BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

160 related articles for article (PubMed ID: 22163748)

  • 1. A non-invasive thermal drift compensation technique applied to a spin-valve magnetoresistive current sensor.
    Sánchez Moreno J; Ramírez Muñoz D; Cardoso S; Casans Berga S; Navarro Antón AE; Peixeiro de Freitas PJ
    Sensors (Basel); 2011; 11(3):2447-58. PubMed ID: 22163748
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Characterization of Magnetoresistive Shunts and Its Sensitivity Temperature Compensation.
    Ramírez-Muñoz D; García-Gil R; Cardoso S; Freitas P
    Sensors (Basel); 2024 May; 24(10):. PubMed ID: 38793901
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Temperature and Strain Compensation for Flexible Sensors Based on Thermosensation.
    Wang L; Zhu R; Li G
    ACS Appl Mater Interfaces; 2020 Jan; 12(1):1953-1961. PubMed ID: 31816229
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A localization method using 3-axis magnetoresistive sensors for tracking of capsule endoscope.
    Wang X; Meng MQ; Hu C
    Conf Proc IEEE Eng Med Biol Soc; 2006; 2006():2522-5. PubMed ID: 17946518
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A smart high accuracy silicon piezoresistive pressure sensor temperature compensation system.
    Zhou G; Zhao Y; Guo F; Xu W
    Sensors (Basel); 2014 Jul; 14(7):12174-90. PubMed ID: 25006998
    [TBL] [Abstract][Full Text] [Related]  

  • 6. High sensitivity detection of molecular recognition using magnetically labelled biomolecules and magnetoresistive sensors.
    Graham DL; Ferreira HA; Freitas PP; Cabral JM
    Biosens Bioelectron; 2003 Apr; 18(4):483-8. PubMed ID: 12604266
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Sensitive giant magnetoresistive-based immunoassay for multiplex mycotoxin detection.
    Mak AC; Osterfeld SJ; Yu H; Wang SX; Davis RW; Jejelowo OA; Pourmand N
    Biosens Bioelectron; 2010 Mar; 25(7):1635-9. PubMed ID: 20047828
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Tunnel Magnetoresistance Sensor with AC Modulation and Impedance Compensation for Ultra-Weak Magnetic Field Measurement.
    Zhao W; Tao X; Ye C; Tao Y
    Sensors (Basel); 2022 Jan; 22(3):. PubMed ID: 35161769
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Clusters of Spin Valve Sensors in 3D Magnetic Field of a Label.
    Babaytsev GV; Chechenin NG; Dzhun IO; Kozin MG; Makunin AV; Romashkina IL
    Sensors (Basel); 2021 May; 21(11):. PubMed ID: 34064169
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Magnetoresistive immunosensor for the detection of Escherichia coli O157:H7 including a microfluidic network.
    Mujika M; Arana S; Castaño E; Tijero M; Vilares R; Ruano-López JM; Cruz A; Sainz L; Berganza J
    Biosens Bioelectron; 2009 Jan; 24(5):1253-8. PubMed ID: 18760584
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Wheatstone bridge giant-magnetoresistance based cell counter.
    Lee CP; Lai MF; Huang HT; Lin CW; Wei ZH
    Biosens Bioelectron; 2014 Jul; 57():48-53. PubMed ID: 24534580
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Angular Position Sensor Based on Anisotropic Magnetoresistive and Anomalous Nernst Effect.
    Wang J; Xie H; Wu Y
    Sensors (Basel); 2024 Feb; 24(3):. PubMed ID: 38339727
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Bridge Resistance Compensation for Noise Reduction in a Self-Balanced PHMR Sensor.
    Lee J; Jeon C; Jeon T; Das PT; Lee Y; Lim B; Kim C
    Sensors (Basel); 2021 May; 21(11):. PubMed ID: 34064121
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Scanning probe microscopy based on magnetoresistive sensing.
    Sahoo DR; Sebastian A; Häberle W; Pozidis H; Eleftheriou E
    Nanotechnology; 2011 Apr; 22(14):145501. PubMed ID: 21346303
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Passive Resistor Temperature Compensation for a High-Temperature Piezoresistive Pressure Sensor.
    Yao Z; Liang T; Jia P; Hong Y; Qi L; Lei C; Zhang B; Li W; Zhang D; Xiong J
    Sensors (Basel); 2016 Jul; 16(7):. PubMed ID: 27455271
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Femtomolar limit of detection with a magnetoresistive biochip.
    Martins VC; Cardoso FA; Germano J; Cardoso S; Sousa L; Piedade M; Freitas PP; Fonseca LP
    Biosens Bioelectron; 2009 Apr; 24(8):2690-5. PubMed ID: 19261460
    [TBL] [Abstract][Full Text] [Related]  

  • 17. The compensation of perturbing temperature fluctuation in glucose monitoring technologies based on impedance spectroscopy.
    Huber D; Talary M; Dewarrat F; Caduff A
    Med Biol Eng Comput; 2007 Sep; 45(9):863-76. PubMed ID: 17661101
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A Magnetoresistive Tactile Sensor for Harsh Environment Applications.
    Alfadhel A; Khan MA; Cardoso S; Leitao D; Kosel J
    Sensors (Basel); 2016 May; 16(5):. PubMed ID: 27164113
    [TBL] [Abstract][Full Text] [Related]  

  • 19. The Effect of Geometrical Overlap between Giant Magnetoresistance Sensor and Magnetic Flux Concentrators: A Novel Comb-Shaped Sensor for Improved Sensitivity.
    Kulkarni PD; Iwasaki H; Nakatani T
    Sensors (Basel); 2022 Dec; 22(23):. PubMed ID: 36502082
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Serial MTJ-Based TMR Sensors in Bridge Configuration for Detection of Fractured Steel Bar in Magnetic Flux Leakage Testing.
    Jin Z; Mohd Noor Sam MAI; Oogane M; Ando Y
    Sensors (Basel); 2021 Jan; 21(2):. PubMed ID: 33477948
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.