These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

230 related articles for article (PubMed ID: 22179979)

  • 21. Association between dislocation, impingement, and articular geometry in retrieved acetabular polyethylene cups.
    Tanino H; Harman MK; Banks SA; Hodge WA
    J Orthop Res; 2007 Nov; 25(11):1401-7. PubMed ID: 17471491
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Otto Aufranc Award: Crosslinking Reduces THA Wear, Osteolysis, and Revision Rates at 15-year Followup Compared With Noncrosslinked Polyethylene.
    Hopper RH; Ho H; Sritulanondha S; Williams AC; Engh CA
    Clin Orthop Relat Res; 2018 Feb; 476(2):279-290. PubMed ID: 29529656
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Association of third body embedment with rim damage in retrieved acetabular liners.
    Lundberg HJ; Liu SS; Callaghan JJ; Pedersen DR; O'Rourke MR; Goetz DD; Vittetoe DA; Clohisy JC; Brown TD
    Clin Orthop Relat Res; 2007 Dec; 465():133-9. PubMed ID: 18090471
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Excessive polyethylene wear and acetabular bone defects from standard use of a hooded acetabular insert in total hip arthroplasty.
    Gerhardt DM; Sanders RJ; de Visser E; van Susante JL
    Int Orthop; 2014 Aug; 38(8):1585-90. PubMed ID: 24695978
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Long-Term Outcomes of Constrained Liners Cemented into Retained, Well-Fixed Acetabular Components.
    Brown TS; Tibbo ME; Arsoy D; Lewallen DG; Hanssen AD; Trousdale RT; Abdel MP
    J Bone Joint Surg Am; 2019 Apr; 101(7):620-627. PubMed ID: 30946196
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Dual mobility cups provide biomechanical advantages in situations at risk for dislocation: a finite element analysis.
    Terrier A; Latypova A; Guillemin M; Parvex V; Guyen O
    Int Orthop; 2017 Mar; 41(3):551-556. PubMed ID: 28070611
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Current Total Knee Designs: Does Baseplate Roughness or Locking Mechanism Design Affect Polyethylene Backside Wear?
    Sisko ZW; Teeter MG; Lanting BA; Howard JL; McCalden RW; Naudie DD; MacDonald SJ; Vasarhelyi EM
    Clin Orthop Relat Res; 2017 Dec; 475(12):2970-2980. PubMed ID: 28905208
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Retrieval analysis of Harris-Galante I and II acetabular liners in situ for more than 10 years.
    French K; Moore R; Gawel H; Kurtz SM; Kraay MJ; Xie K; Goldberg VM; Rimnac CM
    Acta Orthop; 2012 Aug; 83(4):366-73. PubMed ID: 22880709
    [TBL] [Abstract][Full Text] [Related]  

  • 29. A Retrieval Analysis of Impingement in Dual-Mobility Liners.
    Scott TP; Weitzler L; Salvatore A; Wright TM; Westrich GH
    J Arthroplasty; 2018 Aug; 33(8):2660-2665. PubMed ID: 29661526
    [TBL] [Abstract][Full Text] [Related]  

  • 30. [Wear and Roughness of Bearing Surface in Retrieved Polyethylene Bicon-Plus Cups].
    Ranuša M; Gallo J; Hobza M; Vrbka M; Nečas D; Hartl M
    Acta Chir Orthop Traumatol Cech; 2017; 84(3):159-167. PubMed ID: 28809634
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Tantalum Components in Difficult Acetabular Revisions Have Good Survival at 5 to 10 Years: Longer Term Followup of a Previous Report.
    Lachiewicz PF; O'Dell JA
    Clin Orthop Relat Res; 2018 Feb; 476(2):336-342. PubMed ID: 29529665
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Cementless Total Hip Arthroplasty With Metasul Bearings Provides Good Results in Active Young Patients: A Concise Followup.
    Delaunay CP; Putman S; Puliéro B; Bégin M; Migaud H; Bonnomet F
    Clin Orthop Relat Res; 2016 Oct; 474(10):2126-33. PubMed ID: 27278679
    [TBL] [Abstract][Full Text] [Related]  

  • 33. LUMiC
    Bus MP; Szafranski A; Sellevold S; Goryn T; Jutte PC; Bramer JA; Fiocco M; Streitbürger A; Kotrych D; van de Sande MA; Dijkstra PD
    Clin Orthop Relat Res; 2017 Mar; 475(3):686-695. PubMed ID: 27020434
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Intra-prosthetic dislocation of dual-mobility cups after total hip arthroplasty: potential causes from a clinical and biomechanical perspective.
    Fabry C; Langlois J; Hamadouche M; Bader R
    Int Orthop; 2016 May; 40(5):901-6. PubMed ID: 26429197
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Do alumina matrix composite bearings decrease hip noises and bearing fractures at a minimum of 5 years after THA?
    Baek SH; Kim WK; Kim JY; Kim SY
    Clin Orthop Relat Res; 2015 Dec; 473(12):3796-802. PubMed ID: 26126991
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Is There a Difference in Revision Risk Between Metal and Ceramic Heads on Highly Crosslinked Polyethylene Liners?
    Cafri G; Paxton EW; Love R; Bini SA; Kurtz SM
    Clin Orthop Relat Res; 2017 May; 475(5):1349-1355. PubMed ID: 27385222
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Acetabular liner with focal constraint to prevent dislocation after THA.
    Munro JT; Vioreanu MH; Masri BA; Duncan CP
    Clin Orthop Relat Res; 2013 Dec; 471(12):3883-90. PubMed ID: 23423623
    [TBL] [Abstract][Full Text] [Related]  

  • 38. [Research progress of backside wear in acetabular liners].
    Zhou K; Li S; Yang C; Qi X
    Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2013 Dec; 27(12):1453-6. PubMed ID: 24640364
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Prevention of dislocation in total hip revision surgery using a dual mobility design.
    Philippot R; Adam P; Reckhaus M; Delangle F; Verdot F-; Curvale G; Farizon F
    Orthop Traumatol Surg Res; 2009 Oct; 95(6):407-13. PubMed ID: 19656750
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Standard, Large-Head, Dual-Mobility, or Constrained-Liner Revision Total Hip Arthroplasty for a Diagnosis of Dislocation: An Analysis of 1,275 Revision Total Hip Replacements.
    Hoskins W; Bingham R; Hatton A; de Steiger RN
    J Bone Joint Surg Am; 2020 Dec; 102(23):2060-2067. PubMed ID: 33264216
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 12.