BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

209 related articles for article (PubMed ID: 22163788)

  • 1. Optimization of sensing and feedback control for vibration/flutter of rotating disk by PZT actuators via air coupled pressure.
    Yan T; Xu X; Han J; Lin R; Ju B; Li Q
    Sensors (Basel); 2011; 11(3):3094-116. PubMed ID: 22163788
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Feasibility of using PZT actuators to study the dynamic behavior of a rotating disk due to rotor-stator interaction.
    Presas A; Egusquiza E; Valero C; Valentin D; Seidel U
    Sensors (Basel); 2014 Jul; 14(7):11919-42. PubMed ID: 25004151
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Vibration Excitation and Suppression of a Composite Laminate Plate Using Piezoelectric Actuators.
    Her SC; Chen HY
    Materials (Basel); 2022 Mar; 15(6):. PubMed ID: 35329480
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Smart Active Vibration Control System of a Rotary Structure Using Piezoelectric Materials.
    Hashemi A; Jang J; Hosseini-Hashemi S
    Sensors (Basel); 2022 Jul; 22(15):. PubMed ID: 35957246
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Active vibroacoustic control with multiple local feedback loops.
    Elliott SJ; Gardonio P; Sors TC; Brennan MJ
    J Acoust Soc Am; 2002 Feb; 111(2):908-15. PubMed ID: 11863192
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Thin-disk piezoceramic ultrasonic motor. Part I: design and performance evaluation.
    Wen FL; Yen CY; Ouyang M
    Ultrasonics; 2003 Aug; 41(6):437-50. PubMed ID: 12853080
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Performance Evaluation of a Piezoelectric Energy Harvester Based on Flag-Flutter.
    Elahi H; Eugeni M; Fune F; Lampani L; Mastroddi F; Paolo Romano G; Gaudenzi P
    Micromachines (Basel); 2020 Oct; 11(10):. PubMed ID: 33066434
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Polyvinylidene fluoride film sensors in collocated feedback structural control: application for suppressing impact-induced disturbances.
    Ma CC; Chuang KC; Pan SY
    IEEE Trans Ultrason Ferroelectr Freq Control; 2011 Dec; 58(12):2539-54. PubMed ID: 23443690
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Vibration analysis of composite laminate plate excited by piezoelectric actuators.
    Her SC; Lin CS
    Sensors (Basel); 2013 Mar; 13(3):2997-3013. PubMed ID: 23529121
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Self-sensing force control of a piezoelectric actuator.
    Badel A; Qiu J; Nakano T
    IEEE Trans Ultrason Ferroelectr Freq Control; 2008 Dec; 55(12):2571-81. PubMed ID: 19126482
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Real-Time Performance of Mechatronic PZT Module Using Active Vibration Feedback Control.
    Aggogeri F; Borboni A; Merlo A; Pellegrini N; Ricatto R
    Sensors (Basel); 2016 Sep; 16(10):. PubMed ID: 27681732
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Enhancement of optical adaptive sensing by using a dual-stage seesaw-swivel actuator with a tunable vibration absorber.
    Chou PC; Lin YC; Cheng S
    Sensors (Basel); 2011; 11(5):4808-29. PubMed ID: 22163877
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Design optimization of wide-band Tonpilz piezoelectric transducer with a bending piezoelectric disk on the radiation surface.
    Saijyou K; Okuyama T
    J Acoust Soc Am; 2010 May; 127(5):2836-46. PubMed ID: 21117734
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Lead-free piezoelectric-metal-cavity (PMC) actuators.
    Lam KH; Lin DM; Kwok KW; Lai-Wa Chan H
    IEEE Trans Ultrason Ferroelectr Freq Control; 2008 Aug; 55(8):1682-5. PubMed ID: 18986912
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Prestress Monitoring of a Steel Strand in an Anchorage Connection Using Piezoceramic Transducers and Time Reversal Method.
    Zhang X; Zhang L; Liu L; Huo L
    Sensors (Basel); 2018 Nov; 18(11):. PubMed ID: 30453673
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Active vibration control using an inertial actuator with internal damping.
    Paulitsch C; Gardonio P; Elliott SJ
    J Acoust Soc Am; 2006 Apr; 119(4):2131-40. PubMed ID: 16642828
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Coupling analysis of a matched piezoelectric sensor and actuator pair for vibration control of a smart beam.
    Lee YS; Gardonio P; Elliott SJ
    J Acoust Soc Am; 2002 Jun; 111(6):2715-26. PubMed ID: 12083206
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Prototyping a compact system for active vibration isolation using piezoelectric sensors and actuators.
    Shen H; Wang C; Li L; Chen L
    Rev Sci Instrum; 2013 May; 84(5):055002. PubMed ID: 23742582
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Fabrication of piezoelectric ceramic micro-actuator and its reliability for hard disk drives.
    Jing Y; Luo J; Yang W; Ju G
    IEEE Trans Ultrason Ferroelectr Freq Control; 2004 Nov; 51(11):1470-6. PubMed ID: 15600092
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Tension Monitoring of Wedge Connection Using Piezoceramic Transducers and Wavelet Packet Analysis Method.
    Zhang X; Zhang L; Liu L; Huo L
    Sensors (Basel); 2020 Jan; 20(2):. PubMed ID: 31936421
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.