These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

167 related articles for article (PubMed ID: 22169664)

  • 1. The femoral-based endowedge technique to increase juxtarenal seal and correct graft tilt.
    Minion DJ; Xenos ES
    J Vasc Surg; 2012 May; 55(5):1522-5. PubMed ID: 22169664
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The endowedge and kilt techniques to achieve additional juxtarenal seal during deployment of the Gore Excluder endoprosthesis.
    Minion DJ; Yancey A; Patterson DE; Saha S; Endean ED
    Ann Vasc Surg; 2006 Jul; 20(4):472-7. PubMed ID: 16791453
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Juxtarenal Inflammatory Aneurysm Treated with Bilateral Iliac-Renal Bypass Using the Gore Hybrid Device and Total Sealing of the Aneurysmal Sac with a Nellix Device.
    Martinelli O; Malaj A; Gattuso R; Irace L; Gossetti B
    Ann Vasc Surg; 2017 Jan; 38():321.e13-321.e18. PubMed ID: 27666797
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Bailout Chimney Technique during Endovascular Aneurysm Sealing for Accidental Renal Artery Coverage.
    Varetto G; Castagno C; Quaglino S; Garneri P; Trevisan A; Destro M; Rossato D; Rispoli P
    J Vasc Interv Radiol; 2016 Nov; 27(11):1710-1712. PubMed ID: 27926390
    [No Abstract]   [Full Text] [Related]  

  • 5. New results with 100 Excluder cases.
    Ghotbi R; Sotiriou A; Mansur R
    J Cardiovasc Surg (Torino); 2010 Aug; 51(4):475-80. PubMed ID: 20671631
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Endovascular aortic repair with the chimney technique using the ultra low-profile Ovation stent-graft for juxtarenal aneurysms having small iliac access vessels.
    Massmann A; Serracino-Inglott F; Buecker A
    Cardiovasc Intervent Radiol; 2014 Apr; 37(2):488-92. PubMed ID: 24091760
    [TBL] [Abstract][Full Text] [Related]  

  • 7. The "open" chimney graft technique for juxtarenal aortic aneurysms with discrepant renal arteries.
    Ducasse E; Lepidi S; Brochier C; Deglise S; Berard X; Alberti D; Midy D
    Eur J Vasc Endovasc Surg; 2014 Feb; 47(2):124-30. PubMed ID: 24309400
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The chimney graft technique for preserving renal arteries in stent-graft sealing zones.
    Moulakakis KG; Papapetrou A; Giannakopoulos TG; Avgerinos ED; Kakisis J; Brountzos EN; Liapis CD
    Vasa; 2012 Jul; 41(4):295-300. PubMed ID: 22825865
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Physician-Modified C3 Excluder Endograft as the Preferred Solution to Treat a Juxtarenal Para-Anastomotic Aneurysm.
    Couture T; Coscas R; Lamas H; Mlynski A; Javerliat I; Goeau-Brissonniere O; Coggia M
    Ann Vasc Surg; 2017 Feb; 39():287.e1-287.e5. PubMed ID: 27890845
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Chimney stents for endovascular repair of juxtarenal aortic aneurysms with unfavourable anatomy.
    Liu B; Pan H; Song X; Liu C; Wu W; Chen Y; Yang X
    Int Angiol; 2013 Jun; 32(3):307-11. PubMed ID: 23711682
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A multicenter, randomized, controlled trial of totally percutaneous access versus open femoral exposure for endovascular aortic aneurysm repair (the PEVAR trial).
    Nelson PR; Kracjer Z; Kansal N; Rao V; Bianchi C; Hashemi H; Jones P; Bacharach JM
    J Vasc Surg; 2014 May; 59(5):1181-93. PubMed ID: 24440678
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Technical tips for endovascular treatment of abdominal aortic aneurysms with challenging infrarenal neck anatomy using the Excluder endoprosthesis.
    Ghouri MA; Dougherty KG; Krajcer Z
    J Endovasc Ther; 2010 Dec; 17(6):705-11. PubMed ID: 21142477
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A modified technique for Gore Excluder limb deployment in difficult iliac anatomy during endovascular abdominal aortic aneurysm repair.
    Vourliotakis G; Katsargyris Α; Tielliu IF; Zeebregts CJ; Verhoeven EL
    Vascular; 2015 Feb; 23(1):78-82. PubMed ID: 24668057
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Zenith p-branch standard fenestrated endovascular graft for juxtarenal abdominal aortic aneurysms.
    Kitagawa A; Greenberg RK; Eagleton MJ; Mastracci TM
    J Vasc Surg; 2013 Aug; 58(2):291-300. PubMed ID: 23611709
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Partial distal deployment for precise placement of the GORE Thoracic Endoprosthesis.
    Stanley GA
    J Vasc Surg; 2017 Aug; 66(2):661-665. PubMed ID: 28583736
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Late Gore Excluder endoprosthesis fabric tear leading to abdominal aortic aneurysm rupture 5 years after initial implant.
    Dayama A; Tsilimparis N; Kasirajan K; Reeves JG
    J Vasc Surg; 2013 Jan; 57(1):221-4. PubMed ID: 23141682
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Innovative chimney-graft technique for endovascular repair of a pararenal abdominal aortic aneurysm.
    Galiñanes EL; Hernandez-Vila EA; Krajcer Z
    Tex Heart Inst J; 2015 Feb; 42(1):35-9. PubMed ID: 25873796
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Physician modification of Gore C3 excluder endograft for treatment of abdominal aortic aneurysms anatomically unsuitable for conventional endovascular repair.
    Coulter AH; Tan TW; Zhang WW
    J Vasc Surg; 2014 Jun; 59(6):1739-43. PubMed ID: 24440676
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Incomplete Excluder limb graft deployment: cause and solution.
    Klonaris C; Katsargyris A; Koutsoumpelis A; Kouvelos G; Georgopoulos S
    Ann Vasc Surg; 2014 Jan; 28(1):263.e7-10. PubMed ID: 24200146
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Physician-Modified Endovascular Gore Excluder Graft (Handmade Modified) for Complex Abdominal Aortic Aneurysm: A Step-by-Step Approach.
    Lopez-Pena G; Garcia-Alva R; Laparra-Escareno H; Anaya-Ayala JE; Guerrero-Hernández M; Hinojosa CA
    Vasc Endovascular Surg; 2020 Oct; 54(7):656-659. PubMed ID: 32643587
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.