BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

1276 related articles for article (PubMed ID: 22166358)

  • 1. Clinical value of intraoperative neuromonitoring of the recurrent laryngeal nerves in improving outcomes of surgery for well-differentiated thyroid cancer.
    Barczyński M; Konturek A; Stopa M; Hubalewska-Dydejczyk A; Richter P; Nowak W
    Pol Przegl Chir; 2011 Apr; 83(4):196-203. PubMed ID: 22166358
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Double probe intraoperative neuromonitoring with a standardized method in thyroid surgery.
    De Falco M; Santangelo G; Del Giudice S; Gallucci F; Parmeggiani U
    Int J Surg; 2014; 12 Suppl 1():S140-4. PubMed ID: 24862671
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Stimulating dissecting instruments during neuromonitoring of RLN in thyroid surgery.
    Chiang FY; Lu IC; Chang PY; Sun H; Wang P; Lu XB; Chen HC; Chen HY; Kim HY; Dionigi G; Wu CW
    Laryngoscope; 2015 Dec; 125(12):2832-7. PubMed ID: 25809677
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Recurrent laryngeal nerve management in thyroid surgery: consequences of routine visualization, application of intermittent, standardized and continuous nerve monitoring.
    Anuwong A; Lavazza M; Kim HY; Wu CW; Rausei S; Pappalardo V; Ferrari CC; Inversini D; Leotta A; Biondi A; Chiang FY; Dionigi G
    Updates Surg; 2016 Dec; 68(4):331-341. PubMed ID: 27651334
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A functional assessment of anatomical variants of the recurrent laryngeal nerve during thyroidectomies using neuromonitoring.
    Wojtczak B; Kaliszewski K; Sutkowski K; Bolanowski M; Barczyński M
    Endocrine; 2018 Jan; 59(1):82-89. PubMed ID: 29119329
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Systematic review with meta-analysis of studies comparing intraoperative neuromonitoring of recurrent laryngeal nerves versus visualization alone during thyroidectomy.
    Pisanu A; Porceddu G; Podda M; Cois A; Uccheddu A
    J Surg Res; 2014 May; 188(1):152-61. PubMed ID: 24433869
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Routine Intraoperative Neuromonitoring of the Recurrent Laryngeal Nerve to Facilitate Complete Resection and Ensure Safety in Thyroid Cancer Surgery.
    Wu SY; Shen HY; Duh QY; Hsieh CB; Yu JC; Shih ML
    Am Surg; 2018 Dec; 84(12):1882-1888. PubMed ID: 30606343
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The Overwhelming Majority but not All Motor Fibers of the Bifid Recurrent Laryngeal Nerve are Located in the Anterior Extralaryngeal Branch.
    Barczyński M; Stopa M; Konturek A; Nowak W
    World J Surg; 2016 Mar; 40(3):629-35. PubMed ID: 26438241
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Association of Intraoperative Neuromonitoring With Reduced Recurrent Laryngeal Nerve Injury in Patients Undergoing Total Thyroidectomy.
    Vasileiadis I; Karatzas T; Charitoudis G; Karakostas E; Tseleni-Balafouta S; Kouraklis G
    JAMA Otolaryngol Head Neck Surg; 2016 Oct; 142(10):994-1001. PubMed ID: 27490310
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Thyroid reoperation using intraoperative neuromonitoring.
    Wojtczak B; Sutkowski K; Kaliszewski K; Barczyński M; Bolanowski M
    Endocrine; 2017 Dec; 58(3):458-466. PubMed ID: 29052179
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Varied Recurrent Laryngeal Nerve Course Is Associated with Increased Risk of Nerve Dysfunction During Thyroidectomy: Results of the Surgical Anatomy of the Recurrent Laryngeal Nerve in Thyroid Surgery Study, an International Multicenter Prospective Anatomic and Electrophysiologic Study of 1000 Monitored Nerves at Risk from the International Neural Monitoring Study Group.
    Liddy W; Wu CW; Dionigi G; Donatini G; Giles Senyurek Y; Kamani D; Iwata A; Wang B; Okose O; Cheung A; Saito Y; Casella C; Aygun N; Uludag M; Brauckhoff K; Carnaille B; Tunca F; Barczyński M; Kim HY; Favero E; Innaro N; Vamvakidis K; Serpell J; Romanchishen AF; Takami H; Chiang FY; Schneider R; Dralle H; Shin JJ; Abdelhamid Ahmed AH; Randolph GW
    Thyroid; 2021 Nov; 31(11):1730-1740. PubMed ID: 34541890
    [No Abstract]   [Full Text] [Related]  

  • 12. Prospective evaluation of the utility of routine neuromonitoring for an established thyroid surgical practice.
    Lee J; Fraser S; Glover A; Sidhu S
    ANZ J Surg; 2017 Oct; 87(10):E138-E142. PubMed ID: 27091372
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Experience with intraoperative neuromonitoring of the recurrent laryngeal nerve improves surgical skills and outcomes of non-monitored thyroidectomy.
    Wojtczak B; Sutkowski K; Kaliszewski K; Głód M; Barczyński M
    Langenbecks Arch Surg; 2017 Jun; 402(4):709-717. PubMed ID: 27209315
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Evaluation of implementation phase of intraoperative neural monitoring of the recurrent laryngeal nerves in thyroid surgery in a district hospital].
    Pragacz K; Barczyński M
    Przegl Lek; 2014; 71(10):532-6. PubMed ID: 25826976
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Intraoperative nerve monitoring can reduce prevalence of recurrent laryngeal nerve injury in thyroid reoperations: results of a retrospective cohort study.
    Barczyński M; Konturek A; Pragacz K; Papier A; Stopa M; Nowak W
    World J Surg; 2014 Mar; 38(3):599-606. PubMed ID: 24081538
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Intraoperative intermittent neuromonitoring of inferior laryngeal nerve and staged thyroidectomy: our experience.
    Cavicchi O; Burgio L; Cioccoloni E; Piccin O; Macrì G; Schiavon P; Dionigi G
    Endocrine; 2018 Dec; 62(3):560-565. PubMed ID: 30173330
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Modification of the Surgical Strategy for the Dissection of the Recurrent Laryngeal Nerve Using Continuous Intraoperative Nerve Monitoring.
    Marin Arteaga A; Peloni G; Leuchter I; Bedat B; Karenovics W; Triponez F; Sadowski SM
    World J Surg; 2018 Feb; 42(2):444-450. PubMed ID: 28986621
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Does extensive dissection of recurrent laryngeal nerve during thyroid operation increase the risk of nerve injury? Evidence from the application of intraoperative neuromonitoring.
    Chiang FY; Lu IC; Tsai CJ; Hsiao PJ; Hsu CC; Wu CW
    Am J Otolaryngol; 2011; 32(6):499-503. PubMed ID: 21306792
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Feasibility and Effectiveness of Intraoperative Nerve Monitoring in Total Endoscopic Thyroidectomy for Thyroid Cancer.
    Xie Q; Wang P; Yan H; Wang Y
    J Laparoendosc Adv Surg Tech A; 2016 Feb; 26(2):109-15. PubMed ID: 26690784
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Prognostic value of intraoperative neural monitoring of the recurrent laryngeal nerve in thyroid surgery.
    Stopa M; Barczyński M
    Langenbecks Arch Surg; 2017 Sep; 402(6):957-964. PubMed ID: 27143020
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 64.