203 related articles for article (PubMed ID: 22163559)
1. Enzyme immobilization strategies and electropolymerization conditions to control sensitivity and selectivity parameters of a polymer-enzyme composite glucose biosensor.
Rothwell SA; Killoran SJ; O'Neill RD
Sensors (Basel); 2010; 10(7):6439-62. PubMed ID: 22163559
[TBL] [Abstract][Full Text] [Related]
2. Glucose biosensor based on immobilization of glucose oxidase in poly(o-aminophenol) film on polypyrrole-Pt nanocomposite modified glassy carbon electrode.
Li J; Lin X
Biosens Bioelectron; 2007 Jun; 22(12):2898-905. PubMed ID: 17215117
[TBL] [Abstract][Full Text] [Related]
3. Amperometric glucose biosensor based on electroconductive hydrogels.
Kotanen CN; Tlili C; Guiseppi-Elie A
Talanta; 2013 Jan; 103():228-35. PubMed ID: 23200382
[TBL] [Abstract][Full Text] [Related]
4. Contributions by a novel edge effect to the permselectivity of an electrosynthesized polymer for microbiosensor applications.
Rothwell SA; Kinsella ME; Zain ZM; Serra PA; Rocchitta G; Lowry JP; O'Neill RD
Anal Chem; 2009 May; 81(10):3911-8. PubMed ID: 19371060
[TBL] [Abstract][Full Text] [Related]
5. Immobilization of enzymes through one-pot chemical preoxidation and electropolymerization of dithiols in enzyme-containing aqueous suspensions to develop biosensors with improved performance.
Fu Y; Chen C; Xie Q; Xu X; Zou C; Zhou Q; Tan L; Tang H; Zhang Y; Yao S
Anal Chem; 2008 Aug; 80(15):5829-38. PubMed ID: 18593192
[TBL] [Abstract][Full Text] [Related]
6. A comparative study of enzyme immobilization strategies for multi-walled carbon nanotube glucose biosensors.
Shi J; Claussen JC; McLamore ES; ul Haque A; Jaroch D; Diggs AR; Calvo-Marzal P; Rickus JL; Porterfield DM
Nanotechnology; 2011 Sep; 22(35):355502. PubMed ID: 21828892
[TBL] [Abstract][Full Text] [Related]
7. Protein and polysaccharide-composite sol-gel silicate film for an interference-free amperometric glucose biosensor.
Matsuhisa H; Tsuchiya M; Hasebe Y
Colloids Surf B Biointerfaces; 2013 Nov; 111():523-9. PubMed ID: 23886787
[TBL] [Abstract][Full Text] [Related]
8. Glucose biosensor based on the immobilization of glucose oxidase on electrochemically synthesized polypyrrole-poly(vinyl sulphonate) composite film by cross-linking with glutaraldehyde.
Colak O; Yaşar A; Cete S; Arslan F
Artif Cells Blood Substit Immobil Biotechnol; 2012 Oct; 40(5):354-61. PubMed ID: 22540929
[TBL] [Abstract][Full Text] [Related]
9. A novel glucose biosensor based on immobilization of glucose oxidase into multiwall carbon nanotubes-polyelectrolyte-loaded electrospun nanofibrous membrane.
Manesh KM; Kim HT; Santhosh P; Gopalan AI; Lee KP
Biosens Bioelectron; 2008 Jan; 23(6):771-9. PubMed ID: 17905578
[TBL] [Abstract][Full Text] [Related]
10. Amperometric glucose biosensor based on glucose oxidase-lectin biospecific interaction.
Zhang J; Wang C; Chen S; Yuan D; Zhong X
Enzyme Microb Technol; 2013 Mar; 52(3):134-40. PubMed ID: 23410923
[TBL] [Abstract][Full Text] [Related]
11. Use of β-cyclodextrin as enhancer of ascorbic acid rejection in permselective films for amperometric biosensor applications.
Monti P; Rocchitta G; Marceddu S; Dettori MA; Fabbri D; Jaoua S; Migheli Q; Delogu G; Serra PA
Talanta; 2018 Aug; 186():53-59. PubMed ID: 29784398
[TBL] [Abstract][Full Text] [Related]
12. Highly sensitive glucose biosensor based on one-pot biochemical preoxidation and electropolymerization of 2,5-dimercapto-1,3,4-thiadiazole in glucose oxidase-containing aqueous suspension.
Fu Y; Zou C; Xie Q; Xu X; Chen C; Deng W; Yao S
J Phys Chem B; 2009 Feb; 113(5):1332-40. PubMed ID: 19138137
[TBL] [Abstract][Full Text] [Related]
13. A novel electrochemical glucose biosensor based on a poly (L-aspartic acid)-modified carbon-paste electrode.
Donmez S
Prep Biochem Biotechnol; 2020; 50(9):961-967. PubMed ID: 32779995
[TBL] [Abstract][Full Text] [Related]
14. Polypyrrole-glucose oxidase biosensor. Effect of enzyme encapsulation in multilamellar vesicles on analytical properties.
Olea D; Viratelle O; Faure C
Biosens Bioelectron; 2008 Jan; 23(6):788-94. PubMed ID: 17931850
[TBL] [Abstract][Full Text] [Related]
15. Amperometric hydrogen peroxide and glucose biosensor based on NiFe2/ordered mesoporous carbon nanocomposites.
Xiang D; Yin L; Ma J; Guo E; Li Q; Li Z; Liu K
Analyst; 2015 Jan; 140(2):644-53. PubMed ID: 25429370
[TBL] [Abstract][Full Text] [Related]
16. Fabrication of a promising immobilization platform based on electrochemical synthesis of a conjugated polymer.
Buber E; Soylemez S; Udum YA; Toppare L
Colloids Surf B Biointerfaces; 2018 Jul; 167():392-396. PubMed ID: 29702470
[TBL] [Abstract][Full Text] [Related]
17. Enzyme entrapment by β-cyclodextrin electropolymerization onto a carbon nanotubes-modified screen-printed electrode.
Alarcón-Ángeles G; Guix M; Silva WC; Ramírez-Silva MT; Palomar-Pardavé M; Romero-Romo M; Merkoçi A
Biosens Bioelectron; 2010 Dec; 26(4):1768-73. PubMed ID: 20863684
[TBL] [Abstract][Full Text] [Related]
18. A stable glucose biosensor prepared by co-immobilizing glucose oxidase into poly(p-chlorophenol) at a platinum electrode.
Xu JJ; Zhang XQ; Yu ZH; Fang HQ; Chen HY
Fresenius J Anal Chem; 2001 Mar; 369(6):486-90. PubMed ID: 11336332
[TBL] [Abstract][Full Text] [Related]
19. Characterization of Biosensors Based on Recombinant Glutamate Oxidase: Comparison of Crosslinking Agents in Terms of Enzyme Loading and Efficiency Parameters.
Ford R; Quinn SJ; O'Neill RD
Sensors (Basel); 2016 Sep; 16(10):. PubMed ID: 27669257
[TBL] [Abstract][Full Text] [Related]
20. Pt based enzyme electrode probes assembled with Prussian Blue and conducting polymer nanostructures.
Curulli A; Valentini F; Orlanduci S; Terranova ML; Palleschi G
Biosens Bioelectron; 2004 Dec; 20(6):1223-32. PubMed ID: 15556371
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]