BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

329 related articles for article (PubMed ID: 22157954)

  • 1. Novel pulsatile cerebrospinal fluid model to assess pressure manometry and fluid sampling through spinal needles of different gauge: support for the use of a 22 G spinal needle with a tapered 27 G pencil-point tip.
    Ginosar Y; Smith Y; Ben-Hur T; Lovett JM; Clements T; Ginosar YD; Davidson EM
    Br J Anaesth; 2012 Feb; 108(2):308-15. PubMed ID: 22157954
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A simple method of estimating cerebrospinal fluid pressure during lumbar puncture.
    Ellis RW; Strauss LC; Wiley JM; Killmond TM; Ellis RW
    Pediatrics; 1992 May; 89(5 Pt 1):895-7. PubMed ID: 1579400
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Finer gauge of cutting but not pencil-point needles correlate with lower incidence of post-dural puncture headache: a meta-regression analysis.
    Zorrilla-Vaca A; Healy R; Zorrilla-Vaca C
    J Anesth; 2016 Oct; 30(5):855-63. PubMed ID: 27468735
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Responses to dural puncture during institution of combined spinal-epidural analgesia: a comparison of 27 gauge pencil-point and 27 gauge cutting-edge needles.
    van den Berg AA; Ghatge S; Armendariz G; Cornelius D; Wang S
    Anaesth Intensive Care; 2011 Mar; 39(2):247-51. PubMed ID: 21485674
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Incidence of postdural puncture headache and backache following diagnostic/therapeutic lumbar puncture using a 22G cutting spinal needle, and after introduction of a 25G pencil point spinal needle.
    Lowery S; Oliver A
    Paediatr Anaesth; 2008 Mar; 18(3):230-4. PubMed ID: 18230066
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Dural tissue trauma and cerebrospinal fluid leak after epidural needle puncture: effect of needle design, angle, and bevel orientation.
    Angle PJ; Kronberg JE; Thompson DE; Ackerley C; Szalai JP; Duffin J; Faure P
    Anesthesiology; 2003 Dec; 99(6):1376-82. PubMed ID: 14639152
    [TBL] [Abstract][Full Text] [Related]  

  • 7. The use of the 25 Sprotte needle markedly reduces post-dural puncture headache in routine neurological practice.
    Bertolotto A; Malentacchi M; Capobianco M; di Sapio A; Malucchi S; Motuzova Y; Pulizzi A; Berchialla P; Sperli F
    Cephalalgia; 2016 Feb; 36(2):131-8. PubMed ID: 25908221
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The Impact of Spinal Needle Selection on Postdural Puncture Headache: A Meta-Analysis and Metaregression of Randomized Studies.
    Zorrilla-Vaca A; Mathur V; Wu CL; Grant MC
    Reg Anesth Pain Med; 2018 Jul; 43(5):502-508. PubMed ID: 29659437
    [TBL] [Abstract][Full Text] [Related]  

  • 9. The effect of needle size on cerebrospinal fluid collection time and post-dural puncture headache: A retrospective cohort study.
    van Dongen RM; Onderwater GLJ; Pelzer N; Zielman R; van Oosterhout WPJ; van Zwet EW; Ferrari MD; Terwindt GM
    Headache; 2021 Feb; 61(2):329-334. PubMed ID: 33452678
    [TBL] [Abstract][Full Text] [Related]  

  • 10. In vitro investigation of cerebrospinal fluid leakage after dural puncture with various spinal needles.
    Holst D; Möllmann M; Ebel C; Hausman R; Wendt M
    Anesth Analg; 1998 Dec; 87(6):1331-5. PubMed ID: 9842822
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Diagnostic lumbar puncture. Comparative study between 22-gauge pencil point and sharp bevel needle.
    Luostarinen L; Heinonen T; Luostarinen M; Salmivaara A
    J Headache Pain; 2005 Oct; 6(5):400-4. PubMed ID: 16362713
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Post-dural puncture headache in young adults: comparison of two small-gauge spinal catheters with different needle design.
    Gosch UW; Hueppe M; Hallschmid M; Born J; Schmucker P; Meier T
    Br J Anaesth; 2005 May; 94(5):657-61. PubMed ID: 15722381
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Atraumatic lumbar puncture needles: after all these years, are we still missing the point?
    Arendt K; Demaerschalk BM; Wingerchuk DM; Camann W
    Neurologist; 2009 Jan; 15(1):17-20. PubMed ID: 19131853
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Does Needle Gauge or Tip Design Prevent Postdural Puncture Headache?
    West JR; Oliver M
    Ann Emerg Med; 2019 Aug; 74(2):297-299. PubMed ID: 30770206
    [No Abstract]   [Full Text] [Related]  

  • 15. High success rate and low incidence of headache and neurological symptoms with two spinal needle designs in children.
    Kokki H; Turunen M; Heikkinen M; Reinikainen M; Laisalmi M
    Acta Anaesthesiol Scand; 2005 Oct; 49(9):1367-72. PubMed ID: 16146477
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Comparison of 26-gauge Atraucan and 25-gauge Whitacre needles: insertion characteristics and complications.
    Sharma SK; Gambling DR; Joshi GP; Sidawi JE; Herrera ER
    Can J Anaesth; 1995 Aug; 42(8):706-10. PubMed ID: 7586110
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Postdural puncture headache after lumbar puncture: do the gauge and the design of a spinal needle matter?
    Kuczkowski KM
    Am J Emerg Med; 2006 Oct; 24(6):757. PubMed ID: 16984859
    [No Abstract]   [Full Text] [Related]  

  • 18. Towards evidence-based emergency medicine: best BETs from the Manchester Royal Infirmary. BET 2: what gauge and type of lumbar puncture needle should we be using in the paediatric population to reduce the risk of postdural puncture headaches?
    Alcock A; Salter R
    Emerg Med J; 2013 Jan; 30(1):80-1. PubMed ID: 23275464
    [TBL] [Abstract][Full Text] [Related]  

  • 19. The PENCAN 25-gauge needle: a new pencil-point needle for spinal anesthesia tested in 1,193 patients.
    Krommendijk EJ; Verheijen R; van Dijk B; Spoelder EM; Gielen MJ; de Lange JJ
    Reg Anesth Pain Med; 1999; 24(1):43-50. PubMed ID: 9952094
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Post-lumbar puncture headache].
    Rodriques AM; Roy PM
    Rev Prat; 2007 Feb; 57(4):353-7. PubMed ID: 17455735
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 17.