287 related articles for article (PubMed ID: 22149407)
21. The diagnostic value of total respiratory impedance by impulse oscillometry in chronic obstructive lung disease.
Wang M; Niu S; Li Y; Zhang Z; Bai C
Chin Med J (Engl); 1999 Nov; 112(11):982-4. PubMed ID: 11721479
[TBL] [Abstract][Full Text] [Related]
22. Responsiveness to bronchodilator procaterol in COPD as assessed by forced oscillation technique.
Ito S; Uchida A; Isobe Y; Hasegawa Y
Respir Physiol Neurobiol; 2017 Jun; 240():41-47. PubMed ID: 28238903
[TBL] [Abstract][Full Text] [Related]
23. Emphysema and airway disease affect within-breath changes in respiratory resistance in COPD patients.
Hasegawa K; Sato S; Tanimura K; Fuseya Y; Uemasu K; Sato A; Hirai T; Mishima M; Muro S
Respirology; 2015 Jul; 20(5):775-81. PubMed ID: 25824559
[TBL] [Abstract][Full Text] [Related]
24. Impact of exacerbations on respiratory system impedance measured by a forced oscillation technique in COPD: a prospective observational study.
Kamada T; Kaneko M; Tomioka H
Int J Chron Obstruct Pulmon Dis; 2017; 12():509-516. PubMed ID: 28223791
[TBL] [Abstract][Full Text] [Related]
25. Comparison of impedance measured by the forced oscillation technique and pulmonary functions, including static lung compliance, in obstructive and interstitial lung disease.
Takeichi N; Yamazaki H; Fujimoto K
Int J Chron Obstruct Pulmon Dis; 2019; 14():1109-1118. PubMed ID: 31213791
[No Abstract] [Full Text] [Related]
26. [Clinical application of the forced oscillation technique for titration of pressure support levels in chronic obstructive pulmonary disease patients during nasal noninvasive positive pressure ventilation].
Wang H; Chen RC; He S; Luo Q
Zhonghua Jie He He Hu Xi Za Zhi; 2009 Jan; 32(1):21-6. PubMed ID: 19484957
[TBL] [Abstract][Full Text] [Related]
27. Effect of increasing respiratory rate on airway resistance and reactance in COPD patients.
Nakagawa M; Hattori N; Haruta Y; Sugiyama A; Iwamoto H; Ishikawa N; Fujitaka K; Murai H; Tanaka J; Kohno N
Respirology; 2015 Jan; 20(1):87-94. PubMed ID: 25251948
[TBL] [Abstract][Full Text] [Related]
28. Usefulness of Colored 3D Imaging of Respiratory Impedance in Asthma.
Shirai T; Mori K; Mikamo M; Shishido Y; Akita T; Morita S; Asada K; Fujii M; Suda T; Chida K
Allergy Asthma Immunol Res; 2013 Sep; 5(5):322-8. PubMed ID: 24003390
[TBL] [Abstract][Full Text] [Related]
29. Association between respiratory impedance measured by forced oscillation technique and exacerbations in patients with COPD.
Yamagami H; Tanaka A; Kishino Y; Mikuni H; Kawahara T; Ohta S; Yamamoto M; Suzuki S; Ohnishi T; Sagara H
Int J Chron Obstruct Pulmon Dis; 2018; 13():79-89. PubMed ID: 29317813
[TBL] [Abstract][Full Text] [Related]
30. Within- and between-day variability of respiratory impedance, using impulse oscillometry in adolescent asthmatics.
Goldman MD; Carter R; Klein R; Fritz G; Carter B; Pachucki P
Pediatr Pulmonol; 2002 Oct; 34(4):312-9. PubMed ID: 12205573
[TBL] [Abstract][Full Text] [Related]
31. Airway dynamics in COPD patients by within-breath impedance tracking: effects of continuous positive airway pressure.
Lorx A; Czövek D; Gingl Z; Makan G; Radics B; Bartusek D; Szigeti S; Gál J; Losonczy G; Sly PD; Hantos Z
Eur Respir J; 2017 Feb; 49(2):. PubMed ID: 28202552
[TBL] [Abstract][Full Text] [Related]
32. Dynamic change in respiratory resistance during inspiratory and expiratory phases of tidal breathing in patients with chronic obstructive pulmonary disease.
Yamauchi Y; Kohyama T; Jo T; Nagase T
Int J Chron Obstruct Pulmon Dis; 2012; 7():259-69. PubMed ID: 22589578
[TBL] [Abstract][Full Text] [Related]
33. I Say IOS You Say AOS: Comparative Bias in Respiratory Impedance Measurements.
Kuo CR; Jabbal S; Lipworth B
Lung; 2019 Aug; 197(4):473-481. PubMed ID: 31273438
[TBL] [Abstract][Full Text] [Related]
34. Procedures to improve the repeatability of forced oscillation measurements in school-aged children.
Robinson PD; Turner M; Brown NJ; Salome C; Berend N; Marks GB; King GG
Respir Physiol Neurobiol; 2011 Jul; 177(2):199-206. PubMed ID: 21320646
[TBL] [Abstract][Full Text] [Related]
35. Evaluation of respiratory impedance in asthma and COPD by an impulse oscillation system.
Kanda S; Fujimoto K; Komatsu Y; Yasuo M; Hanaoka M; Kubo K
Intern Med; 2010; 49(1):23-30. PubMed ID: 20045997
[TBL] [Abstract][Full Text] [Related]
36. Fluctuations and determinism of respiratory impedance in asthma and chronic obstructive pulmonary disease.
Muskulus M; Slats AM; Sterk PJ; Verduyn-Lunel S
J Appl Physiol (1985); 2010 Dec; 109(6):1582-91. PubMed ID: 20813978
[TBL] [Abstract][Full Text] [Related]
37. Respiratory mechanics in ventilated COPD patients: forced oscillation versus occlusion techniques.
Farré R; Ferrer M; Rotger M; Torres A; Navajas D
Eur Respir J; 1998 Jul; 12(1):170-6. PubMed ID: 9701433
[TBL] [Abstract][Full Text] [Related]
38. Reproducibility and responsiveness of airway impedance measures derived from the forced oscillation technique across different operating lung volumes.
Aitken CR; Pathangey G; Stamos M; Kim CH; Johnson BD; Stewart GM
Respir Physiol Neurobiol; 2024 Feb; 320():104200. PubMed ID: 38036081
[TBL] [Abstract][Full Text] [Related]
39. Reference values of total respiratory resistance and reactance between 4 and 26 Hz in children and adolescents aged 4-20 years.
Clément J; Dumoulin B; Gubbelmans R; Hendriks S; van de Woestijne KP
Bull Eur Physiopathol Respir; 1987; 23(5):441-8. PubMed ID: 3450326
[TBL] [Abstract][Full Text] [Related]
40. The feasibility of home monitoring of impedance with the forced oscillation technique in chronic obstructive pulmonary disease subjects.
Timmins SC; Diba C; Thamrin C; Berend N; Salome CM; King GG
Physiol Meas; 2013 Jan; 34(1):67-81. PubMed ID: 23248176
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]