These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

95 related articles for article (PubMed ID: 22188538)

  • 1. Two different days of transcranial Doppler examinations should be performed for detection of right-to-left shunt in acute stroke patients.
    Aoki J; Kimura K; Iguchi Y; Sakai K; Sakamoto Y; Terasawa Y; Shibazaki K; Kobayashi K
    J Neuroimaging; 2013 Apr; 23(2):175-9. PubMed ID: 22188538
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Almost perfect concordance between simultaneous transcranial Doppler and transesophageal echocardiography in the quantification of right-to-left shunts.
    Belvís R; Leta RG; Martí-Fàbregas J; Cocho D; Carreras F; Pons-Lladó G; Martí-Vilalta JL
    J Neuroimaging; 2006 Apr; 16(2):133-8. PubMed ID: 16629735
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Detection of right-to-left shunt with ultrasound contrast agent and transcranial Doppler sonography.
    Jauss M; Zanette E
    Cerebrovasc Dis; 2000; 10(6):490-6. PubMed ID: 11070388
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Transcranial Doppler with bubble study as a method to detect extracardiac right-to-left shunts in patients with ischemic stroke.
    Goutman SA; Katzan IL; Gupta R
    J Neuroimaging; 2013 Oct; 23(4):523-5. PubMed ID: 22928688
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Contrast transcranial doppler ultrasound in the detection of right-to-left shunts : time window and threshold in microbubble numbers.
    Droste DW; Silling K; Stypmann J; Grude M; Kemény V; Wichter T; Kühne K; Ringelstein EB
    Stroke; 2000 Jul; 31(7):1640-5. PubMed ID: 10884466
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Safety of transcranial Doppler 'bubble study' for identification of right to left shunts: an international multicentre study.
    Tsivgoulis G; Stamboulis E; Sharma VK; Heliopoulos I; Voumvourakis K; Teoh HL; Vadikolias K; Triantafyllou N; Chan BP; Vasdekis SN; Piperidou C
    J Neurol Neurosurg Psychiatry; 2011 Nov; 82(11):1206-8. PubMed ID: 20971751
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Optimizing the technique of contrast transcranial Doppler ultrasound in the detection of right-to-left shunts.
    Droste DW; Lakemeier S; Wichter T; Stypmann J; Dittrich R; Ritter M; Moeller M; Freund M; Ringelstein EB
    Stroke; 2002 Sep; 33(9):2211-6. PubMed ID: 12215589
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Contrast-enhanced transcranial Doppler ultrasound for diagnosis of patent foramen ovale.
    Nedeltchev K; Mattle HP
    Front Neurol Neurosci; 2006; 21():206-215. PubMed ID: 17290139
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Different Valsalva Manoeuvre Procedures for the Diagnosis of Right-to-Left Shunt by Contrast-Transcranial Doppler.
    Liu C; Lu T; Zhai NN; Bu N; Wang HQ; Chen MY; Wu HQ
    Ultrasound Med Biol; 2017 Aug; 43(8):1716-1721. PubMed ID: 28545857
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Transcranial Doppler: Does Addition of Blood to Agitated Saline Affect Sensitivity for Detecting Cardiac Right-to-Left Shunt?
    Mojadidi MK; Zhang L; Chugh Y; Eshtehardi P; Hovnanians N; Gevorgyan R; Mojaddedi S; Nezami N; Zaman MO; Rafique A; Villablanca PA; Tobis JM
    Echocardiography; 2016 Aug; 33(8):1219-27. PubMed ID: 27095475
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Right-to-left shunt assessed by contrast transcranial Doppler sonography: new insights.
    Uzuner N; Horner S; Pichler G; Svetina D; Niederkorn K
    J Ultrasound Med; 2004 Nov; 23(11):1475-82. PubMed ID: 15498912
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Contrast transcranial Doppler ultrasound in the detection of right-to-left shunts: comparison of Echovist-200 and Echovist-300, timing of the Valsalva maneuver, and general recommendations for the performance of the test.
    Droste DW; Jekentaite R; Stypmann J; Grude M; Hansberg T; Ritter M; Nabavi D; Nam EM; Dittrich R; Wichter T; Ringelstein EB
    Cerebrovasc Dis; 2002; 13(4):235-41. PubMed ID: 12011547
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Is inferior vena cava compression an alternative for valsalva maneuver in contrast-enhanced transcranial doppler?.
    He Y; Deng J; Tu J; Zhang H; Guo Y
    Echocardiography; 2020 Feb; 37(2):331-336. PubMed ID: 31786807
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Adding blood to agitated saline significantly improves detection of right-to-left shunt by contrast-transcranial color-coded duplex sonography.
    Gentile M; De Vito A; Azzini C; Tamborino C; Casetta I
    Ultrasound Med Biol; 2014 Nov; 40(11):2637-41. PubMed ID: 25220269
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Contrast transcranial Doppler can diagnose large patent foramen ovale.
    Kobayashi K; Iguchi Y; Kimura K; Okada Y; Terasawa Y; Matsumoto N; Sakai K; Aoki J; Shibazaki K
    Cerebrovasc Dis; 2009; 27(3):230-4. PubMed ID: 19176955
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Low sensitivity of the echocardiograph compared with contrast transcranial Doppler in right-to-left shunt].
    Martínez-Sánchez P; Medina-Báez J; Lara-Lara M; Oliva-Navarro J; Cazorla-García R; Ruiz-Ares G; Martínez-Martínez M; Fuentes B; Díez-Tejedor E
    Neurologia; 2012 Mar; 27(2):61-7. PubMed ID: 21889234
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Body positions in the diagnosis of right-to-left shunt by contrast transcranial Doppler.
    Han K; Xing Y; Yang Y; Chao AC; Sheng WY; Hu HH; Wu J
    Ultrasound Med Biol; 2015 Sep; 41(9):2376-81. PubMed ID: 26067785
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Right-to-left-shunt detected by c-TCD using the orbital window in comparison with temporal bone windows.
    Kobayashi K; Kimura K; Iguchi Y; Sakai K; Aoki J; Iwanaga T; Shibazaki K
    J Neuroimaging; 2012 Jan; 22(1):80-4. PubMed ID: 21143546
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Right-to-left shunt detection using contrast-enhanced transcranial Doppler: A comparison of provocation maneuvers between coughing and a modified Valsalva maneuver.
    Wang SB; Wang XC; Ma Y; Liu KD; Xing YQ
    PLoS One; 2017; 12(4):e0175049. PubMed ID: 28384297
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Comparison of Different Methods of Valsalva Maneuver for Right-to-left Shunt Detection by Contrast-Enhanced Transcranial Doppler.
    Guo YZ; Gao YS; Guo ZN; Niu PP; Yang Y; Xing YQ
    Ultrasound Med Biol; 2016 May; 42(5):1124-9. PubMed ID: 26928233
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.