These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

108 related articles for article (PubMed ID: 22182224)

  • 21. Retrospective evaluation of complete-arch fixed partial dentures connecting teeth and implant abutments in patients with normal and reduced periodontal support.
    Cordaro L; Ercoli C; Rossini C; Torsello F; Feng C
    J Prosthet Dent; 2005 Oct; 94(4):313-20. PubMed ID: 16198167
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Fracture Strength of Composite Rest Seats: An In Vitro Comparative Study of Different Composite versus Amalgam Restorations.
    Fouda SM; Ellakany P; Gad MM; Bahgat HA; Ayad NM; Ateeq IS; Dehailan LA; Mahrous AA
    Materials (Basel); 2023 Jul; 16(13):. PubMed ID: 37445144
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Periodontal Conditions of Abutments and Non-Abutments in Removable Partial Dentures over 7 Years of Use.
    da Fonte Porto Carreiro A; de Carvalho Dias K; Correia Lopes AL; Bastos Machado Resende CM; Luz de Aquino Martins AR
    J Prosthodont; 2017 Dec; 26(8):644-649. PubMed ID: 26864601
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Effect of implant support on distal-extension removable partial dentures: in vivo assessment.
    Ohkubo C; Kobayashi M; Suzuki Y; Hosoi T
    Int J Oral Maxillofac Implants; 2008; 23(6):1095-101. PubMed ID: 19216279
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Support of undermined occlusal enamel provided by restorative materials.
    Latino C; Troendle K; Summitt JB
    Quintessence Int; 2001 Apr; 32(4):287-91. PubMed ID: 12066648
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Comparisons of tactile thresholds between implant-supported fixed partial dentures and removable partial dentures.
    Garrett NR; Hasse AL; Kapur KK
    Int J Prosthodont; 1992; 5(6):515-22. PubMed ID: 1307010
    [TBL] [Abstract][Full Text] [Related]  

  • 27. [Modifications of occlusal and axial morphology in removable partial denture].
    Borel JC; Mussier J
    Rev Odontostomatol (Paris); 1989; 18(1):69-74. PubMed ID: 2699060
    [TBL] [Abstract][Full Text] [Related]  

  • 28. The use of ceramic orthodontic brackets as rest seats for removable partial dentures.
    Counts AL; Hopkins AR
    J Prosthodont; 1995 Mar; 4(1):3. PubMed ID: 7670609
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Abutment tooth modification for removable partial denture therapy.
    Wright WE
    Compendium; 1989 Jan; 10(1):40-3, 46-7. PubMed ID: 2688890
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Wear evaluation of porcelain opposing gold, composite resin, and enamel.
    Kadokawa A; Suzuki S; Tanaka T
    J Prosthet Dent; 2006 Oct; 96(4):258-65. PubMed ID: 17052470
    [TBL] [Abstract][Full Text] [Related]  

  • 31. The use of composite resin in removable prosthodontics.
    Garcia LT; Bohnenkamp DM
    Compend Contin Educ Dent; 2003 Sep; 24(9):688-90, 692, 694 passim. PubMed ID: 14596209
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Clinical evaluation of direct cuspal coverage with posterior composite resin restorations.
    Deliperi S; Bardwell DN
    J Esthet Restor Dent; 2006; 18(5):256-65; discussion 266-7. PubMed ID: 16987320
    [TBL] [Abstract][Full Text] [Related]  

  • 33. The construction of crowns for removable partial denture abutment teeth.
    Burns DR; Unger JW
    Quintessence Int; 1994 Jul; 25(7):471-5. PubMed ID: 7991768
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Effect of laser pretreated enamel and dentin of primary teeth on microleakage of different restorative materials.
    Salama FS
    J Clin Pediatr Dent; 1998; 22(4):285-91. PubMed ID: 9796497
    [TBL] [Abstract][Full Text] [Related]  

  • 35. A clinical investigation of the fit of removable partial dental prosthesis clasp assemblies.
    Dunham D; Brudvik JS; Morris WJ; Plummer KD; Cameron SM
    J Prosthet Dent; 2006 Apr; 95(4):323-6. PubMed ID: 16616131
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Abutment preparation modifications for removable partial denture rest seats.
    Wiebelt FJ; Shillingburg HT
    Quintessence Dent Technol; 1985; 9(7):449-51. PubMed ID: 3898234
    [No Abstract]   [Full Text] [Related]  

  • 37. Abutment load transfer by removable partial denture obturator frameworks in different acquired maxillary defects.
    Lyons KM; Beumer J; Caputo AA
    J Prosthet Dent; 2005 Sep; 94(3):281-8. PubMed ID: 16126081
    [TBL] [Abstract][Full Text] [Related]  

  • 38. A retrospective clinical study of resin-bonded cingulum rest seats.
    Janus CE; Unger JW; Crabtree DG; McCasland JP
    J Prosthodont; 1996 Jun; 5(2):91-4. PubMed ID: 9028210
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Quality of removable partial dentures worn by the adult U.S. population.
    Hummel SK; Wilson MA; Marker VA; Nunn ME
    J Prosthet Dent; 2002 Jul; 88(1):37-43. PubMed ID: 12239478
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Effect of light source position and bevel placement on facial margin adaptation of resin-based composite restorations.
    Hoelscher DC; Gregory WA; Linger JB; Pink FE
    Am J Dent; 2000 Aug; 13(4):171-5. PubMed ID: 11763925
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 6.