BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

443 related articles for article (PubMed ID: 22149834)

  • 1. Calculation of k(Q(clin),Q(msr) ) (f(clin),f(msr) ) for several small detectors and for two linear accelerators using Monte Carlo simulations.
    Francescon P; Cora S; Satariano N
    Med Phys; 2011 Dec; 38(12):6513-27. PubMed ID: 22149834
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Monte Carlo calculated correction factors for diodes and ion chambers in small photon fields.
    Czarnecki D; Zink K
    Phys Med Biol; 2013 Apr; 58(8):2431-44. PubMed ID: 23514734
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A novel method for the determination of field output factors and output correction factors for small static fields for six diodes and a microdiamond detector in megavoltage photon beams.
    Casar B; Gershkevitsh E; Mendez I; Jurković S; Huq MS
    Med Phys; 2019 Feb; 46(2):944-963. PubMed ID: 30521073
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Monte Carlo computed machine-specific correction factors for reference dosimetry of TomoTherapy static beam for several ion chambers.
    Sterpin E; Mackie TR; Vynckier S
    Med Phys; 2012 Jul; 39(7):4066-72. PubMed ID: 22830739
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Correction-less dosimetry of nonstandard photon fields: a new criterion to determine the usability of radiation detectors.
    Kamio Y; Bouchard H
    Phys Med Biol; 2014 Sep; 59(17):4973-5002. PubMed ID: 25118890
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Determination of the KQclinfclin,Qmsr fmsr correction factors for detectors used with an 800 MU/min CyberKnife(®) system equipped with fixed collimators and a study of detector response to small photon beams using a Monte Carlo method.
    Moignier C; Huet C; Makovicka L
    Med Phys; 2014 Jul; 41(7):071702. PubMed ID: 24989371
    [TBL] [Abstract][Full Text] [Related]  

  • 7. On the output factor measurements of the CyberKnife iris collimator small fields: Experimental determination of the k(Q(clin),Q(msr) ) (f(clin),f(msr) ) correction factors for microchamber and diode detectors.
    Pantelis E; Moutsatsos A; Zourari K; Petrokokkinos L; Sakelliou L; Kilby W; Antypas C; Papagiannis P; Karaiskos P; Georgiou E; Seimenis I
    Med Phys; 2012 Aug; 39(8):4875-85. PubMed ID: 22894414
    [TBL] [Abstract][Full Text] [Related]  

  • 8. On the implementation of a recently proposed dosimetric formalism to a robotic radiosurgery system.
    Pantelis E; Moutsatsos A; Zourari K; Kilby W; Antypas C; Papagiannis P; Karaiskos P; Georgiou E; Sakelliou L
    Med Phys; 2010 May; 37(5):2369-79. PubMed ID: 20527571
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Monte-Carlo calculation of output correction factors for ionization chambers, solid-state detectors, and EBT3 film in small fields of high-energy photons.
    Klimanov VA; Kirpichev YS; Serikbekova ZK; Belousov AV; Krusanov GA; Walwyn-Salas G; Morozov VN; Kolyvanova MA
    J Appl Clin Med Phys; 2023 Jan; 24(1):e13753. PubMed ID: 35998153
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Output correction factors for small static fields in megavoltage photon beams for seven ionization chambers in two orientations - perpendicular and parallel.
    Casar B; Gershkevitsh E; Mendez I; Jurković S; Saiful Huq M
    Med Phys; 2020 Jan; 47(1):242-259. PubMed ID: 31677278
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Implementing a newly proposed Monte Carlo based small field dosimetry formalism for a comprehensive set of diode detectors.
    Cranmer-Sargison G; Weston S; Evans JA; Sidhu NP; Thwaites DI
    Med Phys; 2011 Dec; 38(12):6592-602. PubMed ID: 22149841
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Monte Carlo-based diode design for correction-less small field dosimetry.
    Charles PH; Crowe SB; Kairn T; Knight RT; Hill B; Kenny J; Langton CM; Trapp JV
    Phys Med Biol; 2013 Jul; 58(13):4501-12. PubMed ID: 23760107
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Field correction factors for a PTW-31016 Pinpoint ionization chamber for both flattened and unflattened beams. Study of the main sources of uncertainties.
    Puxeu-Vaqué J; Duch MA; Nailon WH; Cruz Lizuain M; Ginjaume M
    Med Phys; 2017 May; 44(5):1930-1938. PubMed ID: 28261817
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Output correction factors for nine small field detectors in 6 MV radiation therapy photon beams: a PENELOPE Monte Carlo study.
    Benmakhlouf H; Sempau J; Andreo P
    Med Phys; 2014 Apr; 41(4):041711. PubMed ID: 24694131
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Experimental determination of field factors ([Formula: see text]) for small radiotherapy beams using the daisy chain correction method.
    Lárraga-Gutiérrez JM
    Phys Med Biol; 2015 Aug; 60(15):5813-31. PubMed ID: 26161448
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Deriving detector-specific correction factors for rectangular small fields using a scintillator detector.
    Qin Y; Zhong H; Wen N; Snyder K; Huang Y; Chetty IJ
    J Appl Clin Med Phys; 2016 Nov; 17(6):379-391. PubMed ID: 27929510
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Monte carlo electron source model validation for an Elekta Precise linac.
    Ali OA; Willemse CA; Shaw W; O'Reilly FH; du Plessis FC
    Med Phys; 2011 May; 38(5):2366-73. PubMed ID: 21776771
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A virtual photon source model of an Elekta linear accelerator with integrated mini MLC for Monte Carlo based IMRT dose calculation.
    Sikora M; Dohm O; Alber M
    Phys Med Biol; 2007 Aug; 52(15):4449-63. PubMed ID: 17634643
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Assessment of the setup dependence of detector response functions for mega-voltage linear accelerators.
    Fox C; Simon T; Simon B; Dempsey JF; Kahler D; Palta JR; Liu C; Yan G
    Med Phys; 2010 Feb; 37(2):477-84. PubMed ID: 20229856
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Commissioning stereotactic radiosurgery beams using both experimental and theoretical methods.
    Ding GX; Duggan DM; Coffey CW
    Phys Med Biol; 2006 May; 51(10):2549-66. PubMed ID: 16675869
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 23.