperative neuromonitoring of the recurrent laryngeal nerve--routine use in thyroid gland surgery].
    Kienast A; Richter C; Neumann HJ
    Langenbecks Arch Chir Suppl Kongressbd; 1998; 115():1058-60. PubMed ID: 9931789
    [TBL] [Abstract][Full Text] [Related]  

  • 14. The supine-to-prone position change induces modification of endotracheal tube cuff pressure accompanied by tube displacement.
    Minonishi T; Kinoshita H; Hirayama M; Kawahito S; Azma T; Hatakeyama N; Fujiwara Y
    J Clin Anesth; 2013 Feb; 25(1):28-31. PubMed ID: 23391343
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Nerve monitoring and stimulation during endoscopic neck surgery in the pig.
    Grunebaum LD; Rosen D; Krein HD; Keane WM; Curtis M; Tereschuk DA; Pribitkin EA
    Laryngoscope; 2005 Apr; 115(4):712-6. PubMed ID: 15805886
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Airway obstruction caused by endotracheal tube cuff herniation during creation of tracheal stoma.
    Kao MC; Yu YS; Liu HT; Tsai SK; Lin SM; Huang YC
    Acta Anaesthesiol Taiwan; 2005 Mar; 43(1):59-62. PubMed ID: 15869007
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A method of securing the Xomed endotracheal tube for accurate monitoring of the recurrent laryngeal nerve.
    Nekhendzy V; Lopez JR; Damrose EJ
    J Clin Anesth; 2012 May; 24(3):259-60. PubMed ID: 22495085
    [No Abstract]   [Full Text] [Related]  

  • 18. Vagal nerve monitoring in surgery of the skull base: a comparison of efficacy of three techniques.
    Jackson LE; Roberson JB
    Am J Otol; 1999 Sep; 20(5):649-56. PubMed ID: 10503589
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Intraoperative monitoring of recurrent laryngeal nerve function.
    Djohan RS; Rodriguez HE; Connolly MM; Childers SJ; Braverman B; Podbielski FJ
    Am Surg; 2000 Jun; 66(6):595-7. PubMed ID: 10888139
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Two cases of intraoperative herniation of the endotracheal tube cuff.
    Bergadano A; Moens Y; Schatzmann U
    Schweiz Arch Tierheilkd; 2004 Dec; 146(12):565-9. PubMed ID: 15630897
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.