BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

165 related articles for article (PubMed ID: 22146391)

  • 1. Magnetic resonance force microscopy of paramagnetic electron spins at millikelvin temperatures.
    Vinante A; Wijts G; Usenko O; Schinkelshoek L; Oosterkamp TH
    Nat Commun; 2011 Dec; 2():572. PubMed ID: 22146391
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Nuclear magnetic resonance imaging with 90-nm resolution.
    Mamin HJ; Poggio M; Degen CL; Rugar D
    Nat Nanotechnol; 2007 May; 2(5):301-6. PubMed ID: 18654288
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Magnetic resonance force microscopy with a ferromagnetic tip mounted on the force detector.
    Zhang Z; Hammel PC
    Solid State Nucl Magn Reson; 1998 Mar; 11(1-2):65-72. PubMed ID: 9650791
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Force microscopy: magnetic tips probe the nanoworld.
    Meyer E; Rast S
    Nat Nanotechnol; 2007 May; 2(5):267-8. PubMed ID: 18654278
    [No Abstract]   [Full Text] [Related]  

  • 5. Magnetic Resonance Force Microscopy Detected Long-Lived Spin Magnetization.
    Chen L; Longenecker JG; Moore EW; Marohn JA
    IEEE Trans Magn; 2013 Jul; 49(7):3528-3532. PubMed ID: 26097251
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Single spin detection by magnetic resonance force microscopy.
    Rugar D; Budakian R; Mamin HJ; Chui BW
    Nature; 2004 Jul; 430(6997):329-32. PubMed ID: 15254532
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Magnetism in SQUIDs at millikelvin temperatures.
    Sendelbach S; Hover D; Kittel A; Mück M; Martinis JM; McDermott R
    Phys Rev Lett; 2008 Jun; 100(22):227006. PubMed ID: 18643451
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Reaching the quantum limit of sensitivity in electron spin resonance.
    Bienfait A; Pla JJ; Kubo Y; Stern M; Zhou X; Lo CC; Weis CD; Schenkel T; Thewalt ML; Vion D; Esteve D; Julsgaard B; Mølmer K; Morton JJ; Bertet P
    Nat Nanotechnol; 2016 Mar; 11(3):253-7. PubMed ID: 26657787
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Advances in mechanical detection of magnetic resonance.
    Kuehn S; Hickman SA; Marohn JA
    J Chem Phys; 2008 Feb; 128(5):052208. PubMed ID: 18266413
    [TBL] [Abstract][Full Text] [Related]  

  • 10. The Bloch equations in high-gradient magnetic resonance force microscopy: theory and experiment.
    Dougherty WM; Bruland KJ; Chao SH; Garbini JL; Jensen SE; Sidles JA
    J Magn Reson; 2000 Mar; 143(1):106-19. PubMed ID: 10698652
    [TBL] [Abstract][Full Text] [Related]  

  • 11. High-gradient nanomagnets on cantilevers for sensitive detection of nuclear magnetic resonance.
    Longenecker JG; Mamin HJ; Senko AW; Chen L; Rettner CT; Rugar D; Marohn JA
    ACS Nano; 2012 Nov; 6(11):9637-45. PubMed ID: 23033869
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Dynamic nuclear polarization in a magnetic resonance force microscope experiment.
    Isaac CE; Gleave CM; Nasr PT; Nguyen HL; Curley EA; Yoder JL; Moore EW; Chen L; Marohn JA
    Phys Chem Chem Phys; 2016 Apr; 18(13):8806-19. PubMed ID: 26964007
    [TBL] [Abstract][Full Text] [Related]  

  • 13. K-band single-chip electron spin resonance detector.
    Anders J; Angerhofer A; Boero G
    J Magn Reson; 2012 Apr; 217():19-26. PubMed ID: 22405529
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A Non-Perturbative, Low-Noise Surface Coating for Sensitive Force-Gradient Detection of Electron Spin Resonance in Thin Films.
    Boucher MC; Isaac CE; Sun P; Borbat PP; Marohn JA
    ACS Nano; 2023 Jan; ():. PubMed ID: 36625878
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Operation of a silicon quantum processor unit cell above one kelvin.
    Yang CH; Leon RCC; Hwang JCC; Saraiva A; Tanttu T; Huang W; Camirand Lemyre J; Chan KW; Tan KY; Hudson FE; Itoh KM; Morello A; Pioro-Ladrière M; Laucht A; Dzurak AS
    Nature; 2020 Apr; 580(7803):350-354. PubMed ID: 32296190
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Quantum control of hybrid nuclear-electronic qubits.
    Morley GW; Lueders P; Mohammady MH; Balian SJ; Aeppli G; Kay CW; Witzel WM; Jeschke G; Monteiro TS
    Nat Mater; 2013 Feb; 12(2):103-7. PubMed ID: 23202370
    [TBL] [Abstract][Full Text] [Related]  

  • 17. SQUID detected NMR and NQR. Superconducting Quantum Interference Device.
    Augustine MP; TonThat DM; Clarke J
    Solid State Nucl Magn Reson; 1998 Mar; 11(1-2):139-56. PubMed ID: 9650797
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Detecting spins by their fluorescence with a microwave photon counter.
    Albertinale E; Balembois L; Billaud E; Ranjan V; Flanigan D; Schenkel T; Estève D; Vion D; Bertet P; Flurin E
    Nature; 2021 Dec; 600(7889):434-438. PubMed ID: 34912088
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Nanoscale Fourier-transform imaging with magnetic resonance force microscopy.
    Kempf JG; Marohn JA
    Phys Rev Lett; 2003 Feb; 90(8):087601. PubMed ID: 12633459
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Observation of an anomalous decoherence effect in a quantum bath at room temperature.
    Huang P; Kong X; Zhao N; Shi F; Wang P; Rong X; Liu RB; Du J
    Nat Commun; 2011 Dec; 2():570. PubMed ID: 22146389
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.