These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
233 related articles for article (PubMed ID: 22180216)
41. Comparison of retrospectively self-gated and prospectively triggered FLASH sequences for cine imaging of the aorta in mice at 9.4 Tesla. Fries P; Massmann A; Seidel R; Müller A; Stroeder J; Custodis F; Reil J; Schneider G; Buecker A Invest Radiol; 2012 Apr; 47(4):259-66. PubMed ID: 22373534 [TBL] [Abstract][Full Text] [Related]
42. [Comparison between fast MR flow quantification in breathhold technique in ascending aorta and pulmonary trunc with right and left ventricular cine-MRI for the assessment of stroke volumes in healthy volunteers]. Rominger MB; Dinkel HP; Bachmann GF Rofo; 2002 Feb; 174(2):196-201. PubMed ID: 11898082 [TBL] [Abstract][Full Text] [Related]
43. Visualization of hemodynamics in intracranial arteries using time-resolved three-dimensional phase-contrast MRI. Yamashita S; Isoda H; Hirano M; Takeda H; Inagawa S; Takehara Y; Alley MT; Markl M; Pelc NJ; Sakahara H J Magn Reson Imaging; 2007 Mar; 25(3):473-8. PubMed ID: 17279504 [TBL] [Abstract][Full Text] [Related]
44. Spiral phase velocity mapping of left and right coronary artery blood flow: correction for through-plane motion using selective fat-only excitation. Keegan J; Gatehouse PD; Yang GZ; Firmin DN J Magn Reson Imaging; 2004 Dec; 20(6):953-60. PubMed ID: 15558551 [TBL] [Abstract][Full Text] [Related]
45. Balanced phase-contrast steady-state free precession (PC-SSFP): a novel technique for velocity encoding by gradient inversion. Markl M; Alley MT; Pelc NJ Magn Reson Med; 2003 May; 49(5):945-52. PubMed ID: 12704778 [TBL] [Abstract][Full Text] [Related]
46. Cine flow measurements using phase contrast with undersampled projections: in vitro validation and preliminary results in vivo. Wentland AL; Korosec FR; Vigen KK; Wieben O; Fine JP; Grist TM J Magn Reson Imaging; 2006 Oct; 24(4):945-51. PubMed ID: 16969791 [TBL] [Abstract][Full Text] [Related]
47. In vivo quantification of helical blood flow in human aorta by time-resolved three-dimensional cine phase contrast magnetic resonance imaging. Morbiducci U; Ponzini R; Rizzo G; Cadioli M; Esposito A; De Cobelli F; Del Maschio A; Montevecchi FM; Redaelli A Ann Biomed Eng; 2009 Mar; 37(3):516-31. PubMed ID: 19142728 [TBL] [Abstract][Full Text] [Related]
48. Real-time cardiovascular magnetic resonance at high temporal resolution: radial FLASH with nonlinear inverse reconstruction. Zhang S; Uecker M; Voit D; Merboldt KD; Frahm J J Cardiovasc Magn Reson; 2010 Jul; 12(1):39. PubMed ID: 20615228 [TBL] [Abstract][Full Text] [Related]
50. Flow quantitation with echo-planar phase-contrast velocity mapping: in vitro and in vivo evaluation. Debatin JF; Leung DA; Wildermuth S; Botnar R; Felblinger J; McKinnon GC J Magn Reson Imaging; 1995; 5(6):656-62. PubMed ID: 8748482 [TBL] [Abstract][Full Text] [Related]
51. Carotid blood flow measurement accelerated by compressed sensing: validation in healthy volunteers. Tao Y; Rilling G; Davies M; Marshall I Magn Reson Imaging; 2013 Nov; 31(9):1485-91. PubMed ID: 23830111 [TBL] [Abstract][Full Text] [Related]
52. Undersampled radial MRI with multiple coils. Iterative image reconstruction using a total variation constraint. Block KT; Uecker M; Frahm J Magn Reson Med; 2007 Jun; 57(6):1086-98. PubMed ID: 17534903 [TBL] [Abstract][Full Text] [Related]
53. MRI quantification of the role of the reflected pressure wave on coronary and ascending aortic blood flow. Laffon E; Galy-Lacour C; Laurent F; Ducassou D; Marthan R Physiol Meas; 2003 Aug; 24(3):681-92. PubMed ID: 14509306 [TBL] [Abstract][Full Text] [Related]