172 related articles for article (PubMed ID: 22203047)
1. Biomechanical stability of different suture fixation techniques for tibial eminence fractures.
Schneppendahl J; Thelen S; Gehrmann S; Twehues S; Eichler C; Koebke J; Windolf J; Hakimi M; Wild M
Knee Surg Sports Traumatol Arthrosc; 2012 Oct; 20(10):2092-7. PubMed ID: 22203047
[TBL] [Abstract][Full Text] [Related]
2. Suture versus screw fixation of displaced tibial eminence fractures: a biomechanical comparison.
Bong MR; Romero A; Kubiak E; Iesaka K; Heywood CS; Kummer F; Rosen J; Jazrawi L
Arthroscopy; 2005 Oct; 21(10):1172-6. PubMed ID: 16226643
[TBL] [Abstract][Full Text] [Related]
3. Arthroscopic Fixation of Tibial Eminence Fractures: A Biomechanical Comparative Study of Screw, Suture, and Suture Anchor.
Li J; Yu Y; Liu C; Su X; Liao W; Li Z
Arthroscopy; 2018 May; 34(5):1608-1616. PubMed ID: 29397286
[TBL] [Abstract][Full Text] [Related]
4. Biomechanical evaluation of physeal-sparing fixation methods in tibial eminence fractures.
Anderson CN; Nyman JS; McCullough KA; Song Y; Uppuganti S; O'Neill KR; Anderson AF; Dunn WR
Am J Sports Med; 2013 Jul; 41(7):1586-94. PubMed ID: 23690259
[TBL] [Abstract][Full Text] [Related]
5. Biomechanical comparison of tibial eminence fracture fixation with high-strength suture, EndoButton, and suture anchor.
Hapa O; Barber FA; Süner G; Özden R; Davul S; Bozdağ E; Sünbüloğlu E
Arthroscopy; 2012 May; 28(5):681-7. PubMed ID: 22284410
[TBL] [Abstract][Full Text] [Related]
6. The use of biodegradable sutures for the fixation of tibial eminence fractures in children: a comparison using PDS II, Vicryl and FiberWire.
Schneppendahl J; Thelen S; Twehues S; Eichler C; Betsch M; Windolf J; Hakimi M; Wild M
J Pediatr Orthop; 2013 Jun; 33(4):409-14. PubMed ID: 23653031
[TBL] [Abstract][Full Text] [Related]
7. Screws or Sutures? A Pediatric Cadaveric Study of Tibial Spine Fracture Repairs.
Johnstone TM; Baird DW; Cuellar-Montes A; van Deursen WH; Tompkins M; Ganley TJ; Yen YM; Ellis HB; Chan CK; Green DW; Sherman SL; Shea KG
Am J Sports Med; 2023 Aug; 51(10):2589-2595. PubMed ID: 37382335
[TBL] [Abstract][Full Text] [Related]
8. Biomechanical analysis of suture bridge fixation for tibial eminence fractures.
Sawyer GA; Anderson BC; Paller D; Schiller J; Eberson CP; Hulstyn M
Arthroscopy; 2012 Oct; 28(10):1533-9. PubMed ID: 22607830
[TBL] [Abstract][Full Text] [Related]
9. [BIOMECHANICAL STUDY ON SUTURE WITH NECKWEAR-KNOT-LOOP-LIGATURE FOR TIBIAL EMINENCE AVULSION FRACTURES].
Wang J; Shen X; Liu C; Qi W; Qu F; Yuan B; Zhao G; Guo Q; Li H; Lu X; Zhu J; Liu Y; Liu Y
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2015 Sep; 29(9):1080-3. PubMed ID: 26750003
[TBL] [Abstract][Full Text] [Related]
10. Arthroscopic suture fixation of tibial eminence fractures.
Shook JB; Frank HG; Freedman KB
Orthopedics; 2006 Jul; 29(7):577-81. PubMed ID: 16866087
[No Abstract] [Full Text] [Related]
11. Suture versus screw fixation technique for tibial eminence fracture: A meta-analysis of laboratory studies.
Ye M; Chen J; Hu F; Liu Y; Tan Y
J Orthop Surg (Hong Kong); 2020; 28(1):2309499020907977. PubMed ID: 32124674
[TBL] [Abstract][Full Text] [Related]
12. [Effectiveness of arthroscopic treatment of anterior cruciate ligament tibial eminence avulsion fracture with non-absorbable suture fixation combined with mini-plate].
Wang S; Xiao Y; Tong Z; Li G; Jiang J; Yao J; Wu Z; Li T; Wu Q
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2013 Sep; 27(9):1041-4. PubMed ID: 24279010
[TBL] [Abstract][Full Text] [Related]
13. Tension band wire fixation for anterior cruciate ligament avulsion fracture: biomechanical comparison of four fixation techniques.
Gan Y; Xu D; Ding J; Xu Y
Knee Surg Sports Traumatol Arthrosc; 2012 May; 20(5):909-15. PubMed ID: 21863305
[TBL] [Abstract][Full Text] [Related]
14. Biomechanical comparison of four different fixation techniques for pediatric tibial eminence avulsion fractures.
Mahar AT; Duncan D; Oka R; Lowry A; Gillingham B; Chambers H
J Pediatr Orthop; 2008 Mar; 28(2):159-62. PubMed ID: 18388708
[TBL] [Abstract][Full Text] [Related]
15. [EFFECTIVENESS OF ARTHROSCOPIC ULTRA-Braid SUTURE PLANE FIXATION FOR ANTERIOR CRUCIATE LIGAMENT TIBIAL EMINENCE AVULSION FRACTURES].
Wang J; Weng X; Li J; Chen X
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2015 Nov; 29(11):1353-7. PubMed ID: 26875266
[TBL] [Abstract][Full Text] [Related]
16. Arthroscopic suture fixation of tibial spine fractures.
Alakkas E; Drager J; Kerrigan A; Carsen S
J ISAKOS; 2024 Jun; 9(3):415-417. PubMed ID: 38518894
[TBL] [Abstract][Full Text] [Related]
17. Absorbable and non-absorbable suture fixation results in similar outcomes for tibial eminence fractures in children and adolescents.
Brunner S; Vavken P; Kilger R; Vavken J; Rutz E; Brunner R; Camathias C
Knee Surg Sports Traumatol Arthrosc; 2016 Mar; 24(3):723-9. PubMed ID: 26520645
[TBL] [Abstract][Full Text] [Related]
18. Bioabsorbable sutures versus screw fixation of displaced tibial eminence fractures: a biomechanical study.
Senekovic V; Balazic M
Eur J Orthop Surg Traumatol; 2014 Feb; 24(2):209-16. PubMed ID: 23412317
[TBL] [Abstract][Full Text] [Related]
19. Biomechanical evaluation of tibial eminence fractures using suture fixation.
Aoki SK; Curtis SH
Orthopedics; 2011 Dec; 34(12):e866-70. PubMed ID: 22146203
[TBL] [Abstract][Full Text] [Related]
20. The most economical arthroscopic suture fixation for tibial intercondylar eminence avulsion fracture without any implant.
Yuan L; Shi R; Chen Z; Ding W; Tan H
J Orthop Surg Res; 2022 Jun; 17(1):327. PubMed ID: 35752828
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]