BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

137 related articles for article (PubMed ID: 22165753)

  • 1. [High, open wedge tibial osteotomy: finite element analysis of five internal fixation modalities].
    Stepanović Z; Zivković M; Vulović S; Aćimović L; Ristić B; Matić A; Grujović Z
    Vojnosanit Pregl; 2011 Oct; 68(10):867-71. PubMed ID: 22165753
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Role of an anatomically contoured plate and metal block for balanced stability between the implant and lateral hinge in open-wedge high-tibial osteotomy.
    Jang YW; Lim D; Seo H; Lee MC; Lee OS; Lee YS
    Arch Orthop Trauma Surg; 2018 Jul; 138(7):911-920. PubMed ID: 29546620
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [Opening-wedge osteotomy of the proximal tibia].
    Prix R
    Acta Chir Orthop Traumatol Cech; 2005; 72(5):308-12. PubMed ID: 16316607
    [TBL] [Abstract][Full Text] [Related]  

  • 4. The short-term follow-up results of open wedge high tibial osteotomy with using an Aescula open wedge plate and an allogenic bone graft: the minimum 1-year follow-up results.
    Lee SC; Jung KA; Nam CH; Jung SH; Hwang SH
    Clin Orthop Surg; 2010 Mar; 2(1):47-54. PubMed ID: 20191001
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Medial opening-wedge high tibial valgus osteotomy, using a stable TomoFix plate, in genu varum arthritis: surgical technique].
    Horácek D; Cech O; Weissinger M
    Acta Chir Orthop Traumatol Cech; 2006 Jun; 73(3):197-204. PubMed ID: 16846566
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A new fixation material for open-wedge tibial osteotomy for genu varum.
    Ribeiro CH; Severino NR; Cury Rde P; de Oliveira VM; Avakian R; Ayhara T; de Camargo OP
    Knee; 2009 Oct; 16(5):366-70. PubMed ID: 19249213
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Finite element analysis of Puddu and Tomofix plate fixation for open wedge high tibial osteotomy.
    Raja Izaham RM; Abdul Kadir MR; Abdul Rashid AH; Hossain MG; Kamarul T
    Injury; 2012 Jun; 43(6):898-902. PubMed ID: 22204773
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [Proximal tibial osteotomy for osteoarthritis of the knee with varus deformity].
    Baur W; Hönle W; Schuh A
    Oper Orthop Traumatol; 2005 Sep; 17(3):326-44. PubMed ID: 16132254
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Biomechanical evaluation of combined proximal tibial osteotomy for varus knee osteoarthritis implanted novel designed plate system: Finite element analysis.
    Zhao G; Li D; Ji W; Luo C
    Injury; 2022 Jul; 53(7):2416-2423. PubMed ID: 35618538
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Biomechanical investigation of different internal fixations in medial opening-wedge high tibial osteotomy.
    Spahn G; Mückley T; Kahl E; Hofmann GO
    Clin Biomech (Bristol, Avon); 2006 Mar; 21(3):272-8. PubMed ID: 16337721
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Loss of correction after medial opening wedge high tibial osteotomy: a comparison of locking plates without bone grafts and non-locking compression plates with bone grafts.
    Pornrattanamaneewong C; Harnroongroj T; Chareancholvanich K
    J Med Assoc Thai; 2012 Sep; 95 Suppl 9():S21-8. PubMed ID: 23326978
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Biplanar Open Wedge High Tibial Osteotomy in the Medial Compartment Osteoarthritis of the Knee Joint: Comparison between the Aescula and TomoFix Plate.
    Kyung HS; Lee BJ; Kim JW; Yoon SD
    Clin Orthop Surg; 2015 Jun; 7(2):185-90. PubMed ID: 26217464
    [TBL] [Abstract][Full Text] [Related]  

  • 13. How plate positioning impacts the biomechanics of the open wedge tibial osteotomy; a finite element analysis.
    Blecha LD; Zambelli PY; Ramaniraka NA; Bourban PE; Månson JA; Pioletti DP
    Comput Methods Biomech Biomed Engin; 2005 Oct; 8(5):307-13. PubMed ID: 16298852
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Biomechanical investigation of the type and configuration of screws used in high tibial osteotomy with titanium locking plate and screw fixation.
    Chen YN; Chang CW; Li CT; Chen CH; Chung CR; Chang CH; Peng YT
    J Orthop Surg Res; 2019 Jan; 14(1):35. PubMed ID: 30691494
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Combined proximal tibial osteotomy for varus osteoarthritis of the knee: Biomechanical tests and finite-element analyses.
    Ji W; Luo C; Zhan S; Zhan Y; Xie X; Zhang B
    Knee; 2020 Jun; 27(3):863-870. PubMed ID: 32046900
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Biomechanical evaluation of opening-wedge high tibial osteotomy with composite materials using finite-element analysis.
    Koh YG; Son J; Kwon SK; Kim HJ; Kang KT
    Knee; 2018 Dec; 25(6):977-987. PubMed ID: 30446348
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Biomechanical effects of plate area and locking screw on medial open tibial osteotomy.
    Luo CA; Lin SC; Hwa SY; Chen CM; Tseng CS
    Comput Methods Biomech Biomed Engin; 2015; 18(12):1263-71. PubMed ID: 24617553
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Accuracy of high tibial osteotomy: comparison between open- and closed-wedge technique.
    Hankemeier S; Mommsen P; Krettek C; Jagodzinski M; Brand J; Meyer C; Meller R
    Knee Surg Sports Traumatol Arthrosc; 2010 Oct; 18(10):1328-33. PubMed ID: 20033672
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Which osteotomy for a valgus knee?
    Puddu G; Cipolla M; Cerullo G; Franco V; Giannì E
    Int Orthop; 2010 Feb; 34(2):239-47. PubMed ID: 19547972
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Comparison of theoretical fixation stability of three devices employed in medial opening wedge high tibial osteotomy: a finite element analysis.
    Golovakhа ML; Orljanski W; Benedetto KP; Panchenko S; Büchler P; Henle P; Aghayev E
    BMC Musculoskelet Disord; 2014 Jul; 15():230. PubMed ID: 25012591
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.