These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
53 related articles for article (PubMed ID: 22200475)
1. Evaluation of an annular denuder/filter pack system to collect acidic aerosols and gases. Koutrakis P; Wolfson JM; Slater JL; Brauer M; Spengler JD; Stevens RK; Stone CL Environ Sci Technol; 1988 Dec; 22(12):1463-8. PubMed ID: 22200475 [No Abstract] [Full Text] [Related]
2. Use of two different acidic aerosol samplers to measure acidic aerosols in Hsinchu, Taiwan. Tsai CJ; Perng SB; Chiou SF J Air Waste Manag Assoc; 2000 Dec; 50(12):2120-8. PubMed ID: 11153491 [TBL] [Abstract][Full Text] [Related]
3. Annular diffusion denuder for simultaneous removal of gaseous organic compounds and air oxidants during sampling of carbonaceous aerosols. Mikuška P; Večeřa Z; Bartošíková A; Maenhaut W Anal Chim Acta; 2012 Feb; 714():68-75. PubMed ID: 22244138 [TBL] [Abstract][Full Text] [Related]
4. Dichotomous sampling of vapor and aerosol of methylene-bis-(phenylisocyanate) [MDI] with an annular diffusional denuder. Rando RJ; Poovey HG Am Ind Hyg Assoc J; 1994 Aug; 55(8):716-21. PubMed ID: 7942508 [TBL] [Abstract][Full Text] [Related]
5. Size-separated sampling and analysis of isocyanates in workplace aerosols. Part I. Denuder--cascade impactor sampler. Dahlin J; Spanne M; Karlsson D; Dalene M; Skarping G Ann Occup Hyg; 2008 Jul; 52(5):361-74. PubMed ID: 18458354 [TBL] [Abstract][Full Text] [Related]
6. Measurement of semivolatile carbonaceous aerosols and its implications: a review. Cheng Y; He KB; Duan FK; Zheng M; Ma YL; Tan JH Environ Int; 2009 Apr; 35(3):674-81. PubMed ID: 19201473 [TBL] [Abstract][Full Text] [Related]
7. Characteristics of atmospheric aerosol and acidic gases from urban and forest sites in central taiwan. Cheng MT; Horng CL; Lin YC Bull Environ Contam Toxicol; 2007 Dec; 79(6):674-7. PubMed ID: 17962896 [TBL] [Abstract][Full Text] [Related]
8. Development and evaluation of a countercurrent parallel-plate membrane diffusion denuder for the removal of gas-phase compounds from vehicular emissions. Papapostolou V; Lawrence JE; Ferguson ST; Wolfson JM; Koutrakis P Inhal Toxicol; 2011 Nov; 23(13):853-62. PubMed ID: 22035125 [TBL] [Abstract][Full Text] [Related]
9. Membrane-based parallel plate denuder for the collection and removal of soluble atmospheric gases. Takeuchi M; Li J; Morris KJ; Dasgupta PK Anal Chem; 2004 Feb; 76(4):1204-10. PubMed ID: 14961756 [TBL] [Abstract][Full Text] [Related]
10. Denuder sampling techniques for the determination of gas-phase carbonyl compounds: a comparison and characterisation of in situ and ex situ derivatisation methods. Kahnt A; Iinuma Y; Böge O; Mutzel A; Herrmann H J Chromatogr B Analyt Technol Biomed Life Sci; 2011 May; 879(17-18):1402-11. PubMed ID: 21411383 [TBL] [Abstract][Full Text] [Related]
11. [Study on the isolation method for the different states of atmospheric pollutant]. Wu Y Wei Sheng Yan Jiu; 1999 Nov; 28(6):341-2. PubMed ID: 12016985 [TBL] [Abstract][Full Text] [Related]
12. Evaluation of a personal and microenvironmental aerosol speciation sampler (PMASS). Geyh AS; Hering S; Kreisberg N; John W Res Rep Health Eff Inst; 2004 Nov; (122):1-22; discussion 23-9. PubMed ID: 15675716 [TBL] [Abstract][Full Text] [Related]
13. Comparison of annular diffusion denuder and high volume air samplers for measuring per- and polyfluoroalkyl substances in the atmosphere. Ahrens L; Shoeib M; Harner T; Lane DA; Guo R; Reiner EJ Anal Chem; 2011 Dec; 83(24):9622-8. PubMed ID: 22066738 [TBL] [Abstract][Full Text] [Related]
14. Development of a coupled diffusion denuder system combined with gas chromatography/mass spectrometry for the separation and quantification of molecular iodine and the activated iodine compounds iodine monochloride and hypoiodous acid in the marine atmosphere. Huang RJ; Hoffmann T Anal Chem; 2009 Mar; 81(5):1777-83. PubMed ID: 19199811 [TBL] [Abstract][Full Text] [Related]
15. On the deposition of volatiles and semivolatiles from cigarette smoke aerosols: relative rates of transfer of nicotine and ammonia from particles to the gas phase. Seeman JI; Lipowicz PJ; Piadé JJ; Poget L; Sanders EB; Snyder JP; Trowbridge CG Chem Res Toxicol; 2004 Aug; 17(8):1020-37. PubMed ID: 15310234 [TBL] [Abstract][Full Text] [Related]
16. Performance of a high flow rate, thermally extractable multicapillary denuder for atmospheric semivolatile organic compound concentration measurement. Rowe MD; Perlinger JA Environ Sci Technol; 2010 Mar; 44(6):2098-104. PubMed ID: 20148550 [TBL] [Abstract][Full Text] [Related]
17. Development and application of a dichotomous vapor/aerosol sampler for HDI-derived total reactive isocyanate group. Rando RJ; Poovey HG Am Ind Hyg Assoc J; 1999; 60(6):737-46. PubMed ID: 10635539 [TBL] [Abstract][Full Text] [Related]
18. Gas collection efficiency of annular denuders: a spreadsheet-based calculator. Berg JM; James DL; Berg CF; Toda K; Dasgupta PK Anal Chim Acta; 2010 Apr; 664(1):56-61. PubMed ID: 20226932 [TBL] [Abstract][Full Text] [Related]
19. Size-separated sampling and analysis of isocyanates in workplace aerosols--Part II: aging of aerosols from thermal degradation of polyurethane. Dahlin J; Spanne M; Dalene M; Karlsson D; Skarping G Ann Occup Hyg; 2008 Jul; 52(5):375-83. PubMed ID: 18448445 [TBL] [Abstract][Full Text] [Related]
20. A new method for the measurement of trace amounts of HONO in the atmosphere using an air-dragged aqua-membrane-type denuder and fluorescence detection. Takenaka N; Terada H; Oro Y; Hiroi M; Yoshikawa H; Okitsu K; Bandow H Analyst; 2004 Nov; 129(11):1130-6. PubMed ID: 15508044 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]