182 related articles for article (PubMed ID: 22198092)
1. Suppression of the cardiopulmonary resuscitation artefacts using the instantaneous chest compression rate extracted from the thoracic impedance.
Aramendi E; Ayala U; Irusta U; Alonso E; Eftestøl T; Kramer-Johansen J
Resuscitation; 2012 Jun; 83(6):692-8. PubMed ID: 22198092
[TBL] [Abstract][Full Text] [Related]
2. Chest compression rate feedback based on transthoracic impedance.
González-Otero DM; Ruiz de Gauna S; Ruiz J; Daya MR; Wik L; Russell JK; Kramer-Johansen J; Eftestøl T; Alonso E; Ayala U
Resuscitation; 2015 Aug; 93():82-8. PubMed ID: 26051811
[TBL] [Abstract][Full Text] [Related]
3. Feasibility of shock advice analysis during CPR through removal of CPR artefacts from the human ECG.
Eilevstjønn J; Eftestøl T; Aase SO; Myklebust H; Husøy JH; Steen PA
Resuscitation; 2004 May; 61(2):131-41. PubMed ID: 15135189
[TBL] [Abstract][Full Text] [Related]
4. Feasibility of automated rhythm assessment in chest compression pauses during cardiopulmonary resuscitation.
Ruiz J; Ayala U; Ruiz de Gauna S; Irusta U; González-Otero D; Alonso E; Kramer-Johansen J; Eftestøl T
Resuscitation; 2013 Sep; 84(9):1223-8. PubMed ID: 23402965
[TBL] [Abstract][Full Text] [Related]
5. Transthoracic impedance used to evaluate performance of cardiopulmonary resuscitation during out of hospital cardiac arrest.
Stecher FS; Olsen JA; Stickney RE; Wik L
Resuscitation; 2008 Dec; 79(3):432-7. PubMed ID: 19061785
[TBL] [Abstract][Full Text] [Related]
6. A least mean-square filter for the estimation of the cardiopulmonary resuscitation artifact based on the frequency of the compressions.
Irusta U; Ruiz J; de Gauna SR; Eftestøl T; Kramer-Johansen J
IEEE Trans Biomed Eng; 2009 Apr; 56(4):1052-62. PubMed ID: 19150778
[TBL] [Abstract][Full Text] [Related]
7. An investigation of thrust, depth and the impedance cardiogram as measures of cardiopulmonary resuscitation efficacy in a porcine model of cardiac arrest.
Howe A; O'Hare P; Crawford P; Delafont B; McAlister O; Di Maio R; Clutton E; Adgey J; McEneaney D
Resuscitation; 2015 Nov; 96():114-20. PubMed ID: 26234892
[TBL] [Abstract][Full Text] [Related]
8. Fully automatic rhythm analysis during chest compression pauses.
Ayala U; Irusta U; Ruiz J; Ruiz de Gauna S; González-Otero D; Alonso E; Kramer-Johansen J; Naas H; Eftestøl T
Resuscitation; 2015 Apr; 89():25-30. PubMed ID: 25619441
[TBL] [Abstract][Full Text] [Related]
9. Reliability and accuracy of the thoracic impedance signal for measuring cardiopulmonary resuscitation quality metrics.
Alonso E; Ruiz J; Aramendi E; González-Otero D; Ruiz de Gauna S; Ayala U; Russell JK; Daya M
Resuscitation; 2015 Mar; 88():28-34. PubMed ID: 25524362
[TBL] [Abstract][Full Text] [Related]
10. Minimizing pre-shock chest compression pauses in a cardiopulmonary resuscitation cycle by performing an earlier rhythm analysis.
Steinberg MT; Olsen JA; Brunborg C; Persse D; Sterz F; Lozano M; Brouwer MA; Westfall M; Souders CM; van Grunsven PM; Travis DT; Lerner EB; Wik L
Resuscitation; 2015 Feb; 87():33-7. PubMed ID: 25461493
[TBL] [Abstract][Full Text] [Related]
11. A method to remove CPR artefacts from human ECG using only the recorded ECG.
Ruiz de Gauna S; Ruiz J; Irusta U; Aramendi E; Eftestøl T; Kramer-Johansen J
Resuscitation; 2008 Feb; 76(2):271-8. PubMed ID: 17875356
[TBL] [Abstract][Full Text] [Related]
12. Automatic detection of chest compressions for the assessment of CPR-quality parameters.
Ayala U; Eftestøl T; Alonso E; Irusta U; Aramendi E; Wali S; Kramer-Johansen J
Resuscitation; 2014 Jul; 85(7):957-63. PubMed ID: 24746788
[TBL] [Abstract][Full Text] [Related]
13. Transthoracic impedance for the monitoring of quality of manual chest compression during cardiopulmonary resuscitation.
Zhang H; Yang Z; Huang Z; Chen B; Zhang L; Li H; Wu B; Yu T; Li Y
Resuscitation; 2012 Oct; 83(10):1281-6. PubMed ID: 22828357
[TBL] [Abstract][Full Text] [Related]
14. Strong corruption of electrocardiograms caused by cardiopulmonary resuscitation reduces efficiency of two-channel methods for removing motion artefacts in non-shockable rhythms.
Werther T; Klotz A; Granegger M; Baubin M; Feichtinger HG; Amann A; Gilly H
Resuscitation; 2009 Nov; 80(11):1301-7. PubMed ID: 19735967
[TBL] [Abstract][Full Text] [Related]
15. Filtering mechanical chest compression artefacts from out-of-hospital cardiac arrest data.
Aramendi E; Irusta U; Ayala U; Naas H; Kramer-Johansen J; Eftestøl T
Resuscitation; 2016 Jan; 98():41-7. PubMed ID: 26546986
[TBL] [Abstract][Full Text] [Related]
16. Identifying potentially shockable rhythms without interrupting cardiopulmonary resuscitation.
Li Y; Bisera J; Geheb F; Tang W; Weil MH
Crit Care Med; 2008 Jan; 36(1):198-203. PubMed ID: 18090359
[TBL] [Abstract][Full Text] [Related]
17. Performance of chest compressions by laypersons during the Public Access Defibrillation Trial.
Rea TD; Stickney RE; Doherty A; Lank P
Resuscitation; 2010 Mar; 81(3):293-6. PubMed ID: 20044198
[TBL] [Abstract][Full Text] [Related]
18. A Method to Detect Presence of Chest Compressions During Resuscitation Using Transthoracic Impedance.
Coult J; Blackwood J; Rea TD; Kudenchuk PJ; Kwok H
IEEE J Biomed Health Inform; 2020 Mar; 24(3):768-774. PubMed ID: 31144648
[TBL] [Abstract][Full Text] [Related]
19. Assessment of CPR interruptions from transthoracic impedance during use of the LUCAS™ mechanical chest compression system.
Yost D; Phillips RH; Gonzales L; Lick CJ; Satterlee P; Levy M; Barger J; Dodson P; Poggi S; Wojcik K; Niskanen RA; Chapman FW
Resuscitation; 2012 Aug; 83(8):961-5. PubMed ID: 22310728
[TBL] [Abstract][Full Text] [Related]
20. Rhythm discrimination during uninterrupted CPR using motion artifact reduction system.
Berger RD; Palazzolo J; Halperin H
Resuscitation; 2007 Oct; 75(1):145-52. PubMed ID: 17467872
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]