1. Very late stent thrombosis immediately after recurrent inappropriate shock delivery by an implantable cardioverter defibrillator. Groarke J; Phelan D; Burke D; Crean P; Foley B J Electrocardiol; 2012; 45(3):333-5. PubMed ID: 22197106 [TBL] [Abstract][Full Text] [Related]
2. Renal artery thrombosis following an inappropriate implantable cardioverter defibrillator shock. Arias MA; DE LA Rosa C; Puchol A; Rodríguez-Padial L Pacing Clin Electrophysiol; 2012 Sep; 35(9):e263-4. PubMed ID: 21797905 [TBL] [Abstract][Full Text] [Related]
3. Inappropriate implantable cardioverter defibrillator shocks in fractured Sprint Fidelis leads associated with 'appropriate' interrogation. Farwell D; Redpath C; Birnie D; Gollob M; Lemery R; Posan E; Green M Europace; 2008 Jun; 10(6):726-8. PubMed ID: 18456645 [TBL] [Abstract][Full Text] [Related]
4. Biventricular implantable cardioverter defibrillator right ventricle pace-sense ring electrode failure: lead switch fix. Venkataraman G; Moore H; Karasik P; Singh S; Fletcher R Pacing Clin Electrophysiol; 2008 Jul; 31(7):899-903. PubMed ID: 18684289 [TBL] [Abstract][Full Text] [Related]
5. Prevention of inappropriate ICD shocks due to lead insulation failure by continuous monitoring and automatic alert. Gelder RN; Gunderson BD Pacing Clin Electrophysiol; 2012 Jun; 35(6):e150-3. PubMed ID: 22309317 [TBL] [Abstract][Full Text] [Related]
6. Automatic R-wave and impedance testing with the modern patient alert system to reduce inappropriate implantable cardioverter defibrillator shocks due to lead fracture. Chinushi M; Hosaka Y; Ikarashi N; Iijima K; Furushima H; Aizawa Y Europace; 2008 Jun; 10(6):738-40. PubMed ID: 18390874 [TBL] [Abstract][Full Text] [Related]
7. "Magnetic attraction" in the pediatric emergency department: the case of a malfunctioning implantable cardioverter-defibrillator. Ladouceur VB; Khairy P; Béland MJ; Bhanji F Pediatr Emerg Care; 2012 Jun; 28(6):562-5. PubMed ID: 22668661 [TBL] [Abstract][Full Text] [Related]
8. Myocardial injury secondary to ICD shocks: insights from patients with lead fracture. Sham'a RA; Nery P; Sadek M; Yung D; Redpath C; Perrin M; Sarak B; Birnie D Pacing Clin Electrophysiol; 2014 Feb; 37(2):237-41. PubMed ID: 23998856 [TBL] [Abstract][Full Text] [Related]
9. Pacing-dependency following implantable cardioverter-defibrillator shocks: a case report. Webber MR; Levings SL; Stiles MK J Electrocardiol; 2013; 46(2):142-4. PubMed ID: 23177276 [TBL] [Abstract][Full Text] [Related]
10. Inappropriate shock delivery by implantable cardioverter defibrillator due to electrical interference with washing machine. Chongtham DS; Bahl A; Kumar RM; Talwar KK Int J Cardiol; 2007 May; 118(2):e44-5. PubMed ID: 17395291 [TBL] [Abstract][Full Text] [Related]
11. Lead integrity alert algorithm decreases inappropriate shocks in patients who have Sprint Fidelis pace-sense conductor fractures. Kallinen LM; Hauser RG; Tang C; Melby DP; Almquist AK; Katsiyiannis WT; Gornick CC Heart Rhythm; 2010 Aug; 7(8):1048-55. PubMed ID: 20493965 [TBL] [Abstract][Full Text] [Related]
13. Inappropriate ICD discharges due to noise oversensing as the first sign of repetitive perforations of the right ventricular lead. Ueda-Tatsumoto A; Fukamizu S; Nishizaki M; Sakurada H; Hiraoka M Pacing Clin Electrophysiol; 2009 Nov; 32(11):1481-4. PubMed ID: 19712072 [TBL] [Abstract][Full Text] [Related]
14. Phantom shocks in patients with an implantable cardioverter defibrillator. Juan EA; Pollack M J Emerg Med; 2010 Jan; 38(1):22-4. PubMed ID: 18394854 [TBL] [Abstract][Full Text] [Related]
15. A life-threatening arrhythmia induced by inappropriate activation of an implantable cardioverter defibrillator. Kadmon E; Kusniec J; Strasberg B Europace; 2009 Dec; 11(12):1716-8. PubMed ID: 19762330 [TBL] [Abstract][Full Text] [Related]
16. Implantable cardioverter defibrillator storm: nursing care issues for patients and families. O'Brien MC; Langberg J; Valderrama AL; Kirkendoll K; Romeiko N; Dunbar SB Crit Care Nurs Clin North Am; 2005 Mar; 17(1):9-16, ix. PubMed ID: 15749396 [TBL] [Abstract][Full Text] [Related]
17. Inappropriate implantable cardioverter-defibrillator shocks and signal jammers: first report of a new interference. Amasyali B; Kilic A Int J Cardiol; 2014 Oct; 176(3):e96-7. PubMed ID: 25125021 [No Abstract] [Full Text] [Related]
18. Downloadable software algorithm reduces inappropriate shocks caused by implantable cardioverter-defibrillator lead fractures: a prospective study. Swerdlow CD; Gunderson BD; Ousdigian KT; Abeyratne A; Sachanandani H; Ellenbogen KA Circulation; 2010 Oct; 122(15):1449-55. PubMed ID: 20876433 [TBL] [Abstract][Full Text] [Related]
19. Predictors of fracture risk of a small caliber implantable cardioverter defibrillator lead. Ha AC; Vezi BZ; Keren A; Alanazi H; Gollob MH; Green MS; Lemery R; Nery PB; Posan E; Birnie DH Pacing Clin Electrophysiol; 2010 Apr; 33(4):437-43. PubMed ID: 19954500 [TBL] [Abstract][Full Text] [Related]
20. Inappropriate implantable cardioverter-defibrillator shocks in MADIT II: frequency, mechanisms, predictors, and survival impact. Daubert JP; Zareba W; Cannom DS; McNitt S; Rosero SZ; Wang P; Schuger C; Steinberg JS; Higgins SL; Wilber DJ; Klein H; Andrews ML; Hall WJ; Moss AJ; J Am Coll Cardiol; 2008 Apr; 51(14):1357-65. PubMed ID: 18387436 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]