These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
163 related articles for article (PubMed ID: 22182425)
1. Evaluation of coronary blood flow velocity during cardiac arrest with circulation maintained through mechanical chest compressions in a porcine model. Wagner H; Madsen Hardig B; Steen S; Sjoberg T; Harnek J; Olivecrona GK BMC Cardiovasc Disord; 2011 Dec; 11():73. PubMed ID: 22182425 [TBL] [Abstract][Full Text] [Related]
2. Cardiac Arrest in the Cardiac Catheterization Laboratory: Combining Mechanical Chest Compressions and Percutaneous LV Assistance. Lotun K; Truong HT; Cha KC; Alsakka H; Gianotto-Oliveira R; Smith N; Rao P; Bien T; Chatelain S; Kern MC; Hsu CH; Zuercher M; Kern KB JACC Cardiovasc Interv; 2019 Sep; 12(18):1840-1849. PubMed ID: 31537284 [TBL] [Abstract][Full Text] [Related]
3. Adverse hemodynamic effects of interrupting chest compressions for rescue breathing during cardiopulmonary resuscitation for ventricular fibrillation cardiac arrest. Berg RA; Sanders AB; Kern KB; Hilwig RW; Heidenreich JW; Porter ME; Ewy GA Circulation; 2001 Nov; 104(20):2465-70. PubMed ID: 11705826 [TBL] [Abstract][Full Text] [Related]
4. The effects of epinephrine/norepinephrine on end-tidal carbon dioxide concentration, coronary perfusion pressure and pulmonary arterial blood flow during cardiopulmonary resuscitation. Lindberg L; Liao Q; Steen S Resuscitation; 2000 Jan; 43(2):129-40. PubMed ID: 10694173 [TBL] [Abstract][Full Text] [Related]
5. Improved hemodynamic performance with a novel chest compression device during treatment of in-hospital cardiac arrest. Timerman S; Cardoso LF; Ramires JA; Halperin H Resuscitation; 2004 Jun; 61(3):273-80. PubMed ID: 15172705 [TBL] [Abstract][Full Text] [Related]
6. Repeated epinephrine doses during prolonged cardiopulmonary resuscitation have limited effects on myocardial blood flow: a randomized porcine study. Wagner H; Götberg M; Madsen Hardig B; Rundgren M; Carlson J; Götberg M; Zughaft D; Erlinge D; Olivecrona GK BMC Cardiovasc Disord; 2014 Dec; 14():199. PubMed ID: 25528598 [TBL] [Abstract][Full Text] [Related]
7. Increased cortical cerebral blood flow with LUCAS; a new device for mechanical chest compressions compared to standard external compressions during experimental cardiopulmonary resuscitation. Rubertsson S; Karlsten R Resuscitation; 2005 Jun; 65(3):357-63. PubMed ID: 15919574 [TBL] [Abstract][Full Text] [Related]
8. Does prearrest adrenergic integrity affect pressor response? A comparison of epinephrine and vasopressin in a spontaneous ventricular fibrillation swine model. Youngquist ST; Shah A; McClung C; Thomas JL; Rosborough JP; Niemann JT Resuscitation; 2011 Feb; 82(2):228-31. PubMed ID: 21051132 [TBL] [Abstract][Full Text] [Related]
9. Left ventricular compressions improve return of spontaneous circulation and hemodynamics in a swine model of traumatic cardiopulmonary arrest. Anderson KL; Fiala KC; Castaneda MG; Boudreau SM; Araña AA; Bebarta VS J Trauma Acute Care Surg; 2018 Aug; 85(2):303-310. PubMed ID: 29613954 [TBL] [Abstract][Full Text] [Related]
10. A comparison of 2 types of chest compressions in a porcine model of cardiac arrest. Wu JY; Li CS; Liu ZX; Wu CJ; Zhang GC Am J Emerg Med; 2009 Sep; 27(7):823-9. PubMed ID: 19683111 [TBL] [Abstract][Full Text] [Related]
11. Left Ventricular Compressions Improve Hemodynamics in a Swine Model of Out-of-Hospital Cardiac Arrest. Anderson KL; Castaneda MG; Boudreau SM; Sharon DJ; Bebarta VS Prehosp Emerg Care; 2017; 21(2):272-280. PubMed ID: 27918847 [TBL] [Abstract][Full Text] [Related]
12. Cardiac output, coronary blood flow, and blood gases during open-chest standard and compression-active-decompression cardiopulmonary resuscitation. Engoren M; Severyn F; Fenn-Buderer N; DeFrank M Resuscitation; 2002 Dec; 55(3):309-16. PubMed ID: 12458068 [TBL] [Abstract][Full Text] [Related]
13. Minimal interruption of cardiopulmonary resuscitation for a single shock as mandated by automated external defibrillations does not compromise outcomes in a porcine model of cardiac arrest and resuscitation. Ristagno G; Tang W; Russell JK; Jorgenson D; Wang H; Sun S; Weil MH Crit Care Med; 2008 Nov; 36(11):3048-53. PubMed ID: 18824916 [TBL] [Abstract][Full Text] [Related]
14. Coronary versus carotid blood flow and coronary perfusion pressure in a pig model of prolonged cardiac arrest treated by different modes of venoarterial ECMO and intraaortic balloon counterpulsation. Bělohlávek J; Mlček M; Huptych M; Svoboda T; Havránek S; Ošt'ádal P; Bouček T; Kovárník T; Mlejnský F; Mrázek V; Bělohlávek M; Aschermann M; Linhart A; Kittnar O Crit Care; 2012 Dec; 16(2):R50. PubMed ID: 22424292 [TBL] [Abstract][Full Text] [Related]
15. Miniaturized mechanical chest compressor: a new option for cardiopulmonary resuscitation. Ristagno G; Castillo C; Tang W; Sun S; Bisera J; Weil MH Resuscitation; 2008 Feb; 76(2):191-7. PubMed ID: 17728044 [TBL] [Abstract][Full Text] [Related]
16. Corpuls CPR Generates Higher Mean Arterial Pressure Than LUCAS II in a Pig Model of Cardiac Arrest. Eichhorn S; Mendoza A; Prinzing A; Stroh A; Xinghai L; Polski M; Heller M; Lahm H; Wolf E; Lange R; Krane M Biomed Res Int; 2017; 2017():5470406. PubMed ID: 29392137 [TBL] [Abstract][Full Text] [Related]
17. Retrograde coronary blood flow during cardiopulmonary resuscitation in swine: intracoronary Doppler evaluation. Kern KB; Hilwig R; Ewy GA Am Heart J; 1994 Sep; 128(3):490-9. PubMed ID: 8074010 [TBL] [Abstract][Full Text] [Related]
18. Feasibility of initiating extracorporeal life support during mechanical chest compression CPR: a porcine pilot study. Menegazzi JJ; Salcido DD; Housler GJ; Logue ES Resuscitation; 2012 Jan; 83(1):130-3. PubMed ID: 21835144 [TBL] [Abstract][Full Text] [Related]
20. Left ventricular thrombus development during ventricular fibrillation and resolution during resuscitation in a swine model of sudden cardiac arrest. Budhram GR; Mader TJ; Lutfy L; Murman D; Almulhim A Resuscitation; 2014 May; 85(5):689-93. PubMed ID: 24518559 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]