These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

214 related articles for article (PubMed ID: 22142032)

  • 1. Is the pleth variability index a surrogate for pulse pressure variation in a pediatric population undergoing spine fusion?
    Feldman JM; Sussman E; Singh D; Friedman BJ
    Paediatr Anaesth; 2012 Mar; 22(3):250-5. PubMed ID: 22142032
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Comparison of pulse pressure variation and pleth variability index in the prone position in pediatric patients under 2 years old.
    Ji SH; Song IK; Jang YE; Kim EH; Lee JH; Kim JT; Kim HS
    Korean J Anesthesiol; 2019 Oct; 72(5):466-471. PubMed ID: 31216847
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Assessment of the agreement between photoplethysmographic and arterial waveform respiratory variation in patients undergoing spine surgery.
    Thiele RH; Colquhoun DA; Forkin KT; Durieux ME
    J Med Eng Technol; 2013 Oct; 37(7):409-15. PubMed ID: 23941460
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Accuracy of stroke volume variation compared with pleth variability index to predict fluid responsiveness in mechanically ventilated patients undergoing major surgery.
    Zimmermann M; Feibicke T; Keyl C; Prasser C; Moritz S; Graf BM; Wiesenack C
    Eur J Anaesthesiol; 2010 Jun; 27(6):555-61. PubMed ID: 20035228
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Prediction of responsiveness to an intravenous fluid challenge in patients after cardiac surgery with cardiopulmonary bypass: a comparison between arterial pulse pressure variation and digital plethysmographic variability index.
    Fischer MO; Pelissier A; Bohadana D; Gérard JL; Hanouz JL; Fellahi JL
    J Cardiothorac Vasc Anesth; 2013 Dec; 27(6):1087-93. PubMed ID: 23992654
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Effects of stroke volume variation, pulse pressure variation, and pleth variability index in predicting fluid responsiveness during different positive end expiratory pressure in prone position.
    Chen Y; Fu Q; Mi WD
    Zhongguo Yi Xue Ke Xue Yuan Xue Bao; 2015 Apr; 37(2):179-84. PubMed ID: 25936706
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Pleth variability index is a weak predictor of fluid responsiveness in patients receiving norepinephrine.
    Monnet X; Guérin L; Jozwiak M; Bataille A; Julien F; Richard C; Teboul JL
    Br J Anaesth; 2013 Feb; 110(2):207-13. PubMed ID: 23103777
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Accuracy of the pleth variability index to predict fluid responsiveness depends on the perfusion index.
    Broch O; Bein B; Gruenewald M; Höcker J; Schöttler J; Meybohm P; Steinfath M; Renner J
    Acta Anaesthesiol Scand; 2011 Jul; 55(6):686-93. PubMed ID: 21480831
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Comparison of pulse pressure variation, stroke volume variation, and plethysmographic variability index in pediatric patients undergoing craniotomy].
    Liu YF; Song LL; Xing MW; Cai LX; Wang DX
    Beijing Da Xue Xue Bao Yi Xue Ban; 2021 Oct; 53(5):946-951. PubMed ID: 34650300
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Validation of pulse pressure variation and corrected flow time as predictors of fluid responsiveness in patients in the prone position.
    Yang SY; Shim JK; Song Y; Seo SJ; Kwak YL
    Br J Anaesth; 2013 May; 110(5):713-20. PubMed ID: 23274783
    [TBL] [Abstract][Full Text] [Related]  

  • 11. The ability of pleth variability index to predict the hemodynamic effects of positive end-expiratory pressure in mechanically ventilated patients under general anesthesia.
    Desebbe O; Boucau C; Farhat F; Bastien O; Lehot JJ; Cannesson M
    Anesth Analg; 2010 Mar; 110(3):792-8. PubMed ID: 20185658
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Does the Pleth variability index indicate the respiratory-induced variation in the plethysmogram and arterial pressure waveforms?
    Cannesson M; Delannoy B; Morand A; Rosamel P; Attof Y; Bastien O; Lehot JJ
    Anesth Analg; 2008 Apr; 106(4):1189-94, table of contents. PubMed ID: 18349191
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Pulse pressure variation and pleth variability index as predictors of fluid responsiveness in patients undergoing spinal surgery in the prone position.
    Kim DH; Shin S; Kim JY; Kim SH; Jo M; Choi YS
    Ther Clin Risk Manag; 2018; 14():1175-1183. PubMed ID: 30013353
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Cephalic versus digital plethysmographic variability index measurement: a comparative pilot study in cardiac surgery patients.
    Fischer MO; Pellissier A; Saplacan V; Gérard JL; Hanouz JL; Fellahi JL
    J Cardiothorac Vasc Anesth; 2014 Dec; 28(6):1510-5. PubMed ID: 25263772
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Goal-directed fluid management based on the pulse oximeter-derived pleth variability index reduces lactate levels and improves fluid management.
    Forget P; Lois F; de Kock M
    Anesth Analg; 2010 Oct; 111(4):910-4. PubMed ID: 20705785
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Abilities of pulse pressure variations and stroke volume variations to predict fluid responsiveness in prone position during scoliosis surgery.
    Biais M; Bernard O; Ha JC; Degryse C; Sztark F
    Br J Anaesth; 2010 Apr; 104(4):407-13. PubMed ID: 20190260
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Ventilation-Induced Modulation of Pulse Oximeter Waveforms: A Method for the Assessment of Early Changes in Intravascular Volume During Spinal Fusion Surgery in Pediatric Patients.
    Alian AA; Atteya G; Gaal D; Golembeski T; Smith BG; Dai F; Silverman DG; Shelley K
    Anesth Analg; 2016 Aug; 123(2):346-56. PubMed ID: 27284998
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Pulse Pressure Variations and Plethysmographic Variability Index Measured at Ear Are Able to Predict Fluid Responsiveness in the Sitting Position for Neurosurgery.
    Bapteste L; Carrillon R; Javelier S; Guyotat J; Desgranges FP; Lehot JJ; Lukaszewicz AC
    J Neurosurg Anesthesiol; 2020 Jul; 32(3):263-267. PubMed ID: 30789383
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Pleth variability index to monitor the respiratory variations in the pulse oximeter plethysmographic waveform amplitude and predict fluid responsiveness in the operating theatre.
    Cannesson M; Desebbe O; Rosamel P; Delannoy B; Robin J; Bastien O; Lehot JJ
    Br J Anaesth; 2008 Aug; 101(2):200-6. PubMed ID: 18522935
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Pleth variability index predicts fluid responsiveness in mechanically ventilated adults during general anesthesia for noncardiac surgery.
    Siswojo AS; Wong DM; Phan TD; Kluger R
    J Cardiothorac Vasc Anesth; 2014 Dec; 28(6):1505-9. PubMed ID: 25169895
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.