214 related articles for article (PubMed ID: 22205600)
1. Microkeratome-assisted preparation of ultrathin grafts for descemet stripping automated endothelial keratoplasty.
Busin M; Patel AK; Scorcia V; Ponzin D
Invest Ophthalmol Vis Sci; 2012 Jan; 53(1):521-4. PubMed ID: 22205600
[TBL] [Abstract][Full Text] [Related]
2. Single-Pass Microkeratome System for Eye Bank DSAEK Tissue Preparation: Is Stromal Bed Thickness Predictable and Reproducible?
Choulakian MY; Li JY; Ramos S; Mannis MJ
Cornea; 2016 Jan; 35(1):95-9. PubMed ID: 26555583
[TBL] [Abstract][Full Text] [Related]
3. Comparison of swollen and dextran deswollen organ-cultured corneas for Descemet membrane dissection preparation: histological and ultrastructural findings.
Yoeruek E; Hofmann J; Bartz-Schmidt KU
Invest Ophthalmol Vis Sci; 2013 Dec; 54(13):8036-40. PubMed ID: 24159091
[TBL] [Abstract][Full Text] [Related]
4. Postoperative Graft Thickness Obtained With Single-Pass Microkeratome-Assisted Ultrathin Descemet Stripping Automated Endothelial Keratoplasty.
Nahum Y; Leon P; Busin M
Cornea; 2015 Nov; 34(11):1362-4. PubMed ID: 26356756
[TBL] [Abstract][Full Text] [Related]
5. Preparation of ultrathin grafts for Descemet-stripping endothelial keratoplasty with a single microkeratome pass.
Romano V; Steger B; Myneni J; Batterbury M; Willoughby CE; Kaye SB
J Cataract Refract Surg; 2017 Jan; 43(1):12-15. PubMed ID: 28317665
[TBL] [Abstract][Full Text] [Related]
6. Preconditioned donor corneal thickness for microthin endothelial keratoplasty.
Thomas PB; Mukherjee AN; O'Donovan D; Rajan MS
Cornea; 2013 Jul; 32(7):e173-8. PubMed ID: 23665648
[TBL] [Abstract][Full Text] [Related]
7. Descemet membrane endothelial keratoplasty tissue preparation from donor corneas using a standardized submerged hydro-separation method.
Parekh M; Ruzza A; Salvalaio G; Ferrari S; Camposampiero D; Busin M; Ponzin D
Am J Ophthalmol; 2014 Aug; 158(2):277-285.e1. PubMed ID: 24792104
[TBL] [Abstract][Full Text] [Related]
8. Single-Pass Dissection of Ultrathin Organ-Cultured Endothelial Lamellae Using an Innovative Microkeratome System.
Dickman MM; Kruit PJ; van den Biggelaar FJ; Berendschot TT; Nuijts RM
Cornea; 2016 Jan; 35(1):100-4. PubMed ID: 26555592
[TBL] [Abstract][Full Text] [Related]
9. Technique for Preparing Ultrathin and Nanothin Descemet Stripping Automated Endothelial Keratoplasty Tissue.
Cheung AY; Hou JH; Bedard P; Grimes V; Buckman N; Eslani M; Holland EJ
Cornea; 2018 May; 37(5):661-666. PubMed ID: 29329121
[TBL] [Abstract][Full Text] [Related]
10. Graft profile and thickness as a function of cut transition speed in Descemet-stripping automated endothelial keratoplasty.
Bhogal MS; Allan BD
J Cataract Refract Surg; 2012 Apr; 38(4):690-5. PubMed ID: 22440438
[TBL] [Abstract][Full Text] [Related]
11. Assessment of eye bank-prepared posterior lamellar corneal tissue for endothelial keratoplasty.
Rose L; Briceño CA; Stark WJ; Gloria DG; Jun AS
Ophthalmology; 2008 Feb; 115(2):279-86. PubMed ID: 17599413
[TBL] [Abstract][Full Text] [Related]
12. Single-Pass Mikrokeratome and Anterior Chamber Pressurizer for the Ultrathin Descemet-Stripping Automated Endothelial Keratoplasty Graft Preparation.
Clerici R; Ceccuzzi R; Fausto R; Tinelli C; Di Palma MR; Mantegna G; Riva I; Busin M; De Angelis G; Quaranta L
Cornea; 2021 Jun; 40(6):755-763. PubMed ID: 33630814
[TBL] [Abstract][Full Text] [Related]
13. Descemet stripping automated endothelial keratoplasty using infant donor tissue.
Kim P; Yeung SN; Lichtinger A; Amiran MD; Rootman DS
Cornea; 2012 Jan; 31(1):52-4. PubMed ID: 22157523
[TBL] [Abstract][Full Text] [Related]
14. Donor preparation using pneumatic dissection in endothelial keratoplasty: DMEK or DSEK?
McKee HD; Irion LC; Carley FM; Jhanji V; Brahma AK
Cornea; 2012 Jul; 31(7):798-800. PubMed ID: 22262221
[TBL] [Abstract][Full Text] [Related]
15. Combined use of a femtosecond laser and a microkeratome in obtaining thin grafts for Descemet stripping automated endothelial keratoplasty: an eye bank study.
Murta JN; Rosa AM; Quadrado MJ; Russo AD; Brito SS; Silva MF
Eur J Ophthalmol; 2013; 23(4):584-9. PubMed ID: 23564609
[TBL] [Abstract][Full Text] [Related]
16. Descemet membrane air-bubble separation in donor corneas.
Venzano D; Pagani P; Randazzo N; Cabiddu F; Traverso CE
J Cataract Refract Surg; 2010 Dec; 36(12):2022-7. PubMed ID: 21111302
[TBL] [Abstract][Full Text] [Related]
17. Endothelial cell density before and after the preparation of corneal lamellae for Descemet membrane endothelial keratoplasty with a stromal rim.
Krabcova I; Studeny P; Jirsova K
Cornea; 2011 Dec; 30(12):1436-41. PubMed ID: 21963859
[TBL] [Abstract][Full Text] [Related]
18. Precut tissue in Descemet's stripping automated endothelial keratoplasty donor characteristics and early postoperative complications.
Chen ES; Terry MA; Shamie N; Hoar KL; Friend DJ
Ophthalmology; 2008 Mar; 115(3):497-502. PubMed ID: 18221999
[TBL] [Abstract][Full Text] [Related]
19. Descemet-stripping automated endothelial keratoplasty donor tissue preparation using the double-pass microkeratome technique.
Waite A; Davidson R; Taravella MJ
J Cataract Refract Surg; 2013 Mar; 39(3):446-50. PubMed ID: 23506921
[TBL] [Abstract][Full Text] [Related]
20. Effect of microkeratome pass on tissue processing for Descemet stripping automated endothelial keratoplasty.
Woodward MA; Titus MS; Shtein RM
Cornea; 2014 May; 33(5):507-9. PubMed ID: 24619169
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]