These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

135 related articles for article (PubMed ID: 22197106)

  • 1. Very late stent thrombosis immediately after recurrent inappropriate shock delivery by an implantable cardioverter defibrillator.
    Groarke J; Phelan D; Burke D; Crean P; Foley B
    J Electrocardiol; 2012; 45(3):333-5. PubMed ID: 22197106
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Renal artery thrombosis following an inappropriate implantable cardioverter defibrillator shock.
    Arias MA; DE LA Rosa C; Puchol A; Rodríguez-Padial L
    Pacing Clin Electrophysiol; 2012 Sep; 35(9):e263-4. PubMed ID: 21797905
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Inappropriate implantable cardioverter defibrillator shocks in fractured Sprint Fidelis leads associated with 'appropriate' interrogation.
    Farwell D; Redpath C; Birnie D; Gollob M; Lemery R; Posan E; Green M
    Europace; 2008 Jun; 10(6):726-8. PubMed ID: 18456645
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Biventricular implantable cardioverter defibrillator right ventricle pace-sense ring electrode failure: lead switch fix.
    Venkataraman G; Moore H; Karasik P; Singh S; Fletcher R
    Pacing Clin Electrophysiol; 2008 Jul; 31(7):899-903. PubMed ID: 18684289
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Prevention of inappropriate ICD shocks due to lead insulation failure by continuous monitoring and automatic alert.
    Gelder RN; Gunderson BD
    Pacing Clin Electrophysiol; 2012 Jun; 35(6):e150-3. PubMed ID: 22309317
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Automatic R-wave and impedance testing with the modern patient alert system to reduce inappropriate implantable cardioverter defibrillator shocks due to lead fracture.
    Chinushi M; Hosaka Y; Ikarashi N; Iijima K; Furushima H; Aizawa Y
    Europace; 2008 Jun; 10(6):738-40. PubMed ID: 18390874
    [TBL] [Abstract][Full Text] [Related]  

  • 7. "Magnetic attraction" in the pediatric emergency department: the case of a malfunctioning implantable cardioverter-defibrillator.
    Ladouceur VB; Khairy P; Béland MJ; Bhanji F
    Pediatr Emerg Care; 2012 Jun; 28(6):562-5. PubMed ID: 22668661
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Myocardial injury secondary to ICD shocks: insights from patients with lead fracture.
    Sham'a RA; Nery P; Sadek M; Yung D; Redpath C; Perrin M; Sarak B; Birnie D
    Pacing Clin Electrophysiol; 2014 Feb; 37(2):237-41. PubMed ID: 23998856
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Pacing-dependency following implantable cardioverter-defibrillator shocks: a case report.
    Webber MR; Levings SL; Stiles MK
    J Electrocardiol; 2013; 46(2):142-4. PubMed ID: 23177276
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Inappropriate shock delivery by implantable cardioverter defibrillator due to electrical interference with washing machine.
    Chongtham DS; Bahl A; Kumar RM; Talwar KK
    Int J Cardiol; 2007 May; 118(2):e44-5. PubMed ID: 17395291
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Lead integrity alert algorithm decreases inappropriate shocks in patients who have Sprint Fidelis pace-sense conductor fractures.
    Kallinen LM; Hauser RG; Tang C; Melby DP; Almquist AK; Katsiyiannis WT; Gornick CC
    Heart Rhythm; 2010 Aug; 7(8):1048-55. PubMed ID: 20493965
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Downloadable algorithm to reduce inappropriate shocks caused by fractures of implantable cardioverter-defibrillator leads.
    Swerdlow CD; Gunderson BD; Ousdigian KT; Abeyratne A; Stadler RW; Gillberg JM; Patel AS; Ellenbogen KA
    Circulation; 2008 Nov; 118(21):2122-9. PubMed ID: 18981299
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Inappropriate ICD discharges due to noise oversensing as the first sign of repetitive perforations of the right ventricular lead.
    Ueda-Tatsumoto A; Fukamizu S; Nishizaki M; Sakurada H; Hiraoka M
    Pacing Clin Electrophysiol; 2009 Nov; 32(11):1481-4. PubMed ID: 19712072
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Phantom shocks in patients with an implantable cardioverter defibrillator.
    Juan EA; Pollack M
    J Emerg Med; 2010 Jan; 38(1):22-4. PubMed ID: 18394854
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A life-threatening arrhythmia induced by inappropriate activation of an implantable cardioverter defibrillator.
    Kadmon E; Kusniec J; Strasberg B
    Europace; 2009 Dec; 11(12):1716-8. PubMed ID: 19762330
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Implantable cardioverter defibrillator storm: nursing care issues for patients and families.
    O'Brien MC; Langberg J; Valderrama AL; Kirkendoll K; Romeiko N; Dunbar SB
    Crit Care Nurs Clin North Am; 2005 Mar; 17(1):9-16, ix. PubMed ID: 15749396
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Inappropriate implantable cardioverter-defibrillator shocks and signal jammers: first report of a new interference.
    Amasyali B; Kilic A
    Int J Cardiol; 2014 Oct; 176(3):e96-7. PubMed ID: 25125021
    [No Abstract]   [Full Text] [Related]  

  • 18. Downloadable software algorithm reduces inappropriate shocks caused by implantable cardioverter-defibrillator lead fractures: a prospective study.
    Swerdlow CD; Gunderson BD; Ousdigian KT; Abeyratne A; Sachanandani H; Ellenbogen KA
    Circulation; 2010 Oct; 122(15):1449-55. PubMed ID: 20876433
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Predictors of fracture risk of a small caliber implantable cardioverter defibrillator lead.
    Ha AC; Vezi BZ; Keren A; Alanazi H; Gollob MH; Green MS; Lemery R; Nery PB; Posan E; Birnie DH
    Pacing Clin Electrophysiol; 2010 Apr; 33(4):437-43. PubMed ID: 19954500
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Inappropriate implantable cardioverter-defibrillator shocks in MADIT II: frequency, mechanisms, predictors, and survival impact.
    Daubert JP; Zareba W; Cannom DS; McNitt S; Rosero SZ; Wang P; Schuger C; Steinberg JS; Higgins SL; Wilber DJ; Klein H; Andrews ML; Hall WJ; Moss AJ;
    J Am Coll Cardiol; 2008 Apr; 51(14):1357-65. PubMed ID: 18387436
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.